ED72-975

Operation Manual

BRC1E61

15

3P243520-1

English 

11

Operation mode
1. 

Used to display the present operation  

Ɣ

mode Cool, Heat, V

ent, Fan, Dry or 

Auto 

mode.

Automatic operation mode
2. 

Used to display the present automatic  

Ɣ

operation mode (Cool or Heat).

Fan speed
3. 

Used to display the fan speed that is set for  

Ɣ

the air conditioner

.

The fan speed will not be displayed if the  

Ɣ

air conditioner does not have fan speed 

control function.

Set temperature display
4. 

Used to display the temperature set for the  

Ɣ

air conditioner

.

Defrost/Hot start “
5. 

” 

(See page 16.)

If V

entilating operation “ 

 ” is displayed:

Displayed when a total heat exchanger  

Ɣ

unit, such as the V

entiair

, is connected.

For details, refer to the Operation Manual 

of the V

entiair

.

Message
6. 

The following messages are displayed.

“This function not available.”

Displayed for a few seconds when an  

Ɣ

operation button is pressed if the indoor 

unit is not provided with the corresponding 

function.

If a number of indoor units are in operation,  

Ɣ

the message will appear only if none of the 

indoor units is provided with the 

corresponding function, i.e., the message 

will not appear if at least one of the indoor 

units is provided with the corresponding 

function.

“Error: Press Menu Button.”

“W

arning: Press Menu Button.”

Displayed if the error or warning is detected  

Ɣ

(see page 53)

.

“Quick Cool/Heat” 

(SkyAir only)

Displayed if the quick cooling/heating  

Ɣ

function is turned ON 

(see page 31).

“Clean the fi

 lter

.”

“Clean the element.”

“Clean the fi

 lter and element.”

Displayed when the time to clean the fi

 lter 

 

Ɣ

or element has come 

(see page 51).

V

entilation / Purifying

7. 

Displayed when a total heat exchanger  

Ɣ

unit, such as the V

entiair

, is connected.

V

entilation mode icon.“

 

Ɣ

 

 

These icons indicate the current ventilation 

mode (HR

V only) (AUT

OMA

TIC, HEA

T

 

EXCHANGE, BYP

ASS).

AIR Purifying ICON “ 

 

Ɣ

 ”

This icon indicates that the air cleaning unit 

(option) is operational.

8. display 

(See page 23.)

Displayed when the key lock is set. 

Ɣ

9. display 

(See page 34.)

Displayed if the schedule timer or OFF  

Ɣ

reminder timer is enabled.

Under Centralized control “

10. 

Displayed if the system is under the  

Ɣ

management of central control equipment 

(optional accessories) and the operation of 

the system through the remote controller is 

prohibited.

Changeover under control “

1

1. 

” 

(VR

V

 only)

Displayed on the remote controller if the  

Ɣ

remote controller has no cooling/heating 

selection eligibility mode

 (see page 21)

.

01_EN_3P243520-1.indd   11

2/6/2009   5:49:58 PM

10 

English

Liquid Crystal Display

T

wo types of liquid crystal display (LCD) are available. 

The standard display is by 

 

Ɣ

default set.

T

o

 go to the detailed display

, select the detailed display in the main menu. 

 

Ɣ

(See page 46.)

The displayed contents of the screen vary with the operation mode of the equipment  

Ɣ

interlocked. (The following display will appear when the air conditioner is in automatic 

heating operation.)

  Standard display  

Set temperature 

20

°C 

Auto 

Heat

This function not available

<Standard display example> 

7. 

V

e

ntilation

3. 

Fan speed

1. 

Operation mode

12.Home Leave

8. 

(     ) display

4. 

Set temperature 

 display

5. 

Defrost/Hot start

6. 

Message

1

1

. Changeover under control

10.Under centralized 

 control

9. 

(   ) display

2. 

Automatic 

 operation 

mode

  Detailed display  

The airfl

 ow direction, clock, and detailed selection items appear 

 

„

on the detailed display screen in addition to the items appearing 

on the standard display

.

Set temp 

A

12

:05

Room

20

°C

20

°C

Auto 

Return Setting 

Heat

15. 

Detailed selection

 (with 

room 

 temperature 

settings)

13. 

Airflow direction

 

(Displayed only when 

 

the air conditioner is in 

 operation.)

14. 

Clock (24 hours 

 

real time clock)

<Detailed display example 1> 

Set temp 

A

--

:-- 

20

°C 

Auto 

Return Setting 

Heat

<Detailed display example 2> 

Airflow direction

display 

(with no airflow direction 

settings)

3. 

Fan speed display

 

(with no fan speed 

 control 

function)

Detailed selection  

(with no detailed items 

selected)

Clock display 

(with no clock settings)

16. 

(    ) display

Names and Functions

01_EN_3P243520-1.indd   10

2/6/2009   5:49:57 PM

Summary of Contents for BRC1E61

Page 1: ...ED72 975 Navigation Remote Controller Wired Remote Controller BRC1E61...

