background image

BYCQ14 BYCQ140D7GFW1 

Installation manual

Self cleaning decoration panel

4P310441-1C – 2017.05

8

7.  Attaching suction grille and 

decoration corner covers

The suction grill can be rotated and attached in two directions, 

either one of which is selectable.

If a number of units are installed, adjust the directions of the suction 

grilles if necessary. Make directional changes as well at the request 

of the customer.

7-1  Attaching suction grille

Select either the hook (A) or (B), and hook the claws of the 

suction grille.

Note

The suction grille may be damaged if the wrong hooking side is 

selected.

7-2  Hook (A)

(1) 

Set the suction grille to an angle of approximately 45° and put 

the hooks (in three points) onto the panel.

45°

Panel

Panel

Suction 

grille

Suction 

grille

SUCTION GRILLE HOOKING SIDE

Suction grille mounting angle

Display on

SUCTION GRILLE HOOKING SIDE

(2) 

As shown in the illustration, hook the fall prevention cords for 

the suction grille to the corner clasps (on two corners).

Change the directions of 

the fall prevention cords.

Suction grille

Clasp

Fall prevention cord

Clasp

Bend the 

clasp inward.

Fall prevention cord

(3) Connect the flexible hose (accessory (2)) onto the panel side.

 

(The flexible hose (accessory (2)) has no directionality constraint.)

Flexible hose junction 

on the panel side

Flexible hose

(accessory (2)) 

Flexible hose junction 

on the panel side

Fit the claws into the 

hooks (in two points) 

securely.

Hooks 

(2 points)

Note

Check that the claws are engaged securely. Otherwise, a dust 

collection failure may result.

(4) Press fit the flexible hose connected in (3) into the panel.

 

(Pay attention so that the hose will not be caught by the 

suction grille closed.)

Note

Be sure not to break the flexible hose when press fitting the 

flexible hose.

Flexible 

hose 

To suction grille

Press fit the 

flexible hose 

along the shape 

of the corner.

(5) Connect the opposite end of the flexible hose connected in (3) 

onto the suction grille side.

Rotate the flexible hose joint on the suction grille side 

according to the mounting direction of the suction grille as 

shown in the illustration.

Flexible hose joint on 

the suction grille side

Flexible hose 

joint on the 

suction grille side

Flexible hose

Connect the 

hose securely.

Note

Check that the claws are engaged securely. Otherwise, a dust 

collection failure may result.

Summary of Contents for BYCQ140D7GW1

Page 1: ...Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel INSTALLATION MANUAL BYCQ140D7GW1 BYCQ140D7GFW1...

Page 2: ...all the indoor and outdoor units power cord remote controller wiring and transmission wiring at least 1 m away from TV or radio sets This is for the prevention of TV and radio interference Depending o...

Page 3: ...er Be sure to hand the customer the operation manual as well as the installation manual Did you hand the customer the connecting pipe and attachment and ask the customer to keep them Point of operatio...

Page 4: ...the panel together with the accessories attached to the backside of the protective corrugated cardboard Protective corrugated cardboard top The accessories are on the backside Protective corrugated ca...

Page 5: ...tric shock may be received CAUTION Conduct the following work after installing the indoor unit Install the indoor unit according to the installation manual provided with the indoor unit 5 1 Attaching...

Page 6: ...atching brackets of the suction port of the panel on the internal circumference side to the hooks of the indoor unit Note Leave your hands after confirming through the check window that the temporary...

Page 7: ...lation manual of the indoor unit to conduct the work 6 3 Checking panel 1 Remove sealing of panel 1 2 1 2 3 4 1 Remove seal of panel 2 Insert the seal until the seal comes in contact with the claw 3 C...

Page 8: ...illustration 1 2 3 4 5 1 Clasp 2 Hooked fall prevention cord 3 Panel 4 Fall prevention cord 5 Dust box 2 Attach the dust box in the order opposite to the procedure in 4 3 Removal of dust box on page...

Page 9: ...Fall prevention cord Clasp Bend the clasp inward Fall prevention cord 3 Connect the flexible hose accessory 2 onto the panel side The flexible hose accessory 2 has no directionality constraint Flexib...

Page 10: ...nect the flexible hose accessory 2 onto the panel side The flexible hose accessory 2 has no directionality constraint Flexible hose junction on the panel side Fit the claws into the hooks in two point...

Page 11: ...auto cleaning of the self clean panel Operation mode Description 1 Scheduled timer operation Performs filter auto cleaning during the designated period selected from eight periods 2 00 00 to 03 00 op...

Page 12: ...er on The panel will go into initialization operation after the power is turned on 10 3 Conduct the test operation of the panel two minutes after the power is turned on Confirm the cleaning operation...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...Copyright 2012 Daikin 4P310441 1C 2017 05...

Reviews: