background image

1

English

Contents

Safety considerations   ...................................  1
Before installation   .........................................  1

Accessories ...................................................................   1
Note to the installer .......................................................   1

Remote controller installation   ......................  2

Installing the wireless remote controller ........................   2
Determination of address and  
MAIN/SUB remote controller .........................................   2
Setting procedure ..........................................................   2
Installation of the transmitter board ...............................   3
Installation of the decoration panel ...............................   3
Installation of the receiver in case of BRC082A41W ....   4
Installation of the receiver in case of BRC082A42W/S ....   4

Field setting   ....................................................  5

READ THIS MANUAL ATTENTIVELY BEFORE 
STARTING UP THE UNIT. DO NOT THROW IT 
AWAY. KEEP IT IN YOUR FILES FOR FUTURE 
REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT 
OF EQUIPMENT OR ACCESSORIES COULD 
RESULT IN ELECTRIC SHOCK, SHORTCIRCUIT, 
LEAKS, FIRE OR OTHER DAMAGE TO 
THE EQUIPMENT. BE SURE ONLY TO USE 
ACCESSORIES MADE BY DAIKIN WHICH ARE 
SPECIFICALLY DESIGNED FOR USE WITH THE 
EQUIPMENT AND HAVE THEM INSTALLED BY A 
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES 
OR USE, ALWAYS CONTACT YOUR DAIKIN 
DEALER FOR ADVICE AND INFORMATION.

The English text is the original instruction. Other languages 
are translations of the original instructions.

Safety considerations

Please read this “Safety considerations” carefully before 
installing air conditioning equipment and be sure to install it 
correctly. After completing the installation, make sure at start 
up operation that the unit operates properly. Please instruct 
the customer how to operate the unit and how to perform 
maintenance.

Meaning of caution symbols

Failure to observe these instructions properly may 
result in property damage or personal injury.

Information classified as 

NOTE contains instructions to 

ensure proper use of the equipment.

 

„

Refer also to the installation manual supplied 
with the indoor unit and the installation manual 
supplied with the decoration panel.

 

„

There is only 1 possible installation position of 
this kit into the decoration panel. It is therefore 
recommended that installation orientation of the 

decoration panel is confirmed prior to installation 

of this kit.

• 

Ensure that nothing interrupts operation of the 
wireless remote controller.

• 

Ensure that the signal from the remote 
controller can easily be transmitted.

• 

Ensure that the operation display lamp and 
other indicator lamps can easily be seen.

• 

Ensure that there is neither a source of light nor 

a fluorescent lamp near the receiver.

• 

Ensure that the receiver is not exposed to direct 
sunlight.

Before installation

Accessories

See figure 1. Check if the following accessories are included 

with your kit.

Receiver
Transmitter board
Wireless remote controller
Remote controller holder
Alkaline battery of type AAA.LR03
Unit number label
Screw for installing remote controller holder
Installation manual
Operation manual

10 Clamp
11 Plastic spacer
12 Plastic band
13 Sealing

Note to the installer

Be sure to instruct the customer how to properly operate the 
system showing him/her the supplied operation manual.

English

01_EN_3P444567-1.indd   1

7/5/2016   11:05:26 AM

Summary of Contents for BRC082A41W

Page 1: ...añol WIRELESS REMOTE CONTROLLER KIT INSTALLATION MANUAL Installation manual Manuel dinstallation Manual de instalación MODELS BRC082A41W BRC082A42W BRC082A42S Manuel dinstallation 00_CV_3P444567 1 indd 1 5 11 2016 13 44 03 ...

Page 2: ...BRC082A42W 1 1 3 4 1 1 BRC082A42S 1 1 3 4 1 1 Figure 1 X24A X1A X2A 1 7 2 3 6 2 7 5 3 4 2 Figure 2 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING A B C 3 2 4 1 5 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING B D C A 3 2 4 5 1 6 Figure 3 Figure 4 00_CV_3P444567 1_H2 indd 1 6 29 2016 2 25 08 PM ...

Page 3: ...ow to operate the unit and how to perform maintenance Meaning of caution symbols Failure to observe these instructions properly may result in property damage or personal injury Information classified as NOTE contains instructions to ensure proper use of the equipment Refer also to the installation manual supplied with the indoor unit and the installation manual supplied with the decoration panel T...

Page 4: ...eceiver and the wireless remote controller If using both a wired remote controller and a wireless remote controller with one indoor unit change the MAIN SUB switch of the transmitter board Setting procedure Setting the transmitter board Set the wireless address switch SS2 on the transmitter board according to the table below Unit No 1 2 3 Wireless address switch SS2 1 2 3 1 2 3 1 2 3 When using bo...

Page 5: ...he indications on the wireless remote controller are turned off a discrepancy such as described above no longer occurs Affix the unit number label Affix corresponding unit number labels onto both air outlet of the decoration panel and onto back of the wireless remote controller NOTE Set the Unit No of the receiver and the wireless remote controller to be equal If the settings differ the signal fro...

Page 6: ...e decoration panel Then attach the receiver to the decoration panel Lead the wire harness to the electrical wiring box on the indoor unit and connect it to X1A connector on the transmitter board Remove the screw and input the plastic band Then screw it back The wire harness goes through the plastic band Clamp the wire harness from the receiver to other cables with the clamp Installation of the rec...

Page 7: ... setting If optional accessories are mounted on the indoor unit the indoor unit setting may have to be changed Refer to the instruction manual option handbook for each optional accessory See figure 4 A Mode No B Field Set mode C First code No D Second code No Procedure 1 When in normal mode hold down the button for at least 4 seconds to enter the Field Set mode 2 Select the desired Mode No with th...

Page 8: ...nged in function of ceiling height H 8 7 8ft 2 7m 8 7 8 H 9 13 16ft 2 7 H 3 0m 9 13 16 H 11 1 2ft 3 0 H 3 5m 1 Selection of air flow direction This setting is to be changed when blocking pad optional kit is used 4 way flow 3 way flow 2 way flow 4 Airflow direction range setting This setting is to be changed when range of swing flap movement needs to be changed Upper Medium Lower NOTE Factory setti...

Page 9: ...Two dimensional bar code is a manufacturing code 3P444567 1 M15B280 1607 HT 00_CV_3P444567 1 indd 2 5 11 2016 13 44 03 ...