background image

 

14

10. MAINTENANCE  

(FOR SERVICE PERSONNEL)

Refer to the operation manual attached to the 
indoor unit.

11. NOT MALFUNCTION OF THE 

AIR CONDITIONER

Refer to the operation manual attached to the 
indoor unit.

And the following symptoms do not 

indicate air conditioner malfunction

 

I

.   THE AIR CONDITIONER DOES NOT 

OPERATE

• 

The receiving tone of the indoor unit 

makes a triple beeping sound (normally, 

“beep-beep”).

 

This is because the air conditioner is under 
centralized control.

• 

After the HEATING OPERATION is started, 

the DEFROST OPERATION LAMP located 

on the indoor unit lights up.

 

The indoor fan runs to discharge a gentle 
wind automatically until the temperature 
inside the air conditioner reaches a certain 
level. At this time, the DEFROST 
OPERATION LAMP on the light receiving 
unit indicator lights. Leave it as it stands and 
wait for a while.

• 

The system does not restart immediately 

after the ON/OFF button is pressed. 

If the OPERATION lamp lights, the system is 
in normal condition. It does not restart 
immediately because a safety device 
operates to prevent overload of the system. 
After 3 minutes, the system will turn on again 
automatically.

• 

The system does not restart immediately 

when TEMPERATURE SETTING button  

is returned to the former position after 

pushing the button. 

It does not restart immediately because a 
safety device operates to prevent overload of 
the system.  
After 3 minutes, the system will turn on again 
automatically.

• 

If the defrost lamp on the indoor unit’s 

display is lit when heating is started. 

This indication is to warn against cold air 
being blown from the unit.  
There is nothing wrong with the equipment.

• 

The outdoor unit stops. 

Because the room temperature reaches to 
the set temperature. The indoor unit goes 
into fan operation.

 

II

.   COOLING AND HEATING OPERATIONS 

CAN NOT BE SWITCHED

• 

The receiving tone of the indoor unit 

makes a long beeping sound.

 

An unavailable mode was set for the indoor 
unit under operation changeover control.

 

III

.   THERE IS NO DISPLAY OR ALL PARTS 

ARE DISPLAYED

• 

When a button on the remote controller 

is pressed.

 

The batteries have run out.

 

IV

.   THE UNIT STOPS ONCE IN A WHILE

• 

The remote controller indicates “ ”  

and “ ”, the unit stops. Within several 

minutes the unit restarts.

 

Due to electrical noise other than that from 
the air conditioner, the communication 
between the units is cut off and the unit stops. 
When the noise is gone, the unit automatically 
restarts.

 

V

.   AIRFLOW RATE CANNOT BE OBTAINED 

AS SET

• 

Even if the airflow rate adjusting button is 

pressed, the airflow rate does not change.

 

When the room temperature reaches the 
indoor unit set temperature, the outdoor unit 

stops and the airflow rate of indoor unit 

drops to the minimum.  
This is to avoid the cold air from getting in 
contact with the people in the room.

 

VI

.   AIR DISCHARGE DIRECTION IS NOT  

AS SET

• 

The remote controller indication and the  

air discharge direction is not the same.  

Air discharge direction swing is impossible.

 

Because it is controlled by microcomputer. 
Refer to “

AIRFLOW DIRECTION ADJUST

” 

on page 9, 10.

 

VII

.   ONLY A PART OF INDICATION SHOWS

• 

Even if the unit is operated, only the 

operation indication shows, or even if the 

indication shows, soon after, the indication 

other than that for operation disappears.

 

The corresponding indoor unit is that for 
multi-system and the remote controller is 
set to the multi-system.

Summary of Contents for BRC7M530W

Page 1: ...S BRC7M530W BRC7M531W Thank you for purchasing this product Carefully read this manual to ensure proper operation and installation After reading the manual file it away for future reference Furthermor...

Page 2: ...1 13 2 6 1 3 7 8 12 10 9 11 4 5 18 14 19 17 20 15 16 Fig 1 1 Fig 1 2 Fig 1 3 27 28 COOL HEAT CHANGEOVER REMOTE CONTROL SWITCH Fig 2 24 21 22 25 26 23...

Page 3: ...e printed beneath the symbol This chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Do not try to dismantle the sy...

Page 4: ...on farms or for commercial use by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience...

Page 5: ...r cooker it may generate hazardous compounds Turn off the air conditioner and call your local dealer Turn on the air conditioner after the qualified service person makes sure to confirm that the leaka...

