17
Ventilation Operation
When Air Conditioner Interlocked with Heat Reclaim Ventilator
Preparation
•
For equipment protection purposes, turn on the pow
er to the air conditioner at least 6 hours
before starting the operation.
1
Vent
•
Press Mode Selector button several times until
Vent mode is selected.
* Vent mode is for single operation of Heat Reclaim
Ventilator for the season when cooling/heating is
unnecessary.
2
•
The Ventilation mode can be changed from the Main Menu.
(Refer to page 33).
* Ventilation mode: Auto, Energy Reclaim Ventilation and Bypass
3
•
The Ventilation rate can be changed from the Main Menu.
(Refer to page 32).
* Ventilation rate: Low or High
4
•
Press ON/OFF button.
The Operation lamp (green) will be lit and the Heat
Reclaim Ventilator will start operating.
5
•
When ON/OFF button is pressed again, the Heat
Reclaim Ventilator will stop operating and the
Operation lamp will be turned off.
Operation