Page 2: ...Direct Buttons 17 6 4 Quick Reference of Main Menu Items 22 6 5 Menu Manipulation 23 6 6 Maintenance 35 6 7 Useful Information 36 7 Installation Manual 38 7 1 Safety Precautions 38 7 2 Accessories 39...

Page 3: ...Multilingual Display Available for selection of 10 languages to display arbitrarily Other Features Wide variety of functions to meet customer needs such as schedule setting and contact address displa...

Page 4: ...imple and Functional Design 1 3 Simple Operation Compared to the conventional structure of button allocation for each function the number of buttons has been decreased from 15 to 9 Can intuitively han...

Page 5: ...system Available for simple operation with arrow keys and menu driven system Available for simple operation with arrow keys and menu driven system Select the item you wish to set with direction keys a...

Page 6: ...1 5 Available for simple operation with arrow keys and menu driven system Guide on display The item you wish to set can be changed with up or down button The display gives an explanation of each setti...

Page 7: ...r display in 10 different languages Always available for switching display by selecting from main menu 10 languages English German French Spanish Italian Portuguese Greek Dutch Russian and Turkish Ope...

Page 8: ...ED72 975 Features BRC1E61 7 1 5 Other Functions...

Page 9: ...ot be set with the sub remote controller Restriction of operation from the sub remote controller When the On Off button is pressed in the sub remote controller during Home Leave operation in the main...

Page 10: ...te controller DCS303A51 Wiring adaptor for electrical appendices KRP2A5 6 3 Quick Cooling Heating restriction for SkyAir only Under the following conditions Quick Cooling Heating operation stops to re...

Page 11: ...975 10 BRC1E61 4 Dimensions 5 Applicable Models 5 1 Applicable Models 3D064037 Applicable Indoor unit VRV All models that can be connected BRC1C62 or BRC1D61 SkyAir All models that can be connected BR...

Page 12: ...mote controller by yourself Improper installation may result in electric shocks or re Consult your Daikin dealer Do not use ammable materials e g hairspray or insecticide near the product Do not clean...

Page 13: ...nsult the dealer if the air conditioner submerges owing to a natural disaster such as a ood or typhoon Do not operate the air conditioner in that case or otherwise a malfunction electric shock or re m...

Page 14: ...Safety Precautions 01_EN_3P243520 1 indd 6 2 6 2009 5 49 57 PM English 5 CAUTION After prolonged use check the unit stand and its mounts for damage If left in a damaged condition the unit may fall an...

Page 15: ...nd side Each screen is scrolled in the left hand direction Home leave settings are enabled with this button kept pressed for at least four seconds See page 19 On Off button 8 Press this button and sys...

Page 16: ...lay See page 23 Displayed when the key lock is set 9 display See page 34 Displayed if the schedule timer or OFF reminder timer is enabled Under Centralized control 10 Displayed if the system is under...

Page 17: ...on and swing are set see page 28 This item is not displayed if the system is not provided with a function to set air ow directions Clock 24 hours real time clock 14 Displayed if the clock is set see p...

Page 18: ...ayed Return Setting MainMenu Set temp mode changeover Airflow Direction Quick Cool Heat On Off Ventilation Timer setting Service Contact Model info 1 2 Return Setting Timer setting Schedule timer Off...

Page 19: ...h 6 The Operation lamp will be turned OFF and the system will stop operating when On Off button is pressed again While the system is in heating operation the system will be in fan operation for approx...

Page 20: ...main menu see page 28 The air ow direction of the system cannot be changed unless the system is provided with a function to allow air ow direction changes 4 The Operation lamp will be turned OFF and...

Page 21: ...ime Selection Settings 2 Set temperature 28 C Cool Return Setting Set temperature 28 C Cool Return Setting Press Operation Mode Selector button of the remote controller for which the selection eligibi...

Page 22: ...28 C Cool Return Setting Press the remote controller that has the cooling heating selection eligibility or the remote controller without the display Changeover under control several times until the d...

Page 23: ...mer Off reminder timer Home leave 01_EN_3P243520 1 indd 25 2 6 2009 5 50 03 PM 24 English The main menu has the following items Setting and display items Description Reference page Set temp mode chang...

Page 24: ...s highlighted and ready to be changed The set temperature will increase by 1 C when the button is pressed and decrease by 1 C when the button is pressed Note The difference between the maximum and min...

Page 25: ...rn to the basic screen 01_EN_3P243520 1 indd 29 2 6 2009 5 50 04 PM 28 English Air ow Direction Setting Manipulating Air ow Direction Setting Operation Method 1 Return Setting MainMenu Set temp mode c...

Page 26: ...n the main menu screen Press Menu Enter button to return to the basic screen Quick Cooling Heating will no longer appear on the basic screen Quick Cooling Heating is now off 01_EN_3P243520 1 indd 31 2...