Page 6: ...operate with wet hands Never touch the internal parts of the remote controller Touching certain internal parts will cause electric shocks and damage to the remote controller Consult your local dealer...

Page 7: ...TIME This display shows PROGRAMMED TIME of the air conditioner start or stop 6 DISPLAY SWING FLAP Refer to page 9 10 7 DISPLAY FAN SPEED The display shows the set fan speed 8 DISPLAY INSPECTION When...

Page 8: ...discolored and may fail to display information CAUTIONS Make sure to turn off the unit and disconnect the power supply breaker when taking care of the air conditioner Unless the power supply is disco...

Page 9: ...the indoor unit is under centralized control it is necessary to switch the remote controller s setting In this case contact your local dealer 5 OPERATION RANGE If the temperature or the humidity is b...

Page 10: ...d the system starts or stops OPERATION The fan may keep on running for about 1 minute after the heating operation stops for removing the heat in the indoor unit NOTE Do not turn OFF power immediately...

Page 11: ...PERATION LAMP on the light receiving unit indicator lights Leave it as it stands and wait for a while The remote controller displays the fan speed that is set The air discharge direction becomes horiz...

Page 12: ...h time this button is pressed set temperature lowers 1 C Temperature cannot be set in FAN OPERATION and PROGRAM DRY OPERATION modes In case of AUTOMATIC OPERATION In AUTOMATIC OPERATION mode the relat...

Page 13: ...outdoor unit Description of airflow direction settings and operation The range of movement of the airflow direction blades varies by indoor unit model Consult the dealer of purchase for details Airfl...

Page 14: ...ou want to cancel again and then cancel it For example When the timer is programmed to stop the system after 3 hours and start the air conditioner after 4 hours the air conditioner will stop after 3 h...

Page 15: ...ations for other units to a indoor unit Outdoor unit Indoor unit Assign cool heat selection privilege to an indoor unit Outdoor unit Indoor unit Assign cool heat selection privilege to an indoor unit...

Page 16: ...ntrol one remote controller controls one indoor unit system Confirm the following if your system is of the following control system type Group control system One remote controller controls up to 16 in...

Page 17: ...lown from the unit There is nothing wrong with the equipment The outdoor unit stops Because the room temperature reaches to the set temperature The indoor unit goes into fan operation II COOLING AND H...

Page 18: ...e set temperature is not proper Refer to page 9 Check if the FAN SPEED is set to LOW SPEED Refer to page 9 Check if the airflow direction is not proper Refer to page 9 10 If the problem is not solved...

Page 19: ...the indoor unit makes a long beep The malfunction code is fixed when the indoor unit makes a long beep 7 Reset of the display Press the OPERATION MODE SELECTOR button to get the display back to the no...

Page 20: ...minutes after the safety breaker is switched off Do not touch live parts when carrying out this work CAUTION Refer also to the installation manual attached to the indoor unit and the installation manu...

Page 21: ...be exposed to moisture or direct sunlight When operating point the transmitting part of the remote controller in the direction of the receiver Refer to the operation manual attached to this kit The ma...

Page 22: ...battery insertion 2 Check the model name of the model nameplate which is stuck on the indoor unit body Refer to the following table to find the corresponding 4 digit initial setting value Indoor unit...

Page 23: ...or the receiver and the wireless remote controller This includes an individual remote controller control using the group operation For the wiring for the group operation please refer to the installati...

Page 24: ...by an external control such as centralized control Since the setting acceptance is hard to discriminate with such circumstances there are two setting options provided to enable discriminating by a be...

Page 25: ...remote controller operation Set the Unit No of the receiver and the wireless remote controller to be equal If the settings differs the signal from the remote controller cannot be transmitted 3 Instal...

Page 26: ...ribed in manual supplied with the decoration panel The corner where the wireless kit belongs is set by the two square marks Then remove the plastic corner cover 2 Break off the plastic cover from back...

Page 27: ...ting can be changed to half the time between 2 filter cleaning display indications Long life filter Light 2 500 hrs Heavy 1 250 hrs 3 Setting for display of time between 2 filter cleaning display indi...

Page 28: ...3 Turn the power on at least 6 hours before operating the unit 4 Set to the cooling operation using the remote controller and then start the operation by pressing the ON OFF button 5 Press the button...

Page 29: ...26 NOTE...

Page 30: ...27 NOTE...

Page 31: ......

Page 32: ...P 57 7P M19N117 2006 HT The two dimensional bar code is a manufacturing code The two dimensional bar code is a manufacturing code...