8/8
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
A.8
[C-09]
R/W
0: Normally open
1: Normally closed
A.8
[C-0A]
0
A.8
[C-0C]
R/W
0~7
0
A.8
[C-0D]
R/W
0~7
0
A.8
[C-0E]
R/W
0~7
0
A.8
[D-00]
R/W
0~3
0: None
2: BUH only
A.8
[D-01]
R/W
0: No
1: Open tariff
2: Closed tariff
3: Thermostat
A.8
[D-02]
R/W
0~4
0: No
1: Secondary rtrn
2: Disinf. shunt
A.8
[D-03]
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
A.8
[D-04]
R/W
0: No
1: Pwr consmp ctrl
A.8
[D-05]
R/W
0: Forced off
1: As normal
A.8
[D-07]
R/O
0
A.8
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8
[D-0A]
0
A.8
[D-0B]
2
A.8
[D-0C]
R/W
0~49
0
A.8
[D-0D]
R/W
0~49
0
A.8
[D-0E]
R/W
0~49
0
A.8
[E-00]
R/O
0~5
0: LT split
A.8
[E-01]
R/O
0: 8 (*5)
1: 16 (*6)
A.8
[E-02]
R/O
0~1
1: Type 2
A.8
[E-03]
R/O
0~2
1: 1 step
A.8
[E-04]
R/O
0: No (*6)
1: Yes (*5)
A.8
[E-05]
R/W
0: No
1: Yes
A.8
[E-06]
R/O
0: No
1: Yes
A.8
[E-07]
R/O
0~6
1: Type 2
A.8
[E-08]
R/W
0: Disabled (*6)
1: Enabled (*5)
A.8
[E-09]
0
A.8
[E-0A]
0
A.8
[E-0B]
R/O
0~1
1: Yes
A.8
[E-0C]
0
A.8
[E-0D]
0
A.8
[F-00]
R/W
0: Disabled
1: Enabled
A.8
[F-01]
R/W
20
A.8
[F-02]
R/W
3~10°C, step: 1°C
3°C
A.8
[F-03]
R/W
2~5°C, step: 1°C
5°C
A.8
[F-04]
R/W
0: No
1: Yes
A.8
[F-05]
0
A.8
[F-06]
0
A.8
[F-09]
R/W
0: Disabled
1: Enabled
A.8
[F-0A]
0
A.8
[F-0B]
R/W
0: No
1: Yes
A.8
[F-0C]
R/W
1
A.8
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
--
Close shut-off valve during thermo OFF?
--
What is the pump operation mode?
Forced off contact type
Bottom plate heater ON temperature.
Bottom plate heater hysteresis.
Is a bottom plate heater connected?
--
--
Pump operation during flow abnormality.
--
Is a bi-zone kit installed?
--
--
Pump operation allowed outside range.
--
Is the power saving function available on the outdoor unit?
Can the system prepare domestic hot water?
Is a DHW tank installed in the system?
What kind of DHW tank is installed?
Power saving function for outdoor unit.
--
What is the medium electricity price (Do not use)
What is the low electricity price (Do not use)
Which type of unit is installed?
Which type of compressor is installed?
What is the indoor unit software type?
What is the number of backup heater steps?
--
Is an external kWh meter used for power measurement?
Is an external kWh meter used for power measurement?
--
--
What is the high electricity price (Do not use)
Which heaters are permitted if prefer. kWh rate PS is cut?
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
Is a demand PCB connected?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Which type of external sensor is installed?
What is the required alarm output contact type?
--
High electricity price decimal (Do not use)
Medium electricity price decimal (Do not use)
Low electricity price decimal (Do not use)
4P401673-1A - 2017.04
(*5) *04/08*_
(*6) *16*