Si12-714
Specifications
Specifications
23
50Hz 220-230-240V / 60Hz 220-230V
Note:
1. The data are based on the conditions shown in the table below.
Model
3MKD75DVM
4MKD75DVM
Cooling Capacity
kW
—
—
Power Consumption
W
—
—
Running Current
A
—
—
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC45ZXD
2YC45ZXD
Motor Output
W
1,380
1,380
Refrigerant Oil
Model
SUNISO 4GSD.I.
SUNISO 4GSD.I.
Charge
L
0.75
0.75
Refrigerant
Type
R-22
R-22
Charge
kg
2.3
2.3
Air Flow Rates
m³/min
H
51
51
L
45
45
cfm
H
1,472
1,472
L
1,299
1,299
Fan
Type
Propeller
Propeller
Motor Output
W
53
53
Running Current
A
H: 0.33 / L: 0.25
H: 0.33 / L: 0.25
Power Consumption
W
H: 68 / L: 46
H: 68 / L: 46
Starting Current
A
9.4
9.2
Dimensions (H×W×D)
mm
735×936×300
735×936×300
Packaged Dimensions (H×W×D)
mm
784×960×357
784×960×357
Weight
kg
58
58
Gross Weight
kg
62
62
Operation Sound
dBA
48
48
Piping Connection
Liquid
mm
φ
6.4×1,
φ
9.5×2
φ
6.4×2,
φ
9.5×2
Gas
mm
φ
12.7×1,
φ
15.9×2
φ
12.7×2,
φ
15.9×2
Drain
mm
φ
16.0
φ
16.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
No. of Wiring Connection
3 for Power Supply, 4 for Interunit Wiring
3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m
60 (for Total of Each Room)
60 (for Total of Each Room)
m
25 (for One Room)
25 (for One Room)
Amount of Additional Charge
g/m
Chargeless
Chargeless
Max. Installation Height Difference
m
15 (between Indoor Unit and Outdoor Unit)
15 (between Indoor Unit and Outdoor Unit)
m
15 (between Indoor Units)
15 (between Indoor Units)
Drawing No.
3D050083#1A
3D050084#1B
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
7.5m