EKHWS150~3 E300B3Z2

Domestic hot water tank for air to water heat pump system

4PW54951-1

Installation manual

7

General symptoms

Symptom 1: No water flow from hot taps

Symptom 2: Water from hot taps is cold

Symptom 3: Intermittent water discharge

T

ECHNICAL

 

SPECIFICATIONS

Domestic hot water tank specifications

P

OSSIBLE

 

CAUSES

C

ORRECTIVE

 

ACTION

The main water supply is off.

Check that all shut off valves of the 
water circuit are completely open.

P

OSSIBLE

 

CAUSES

C

ORRECTIVE

 

ACTION

The thermal cut-out(s) has/have 
operated

• Check and reset button(s).
• Check if thermistor is correctly 

installed in thermistor socket.

The indoor unit (EKHBH/X) is not 
operating.

Check the indoor unit (EKHBH/X) 
operation. Refer to the manual 
delivered with the indoor unit.
If any faults are suspected, contact 
your local dealer.

P

OSSIBLE

 

CAUSES

C

ORRECTIVE

 

ACTION

Thermal control failure (water will be 
hot).

Switch off power to the indoor unit.
When discharge has stopped, check 
the thermal controls and replace if 
faulty.
Contact your local dealer.

The expansion vessel is broken.

Replace the expansion vessel.

EKHWS150B3V3

EKHWS200B3V3

EKHWS200B3Z2

EKHWS300B3V3

EKHWS300B3Z2

Volume

150 l

200 l

200 l

300 l

300 l

Internal heat exchanger volume

2 l

3 l

3  l

3  l

3  l

Overall dimensions (Ø x H)

580 x 900 mm

580 x 1150 mm

580 x 1150 mm

580 x 1600 mm

580 x 1600 mm

Booster heater, power supply

230 V 50 Hz 1P

230 V 50 Hz 1P

400 V 50 Hz 2P

230 V 50 Hz 1P

400 V 50 Hz 2P

Booster heater, running current

13 A

13 A

7.5 A

13 A

7.5 A

Booster heater, capacity

3 kW

3 kW

3 kW

3 kW

3 kW

Connections

3/4" FBSP

(a)

3/4" FBSP

(a)

3/4" FBSP

(a)

3/4" FBSP

(a)

3/4" FBSP

(a)

Weight (empty)

37 kg

45 kg

45 kg

59 kg

59 kg

Mounting

Wall or floor

Floor

Floor

Floor

Floor

(a) FBSP = Female British Standard Pipe

Summary of Contents for Altherma EKHWS150B3V3

Page 1: ...INSTALLATION MANUAL EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2 Domestic hot water tank for air to water heat pump system ...

Page 2: ...H4 H2 H3 110 H1 105 73 30 5 45 15 100 4 0 0 220 0 0 40 Ø580 300 1 6 9 7 2 3 8 4 5 2 1 1x 1x 2x 4x 1x 1 2 3 5 6 4 3 4 FBSP 3 4 FBSP 1 2 FBSP 3 4 FBSP 3 4 FBSP 62 1x 2 1 ...

Page 3: ...l equipment EKWBSWW150 kit including a wall bracket for a domestic hot water tank of 150 litres EKHWS150B3V3 EKHWS200B3V3 EKHWS200B3Z2 EKHWS300B3V3 EKHWS300B3Z2 Domestic hot water tank for air to water heat pump system Installation manual READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ...

Page 4: ...pplied hot water by the AD domestic hot water tank can exceed 50 C Relevant national or local regulations requiring additional temperature control devices must be complied with The equipment is not intended for use in a potentially explosive atmosphere Only this tank can be used in combination with the solar kit option Domestic hot water quality must be according to EU directive 98 83 EC A drain d...

Page 5: ...ot water tank model EKHWS U 150B3V3 can be floor or wall mounted In case of wall mounting wall mounting kit EKWBSWW150 is required separate ordering Installing the domestic hot water tank 1 Check if all domestic hot water tank accessories see Accessories on page 1 are enclosed 2 When floor mounting place the domestic hot water tank on a level surface When wall mounting only for EKHWS U 150B3V3 mod...

Page 6: ...alve as shown below 9 Make sure to firmly fix the power supply cord onto the 3 way valve body with a field supplied cable tie like in illustration below 10 Perform the wiring in the indoor unit in accordance with the following figure Refer also to the drawing on page 6 11 Connect the water inlet and water outlet 12 Connect the hot and cold water supply tubes 13 Connect the pressure relief valve fi...

Page 7: ... the terminal block X3M and X4M to the earthing screw 7 Connect the booster heater power supply and thermal protection cable field supply to terminal X4M earth 1 2 and X2M 13 14 8 Connect the booster heater power supply cable to the terminal block X3M 9 Fix the cables to the cable tie mountings with cable ties to ensure strain relief 10 Set DIP switch SS2 2 on the PCB to ON 11 When routing out cab...

Page 8: ...C 3 kW L N 400 V AC 3 kW L1 L2 V3 Z2 3 way valve L BRN BLU BLK N Y Before carrying out any maintenance or repair activity always switch off the circuit breaker on the supply panel remove the fuses or open the protection devices of the unit Make sure that before starting any maintenance or repair activity also the power supply to the outdoor unit is switched off Domestic hot water tank pressure rel...

Page 9: ...s are suspected contact your local dealer POSSIBLE CAUSES CORRECTIVE ACTION Thermal control failure water will be hot Switch off power to the indoor unit When discharge has stopped check the thermal controls and replace if faulty Contact your local dealer The expansion vessel is broken Replace the expansion vessel EKHWS150B3V3 EKHWS200B3V3 EKHWS200B3Z2 EKHWS300B3V3 EKHWS300B3Z2 Volume 150 l 200 l ...

Page 10: ...4PW54951 1 Copyright Daikin ...

Reviews: