Instruction
SiENBE18-621
198
System Configuration
“INTELLIGENT EYE” is useful for Energy Saving
Notes on “INTELLIGENT EYE”
CAUTION
"
Energy saving operation
•
Change the temperature –2°C in heating / +2°C in cooling / +2°C in dry mode from set temperature.
•
Decrease the air flow rate slightly in fan operation. (In FAN mode only)
•
Application range is as follows.
•
Sensor may not detect moving objects further than 7m away. (Check the application range)
•
Sensor detection sensitivity changes according to indoor unit location, the speed of passersby, temperature range, etc.
•
The sensor also mistakenly detects pets, sunlight, fluttering curtains and light reflected off of mirrors as passersby.
•
INTELLIGENT EYE operation will not go on during powerful operation.
•
Night set mode will not go on while you use INTELLIGENT EYE operation.
•
Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor’s detection area.
This sensor can detect objects it shouldn’t as well as not detect objects it should.
•
Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.
90°
55°
7m
55°
7m
Vertic
a
l
a
ngle 90°
(
S
ide View)
Horizont
a
l
a
ngle 110°
(Top View)
Summary of Contents for BPMKS967B2B
Page 1: ...SiENBE18 621 E Series Service Manual Applied Models Super Multi Plus Heat Pump...
Page 12: ...SiENBE18 621 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 19: ...List of Functions SiENBE18 621 8 List of Functions...
Page 33: ...Specifications SiENBE18 621 22 Specifications...
Page 69: ...Refrigerant Flow for Each Operation Mode SiENBE18 621 58 Refrigerant Circuit...
Page 121: ...Indoor Unit SkyAir Models SiENBE18 621 110 Function...
Page 169: ...Instruction SiENBE18 621 158 System Configuration FTXS 20 25 35C Indoor Unit...
Page 371: ...Method of Replacing The Inverter s Power Transistors Modules SiENBE18 621 360 Troubleshooting...
Page 393: ...SiENBE18 621 vi Index...