5 Technical data
Service manual
103
EBLQ+EDLQ011~W1 + EBLQ+EDLQ011~0W1
+ EK(2)CB EKMB9W1
Daikin Altherma – Monobloc
ESIE18-04 – 2019.02
English
Translation
A7P
*
Receiver PCB (wireless On/OFF
thermostat)
DS1 (A4P)
*
DIP switch
E4H
*
Booster heater (3 kW)
F1U
Fuse T 5 A 500 V
F1U (A4P)
Fuse T 2 A 250 V
F2B
*
Overcurrent fuse booster heater
F2U (A4P)
Fuse T 2 A 250 V for 3-way valve
K1A
Relay for heating
K1
*
Terminal strip
K2A
Relay for cooling
K2
*
Booster heater
K3M
*
Contactor booster heater
M2P
#
Domestic hot water pump
M2S
#
Shut-off valve
M3S
3-way valve for domestic hot
water
M4S
*
Valve kit
PC (A7P)
Power circuit
Q2L
*
Thermal protector booster heater
Q5DI, Q6DI
Earth leakage circuit breaker
R1H (A3P)
*
Humidity sensor
R1T (A3P)
*
Ambient sensor On/OFF
thermostat
R1T (A5P)
Ambient sensor user interface
R2T
*
External indoor floor/ambient
thermistor
R5T
*
Domestic hot water thermistor
S1S
#
Preferential kWh rate power
supply contact
STB
*
Thermal protector booster heater
X*A (A4P)
Connector
X*M
Terminal strip
*:
Optional
#:
Field supply
Control box option: backup heater
English
Translation
BUH option
Backup heater option
Control box
Control box
Only for ***
Only for ***
E1H
Backup heater element (1 kW)
E2H
Backup heater element (2 kW)
E3H
Backup heater element
F1B
*
Overcurrent fuse backup heater
English
Translation
F1T, F2T
*
Thermal fuse backup heater
F1U
Fuse T 5 A 500 V backup heater
option
K1M
*
Contactor backup heater (step 1)
K1R
*
Relay backup heater (step 1)
K2M
*
Contactor backup heater (step 2)
(only for *9W)
K2R
*
Relay backup heater (step 2)
(only for *9W)
K5M
*
Safety contactor backup heater
(only for *9W)
Q1DI
#
Earth leakage circuit breaker
Q1L
*
Thermal protector backup heater
R2T
*
Outlet backup heater thermistor
X*M
Terminal strip
*:
Optional
#:
Field supply
Control box option: option box
English
Translation
Alarm output
Alarm output
Control box
Control box
Electric pulse meter inputs: 5 V
DC pulse detection (voltage
supplied by PCB)
Electric pulse meter inputs:
5 V DC pulse detection (voltage
supplied by PCB)
Ext. heat source
External heat source
External indoor ambient sensor
option
External indoor ambient sensor
option
Indoor
Indoor
Max. load
Maximum load
Max. voltage
Maximum voltage
Min. load
Minimum load
Option box
Option box
ON
ON
OFF
OFF
A4P
Extension PCB (control, optional)
DS1 (A4P)
DIP switch
F1U (A4P)
Fuse T 2 A 250 V
F2U (A4P)
Fuse T 2 A 250 V for 3-way valve
R6T
*
External indoor ambient sensor
option
S5P-S6P
#
Electrical meters
X*A (A4P)
Connector
X*M
Terminal strip
*:
Optional
#:
Field supply