5 Operation

Operation manual

9

ELSH/X(B)12P30+50E
Daikin Altherma 3 R MT ECH

O

4P708485-1 – 2023.01

5.3

Possible screens: Overview

The most common screens are as follows:

+

a

OR

b

c

c2

c4

c1

c3

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

c3

: Screen with weather-dependent curve

c4

: Screen with schedule

5.3.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

1.6

bar

26 Feb 2019

22:19

55

21
35

j

e2

l

k1
k2

k3

45

d

e1

g3

g2

h1

g1

f

i2 i3

i4

h2

i1

a2

a1

e3

b c

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

a Domestic hot water

a1

Domestic hot water

a2

55

Measured tank temperature

(a)

Item

Description

b Disinfection / Powerful

Disinfection mode active

Powerful operation mode active

c Emergency

Heat pump failure and system operates in

Emergency

 mode or heat pump is forced off.

d Current date and time

e Smart energy

e1

Smart energy is available via solar panels or smart
grid.

e2

Smart energy is currently being used for space
heating.

e3

Smart energy is currently being used for domestic
hot water.

f

Space operation mode

Cooling

Heating

g Outdoor / quiet mode

g1

6

Measured outdoor temperature

(a)

g2

Quiet mode active

g3

Outdoor unit

h Indoor unit / domestic hot water tank

h1

Floor-standing indoor unit with integrated tank

Wall-mounted indoor unit

Wall-mounted indoor unit with separated tank

h2

Water pressure

i

Main zone

i1

Installed room thermostat type:

Unit operation is decided based on the ambient
temperature of the dedicated Human Comfort
Interface (BRC1HHDA used as room thermostat).

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

i2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

i3

21

Measured room temperature

(a)

i4

35

Leaving water temperature setpoint

(a)

j

Holiday mode

Holiday mode active

Summary of Contents for Altherma 3 RMT ECH2O

Page 1: ...n manual Daikin Altherma 3 R MT ECH O English Operation manual Daikin Altherma 3 R MT ECH O ELSH12P30E ELSH12P50E ELSHB12P30E ELSHB12P50E ELSX12P30E ELSX12P50E ELSXB12P30E ELSXB12P50E 1 2 3 9 A B C Z...

Page 2: ...be filled in by installer 20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating th...

Page 3: ...nce Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT pla...

Page 4: ...ors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where yo...

Page 5: ...ernal room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2 2 Set operation to On or Off To change the de...

Page 6: ...e temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating coolin...

Page 7: ...e display Dials and buttons You use the dials and buttons To navigate through the screens menus and settings of the LCD screen To set values a b c d e Item Description a Left dial The LCD shows an arc...

Page 8: ...ar Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Mode Schedule Level 7 5 Electricity price High Medium Low Schedule 5 Tank Powerful operation Schedule 1 9 Room comf...

Page 9: ...p failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is current...

Page 10: ...symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temperature zones Shows the appl...

Page 11: ...tection Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature con...

Page 12: ...to the Operation mode schedule 4 2 To restrict automatic changeover according to a schedule Conditions You set the space operation mode to Automatic 1 Go to 4 2 Space heating cooling Operation mode s...

Page 13: ...perature drops below a preset value set temperature hysteresis value example 40 C the tank is heated up to 50 C During the afternoon and evening you consume hot water again and the DHW tank temperatur...

Page 14: ...day of which you want to clear the content For example Friday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 2 Select Delete Delete Edit Copy 3 Select OK to confirm To program the schedule for Monday 1...

Page 15: ...operation The unit operates weather dependent if the desired leaving water or tank temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor...

Page 16: ...temperature is heated increasingly more at decreasingly lower ambient temperatures Change the offset to equally increase or decrease the temperature of the leaving water for different ambient temperat...

Page 17: ...s how to fine tune the weather dependent curve of a zone or tank You feel Fine tune with slope and offset At regular outdoor temperatures At cold outdoor temperatures Slope Offset OK Cold You feel Fin...

Page 18: ...eater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that t...

Page 19: ...larly as in Manual mode the unit can take the full load with the backup heater or boiler if the user activates this via the Malfunctioning main menu screen When the heat pump fails or will appear on t...

Page 20: ...s 4 4 Solar 9 2 4 Backup heater Voltage 9 3 2 Configuration 9 3 3 Capacity step 1 9 3 4 Additional capacity step 2 9 3 5 if applicable EN20190625 Emitter type 2 7 Control 2 9 Setpoint mode 2 4 Schedul...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P708485 1 2023 01 Copyright 2023 Daikin 4P708485 1 0000000U Verantwortung f r Energie und Umwelt...

Reviews: