background image

5

English

4  Pass the wire harness through the hole and insert the 

cover into its position and screw it.

Clamp for 
positioning

Clamp the wire harness 
to the hook next to the 
positioning clamp.

Stick the sealing 
(supplied with receiver) 
around the wire 
harness in the place 
where the wire harness 
enter the unit.

Clamp the wire 
harness to other 
cables.

1  Remove the screw.
2  Insert the plastic band 

(supplied with receiver). 
The wire harness should 
go through the clamp.

3  Put the screw back.

Field setting

If optional accessories are mounted on the indoor unit, the 
indoor unit setting may have to be changed. Refer to the 
instruction manual (option handbook) for each optional 
accessory.

(See figure 4)

A  Mode No.
B  Field Set mode
C  First code No.
D  Second code No.

Procedure
1  When in normal mode, hold down the 

 button for 

at least 4 seconds to enter the Field Set mode.

2  Select the desired Mode No. with the 

 button.

3  Press the   button and select the First code No.
4  Press the 

 button and select the Second code No.

5  Press the 

 button to confirm the settings.

6  Press the 

 button to quit the Field Set mode and 

to return to normal display again.

English

01_EN_3P444567-1.indd   5

7/5/2016   11:05:30 AM

Summary of Contents for BRC082A41W

Page 1: ...añol WIRELESS REMOTE CONTROLLER KIT INSTALLATION MANUAL Installation manual Manuel dinstallation Manual de instalación MODELS BRC082A41W BRC082A42W BRC082A42S Manuel dinstallation 00_CV_3P444567 1 indd 1 5 11 2016 13 44 03 ...

Page 2: ...BRC082A42W 1 1 3 4 1 1 BRC082A42S 1 1 3 4 1 1 Figure 1 X24A X1A X2A 1 7 2 3 6 2 7 5 3 4 2 Figure 2 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING A B C 3 2 4 1 5 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING B D C A 3 2 4 5 1 6 Figure 3 Figure 4 00_CV_3P444567 1_H2 indd 1 6 29 2016 2 25 08 PM ...

Page 3: ...ow to operate the unit and how to perform maintenance Meaning of caution symbols Failure to observe these instructions properly may result in property damage or personal injury Information classified as NOTE contains instructions to ensure proper use of the equipment Refer also to the installation manual supplied with the indoor unit and the installation manual supplied with the decoration panel T...

Page 4: ...eceiver and the wireless remote controller If using both a wired remote controller and a wireless remote controller with one indoor unit change the MAIN SUB switch of the transmitter board Setting procedure Setting the transmitter board Set the wireless address switch SS2 on the transmitter board according to the table below Unit No 1 2 3 Wireless address switch SS2 1 2 3 1 2 3 1 2 3 When using bo...

Page 5: ...he indications on the wireless remote controller are turned off a discrepancy such as described above no longer occurs Affix the unit number label Affix corresponding unit number labels onto both air outlet of the decoration panel and onto back of the wireless remote controller NOTE Set the Unit No of the receiver and the wireless remote controller to be equal If the settings differ the signal fro...

Page 6: ...e decoration panel Then attach the receiver to the decoration panel Lead the wire harness to the electrical wiring box on the indoor unit and connect it to X1A connector on the transmitter board Remove the screw and input the plastic band Then screw it back The wire harness goes through the plastic band Clamp the wire harness from the receiver to other cables with the clamp Installation of the rec...

Page 7: ... setting If optional accessories are mounted on the indoor unit the indoor unit setting may have to be changed Refer to the instruction manual option handbook for each optional accessory See figure 4 A Mode No B Field Set mode C First code No D Second code No Procedure 1 When in normal mode hold down the button for at least 4 seconds to enter the Field Set mode 2 Select the desired Mode No with th...

Page 8: ...nged in function of ceiling height H 8 7 8ft 2 7m 8 7 8 H 9 13 16ft 2 7 H 3 0m 9 13 16 H 11 1 2ft 3 0 H 3 5m 1 Selection of air flow direction This setting is to be changed when blocking pad optional kit is used 4 way flow 3 way flow 2 way flow 4 Airflow direction range setting This setting is to be changed when range of swing flap movement needs to be changed Upper Medium Lower NOTE Factory setti...

Page 9: ...Two dimensional bar code is a manufacturing code 3P444567 1 M15B280 1607 HT 00_CV_3P444567 1 indd 2 5 11 2016 13 44 03 ...