Page 27: ...comfortable temperature Fan speed display goes off and fan speed can no longer be switched Cannot be set when in fan and dry modes Quick Cooling Heating mode will run for a maximum of 30 minutes befo...

Page 28: ...temperature 28 C Cool Return Setting Selecting the desired ventilation mode and pressing Menu Enter button enters the settings and takes you back to the basic screen Pressing the Cancel button takes y...

Page 29: ...be changed Press buttons to change the set temperature The set temperature will increase by 1 C when the button is pressed and decrease by 1 C when the button is pressed Pressing Menu Enter button ent...

Page 30: ...nter button enters the schedule timer settings and takes you back to the basic screen 01_EN_3P243520 1 indd 39 2 6 2009 5 50 08 PM 38 English 5 Return Setting Monday Schedule timer Time Operation 06 0...

Page 31: ...09 PM 40 English Holiday setting The schedule timer will be disabled for days that have been set as holiday Operation Method 1 Return Setting Schedule timer Enable Disable setting Condition setting Ho...

Page 32: ...ings Operation Method 1 Return Setting Schedule timer Disable Off reminder Timer Disable Timer setting Bring up the timer settings screen See page 34 Press buttons to select the Off reminder timer on...

Page 33: ...5 2 6 2009 5 50 10 PM 44 English Service Contact Model Information Display method for service contact and model information Operation Method 1 Return Setting MainMenu Set temp mode changeover Airflow...

Page 34: ...ed by factors such as the location of the unit if it is in direct sunlight for e g and unit operation during defrosting After setting press Menu Enter button to con rm settings and return to the basic...

Page 35: ...December 31 2099 Note 01_EN_3P243520 1 indd 49 2 6 2009 5 50 12 PM 48 English Setting Status List Manipulating the setting status list Operation Method 1 Return Setting MainMenu Convenient functions S...

Page 36: ...button The display shown in 1 will disappear from the basic screen when the lter sign is reset 01_EN_3P243520 1 indd 51 2 6 2009 5 50 13 PM 50 English 7 Return Setting Is it settled by setting Clock...

Page 37: ...ify your Daikin dealer of the Error code and Model name 01_EN_3P243520 1 indd 53 2 6 2009 5 50 14 PM 52 English Caution Do not wash the remote controller Doing so may cause electric leakage and result...

Page 38: ...ems Model name Date of installation Failure conditions As precise as possible Your address name and telephone number Relocation The relocation of the remote controller requires special technology Cons...

Page 39: ...eakage electric shocks or re Be sure to use only the speci ed accessories and parts for installation work Failure to use the speci ed parts may result in the unit falling water leaakage electric shock...

Page 40: ...mote controller with water as this may result in electric shocks or re Install the indoor and outdoor units power cord and connecting wires at least 1 meter away from televisions or radios to prevent...

Page 41: ...EMC Electromagnetic Compatibility Australian regulation NOTE 01_EN_3P243521 1 indd 6 2 3 2009 1 19 17 PM English 5 Determine the direction of controller wiring outlet back 3 4 outlet left outlet upper...

Page 42: ...y using attached small screws 2 pcs Small screws M4 16 Switch box field supply Use optional accessory KJB211A Switch box for two units with no cover 84 46 Installation pitch 01_EN_3P243521 1 indd 8 2...

Page 43: ...t temperature The next items on the lower side will be highlighted The highlighted items will be scrolled continuously when the button is kept pressed Used to change the item selected Right button 6 U...

Page 44: ...or longer the Operation mode selector button of sub remote controller side Connection under check Please wait for a moment Sub remote contrl Basic screen 2 5 Set temperature 28 C Fan Return Press the...

Page 45: ...screen 6 6 7 6 Return Setting Is it settled by setting Field setting list Yes No Press Menu Enter button Setting con rmation 01_EN_3P243521 1 indd 14 2 3 2009 1 19 21 PM English 13 Field setting meth...

Page 46: ...light lit Field setting menu screen 5 7 Return Setting Field setting Test operation ON OFF Register Service Contract Field setting list Group No setting Indoor unit Airnet No set Outdoor unit Airnet N...

Page 47: ...hin about 10 seconds The test operation starts Check operation condition for 3 minutes Note In the case of above men tioned procedures 7 5 and 7 6 in reverse order test operation can start as well Pre...

Page 48: ...nter button Field setting menu screen 01_EN_3P243521 1 indd 20 2 3 2009 1 19 25 PM English 19 Remote controller display Description No display Power outage power voltage error or open phase Wrong wiri...

Page 49: ...asic screen Main menu screen 1 11 Return Setting MainMenu Convenient functions Setting status list Clock setting Language changeover 2 2 Press Menu Enter button 2 11 3 11 Return Setting Clock setting...

Page 50: ...ED72 975 Printed in Japan 06 2009 K FS Specifications designs and other content appearing in this brochure are current as of April 2009 but subject to change without notice...

Reviews: