Instruction
SiENBE18-621
156
System Configuration
"
Outdoor Unit
"
Indoor Unit
"
Outdoor Unit
Appearance of the outdoor unit may differ from some models.
1. Air filter
2. Titanium Apatite Photocatalytic Air-Purifying Filter:
•
These filters are attached to the inside of the air filters.
3. Air inlet
4. Front panel
5. Panel tab
6. Room temperature sensor:
•
It senses the air temperature around the unit.
7. INTELLIGENT EYE sensor:
•
It detects the movements of people and automatically
switches between normal operation and energy saving
operation.
8. Display
9. Air outlet
10. Flaps (horizontal blades)
11. Louvers (vertical blades):
•
The louvers are inside of the air outlet.
12. Indoor Unit ON/OFF switch:
•
Push this switch once to start operation. Push once
again to stop it.
•
The operation mode refers to the following table.
•
This switch is useful when the remote control is
missing.
13. Operation lamp (green)
14. TIMER lamp (yellow)
15. INTELLIGENT EYE lamp (green)
16. Signal receiver:
•
It receives signals from the remote control.
•
When the unit receives a signal, you will hear a short
beep.
•
Operation start ..............beep-beep
•
Settings changed...........beep
•
Operation stop ..............beeeeep
17. Air inlet: (Back and side)
18. Air outlet
19. Refrigerant piping and inter-unit cable
20. Drain hose
21. Earth terminal:
•
It is inside of this cover.
22. Outside air temperature sensor:
•
It senses the ambient temperature around the unit.
19
22
20
21
1
8
17
Mode
Temperature
setting
Air flow
rate
F(C)TKS
COOL
22°C
AUTO
F(C)TXS
AUTO
25°C
AUTO
Summary of Contents for BPMKS967B2B
Page 1: ...SiENBE18 621 E Series Service Manual Applied Models Super Multi Plus Heat Pump...
Page 12: ...SiENBE18 621 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 19: ...List of Functions SiENBE18 621 8 List of Functions...
Page 33: ...Specifications SiENBE18 621 22 Specifications...
Page 69: ...Refrigerant Flow for Each Operation Mode SiENBE18 621 58 Refrigerant Circuit...
Page 121: ...Indoor Unit SkyAir Models SiENBE18 621 110 Function...
Page 169: ...Instruction SiENBE18 621 158 System Configuration FTXS 20 25 35C Indoor Unit...
Page 371: ...Method of Replacing The Inverter s Power Transistors Modules SiENBE18 621 360 Troubleshooting...
Page 393: ...SiENBE18 621 vi Index...