background image

Timer cancel 

button

In case of
ARC455A, ARC452A, ARC433B, ARC423A, ARC417A

SENSOR

TEMP

ON/OFF

POWERFUL

FAN

MODE

QUIET

ON

CANCEL

TIMER

RESET

OFF

COMFORT

SWING

ON

ON

In case of ARC447A

[Check Method]

With the wireless remote controller supplied with the unit, or 
sold separately, malfunction codes by failure diagnosis can be 
confirmed. (hold the timer cancel button down for 5 seconds.)

1. Hold the timer cancel button down for 5 seconds, with the 

remote controller set toward the indoor unit.

2. The temperature display on the remote controller changes 

to the error code display and a long beep notifies this 
indication change.

Note:

To cancel indication of malfunction code, hold the timer 
cancel button down for 5 seconds.
The code display also cancels itself if the button is not 
pressed for 1 minute.

[Check Method 1]

1. When the timer cancel 

button is held down for 5 
seconds, a “

00

” indication 

flashes on the temperature 
display section.

2. Press the timer cancel 

button repeatedly until a 
continuous beep is 
generated

„

The code indication 
changes in the sequence 
shown below, and notifies 
with a long beep.

[Check Method 2]

1. Press the 3 buttons (TEMP    , TEMP    , 

MODE) simultaneously to enter the 
diagnosis mode.

<In case of ARC433B67, 68, 69, 76>

Note:

1. A short beep and two consecutive beeps indicate non-

corresponding codes.

2. To cancel the code display, hold the timer cancel button 

down for 5 seconds. The code display also cancels itself if 
the button is not pressed for 1 minute.

The figure of the ten's place blinks.

 

Try again from the start when the figure 
does not blink.

Self-Diagnosis by Remote Controller (Residential Air-conditioner)

TIMER CANCEL button

2. Press TEMP    or    button and change the 

figure until you hear the sound of “beep” or 
“pi pi”.

3. Diagnose by the sound.

 

“1 short beep” : The figure of the ten's place 
does not accord with the malfunction code.

 

“2 short beep” : The figure of the ten's place 
accords with the error code but the one's not.

 

“1 long beep” : The both figures of the 
ten's and one's place accord with the 
malfunction code.

4. Press the MODE button.

The figure of the one’s place blinks.

5. Press the TEMP button.

Press TEMP     or     button and change the 
figure until you hear the sound of “long beep”.

6. Diagnose by the sound.

 

“1 short beep” : The figure of the ten's 
place does not accord with the 
malfunction code.

 

“2 short beep” : The figure of the ten's place 
accords with the error code but the one's not.

 

“1 long beep” : The both figures of the ten's 
and one's place accord with the error code.

7. Determine the malfunction code.

The digits indicated when you hear the 
“long beep” sound are error code.

8. Press the MODE button to exit from the 

diagnosis mode.

The display “    ” means the trial operation 
mode.

9. Press the ON/OFF button twice to return 

to the normal mode.

Note:

When the remote controller is left untouched 
for 60 seconds, it returns to the normal mode.

No.

1
2
3
4
5
6
7
8
9

10
11

Code

00
U4
F3
E6
L5
A6
E5
F6
C9
U0
E7

No.

12
13
14
15
16
17
18
19
20
21
22

Code

C7
H8
J3
A3
A1
C4
C5
H9
J6
UA
A5

No.

23
24
25
26
27
28
29
30
31
32
33

Code

H0
E1
P4
L3
L4
H6
H7
U2
UH
EA
AH

Summary of Contents for ARC447A

Page 1: ...ing operations 1 short beep Conduct steps 3 and 4 Continue the operation in step 4 until a buzzer remains ON The continuous buzzer indicates that the malfunction code is confirmed Continuous beep No a...

Page 2: ...button is not pressed for 1 minute The figure of the ten s place blinks Try again from the start when the figure does not blink Self Diagnosis by Remote Controller Residential Air conditioner TIMER CA...

Page 3: ...Malfunction of thermistor Refrigerant circuit Malfunction of thermistor Refrigerant circuit Malfunction of high pressure sensor Malfunction of low pressure sensor Malfunction of oil pressure sensor or...

Page 4: ...ollers Malfunction of transmission other system Improper combination of indoor and outdoor units Malfunction of setting of centralized control equipment address Malfunction of transmission between ind...

Page 5: ...ure thermistor in remote controller abnormality Defective room temperature thermistor in remote controller Defective remote controller PCB External factor Noise etc k k k k k Malfunction code Malfunct...

Page 6: ...nsor in mistake for low pressure sensor Defective low pressure sensor Defective outdoor unit PCB k k k k Malfunction code Malfunction Contents Supposed causes Objects RA SkyAir VRV Package Heat reclai...

Page 7: ...k k Malfunction code Malfunction Contents Supposed causes Objects RA SkyAir VRV Package Heat reclaim ventilator Chiller Fan Coil System U7 Malfunction of transmission between outdoor units or outdoor...

Page 8: ...n of heat exchanger thermistor Defective connector contact Defective heat exchanger thermistor k 86 System No 1 Malfunction of discharge pipe thermistor Defective connecting connector Defective discha...

Reviews: