background image

3. 

Press 

 to confirm the selection.

 

Result:

   is blinking.

4. 

Press the WPS button on your communication device 
(e.g.router) within approximately 1 minute. Refer to the 
manual of your communication device. 

Result:

 The timer LED is blinking.

5. 

Press 

 to exit the menu.

Result:

 The display will return to the default screen.

Note:

 If the blinking of the timer lamp does not slow down and 

the timer lamp goes out, repeat steps 1 through 5.

If connection is still impossible, use the procedures in “To 
connect the wireless adapter to your device directly” to perform 

setting.

To connect the wireless adapter to your device 

directly

1. 

Hold 

 for at least 5 seconds in the default screen. 

Result:

 The confirmation display (menu 

 ) appears.

2. 

Press repeatedly 

 or 

 until the AP setting display 

(menu   ) appears.

3. 

Press 

 to confirm the selection.

 

Result:

   is blinking.

4. 

Connect with your smart device to the access point in the 
same way as to a standard wireless network.

• 

Select the SSID (DaikinAP*****) printed on the unit or 
in the accessory set, and enter the password.

Result:

 The operation and timer LEDs are blinking.

5. 

Press 

 to exit the menu.

Result:

 The display will return to the default screen.

6. 

Open the application and tap “Configure the wireless 
connection”, then connect to the home network following 

the instructions on the screen.

7. 

Connect your smartphone to the home network.

To reset the connection setting to the factory default

Reset the connection setting to the factory default in case you 
want to:

• 

switch between the WPS and the AP connection option,

• 

disconnect the Wi-Fi adapter and the communication device 
(e.g.router) or smart device,

• 

repeat the setting if the connection was unsuccessful.

1. 

Hold 

 for at least 5 seconds in the default screen. 

Result:

 The confirmation display (menu 

 ) appears.

2. 

Press repeatedly 

 or 

 until the A display (menu  ) 

appears.

3. 

Hold 

 for at least 2 seconds to confirm the selection.

 

Result:

   is blinking. The setting is reset to the factory default.

4. 

Press 

 to exit the menu. 

Result:

 The display will return to the default screen.

To turn off the wireless connection

You can turn off the wireless connection using:

• 

the remote controller,

• 

the wireless adapter ON/OFF button on the unit.

To use the wireless adapter ON/OFF switch

1. 

Press the wireless adapter ON/OFF switch. 

Result:

 The wireless adapter communication is OFF.

Note:

 Press the ON/OFF switch again to turn on the wireless 

adapter.

To use the remote controller

1. 

Hold 

 for at least 5 seconds in the default screen. 

Result:

 The confirmation display (menu 

 ) appears.

2. 

Press repeatedly 

 or 

 until the OFF menu appears.

3. 

Hold 

 for at least 2 seconds to confirm the selection.

 

Result:

 

 is blinking. Communication is OFF. The 

operation and timer LEDs are blinking.

4. 

Press 

 to exit the menu.

Result:

 The display will return to the default screen.

15 

01_EN_3P620957-1.indd   15

26-Jun-20   10:17:42 AM

Summary of Contents for CTXJ25TVMAW

Page 1: ...r round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS CTXJ25TVMAW CTXJ35TVMAW CTXJ50TVMAW CTXJ60TVMAW CTXJ25TVMAK CTXJ35TVMAK CTXJ50TVMA...

Page 2: ...QUIET operation 17 6 1 4 COOL HEAT mode lock 17 6 1 5 Priority room setting Not available on some models 17 7 Maintenance and service 17 7 1 Overview Maintenance and service 17 7 2 To clean the indoor...

Page 3: ...us gas Do not use the air conditioner until a qualified service person confirms that the leakage has been repaired Do not attempt to install or repair the air conditioner yourself Improper workmanship...

Page 4: ...n adverse influence on the performance product quality and life of the air conditioner This appliance is not intended to be used by persons with reduced physical sensory or mental capabilities or with...

Page 5: ...h2sec d a g m h c b n l f e i j k p o a Signal transmitter b LCD display c Temperature adjustment button d ON OFF button e Vertical swing button and menu push 2 seconds f Horizontal swing button g Com...

Page 6: ...s with tap water and seek the attention of a medical professional Keep batteries out of reach of children In the event that batteries are swallowed seek the immediate attention of a medical profession...

Page 7: ...selected setting press Result The brightness setting is changed Note The display automatically returns to the default screen after 60 seconds To return to the default screen sooner press twice 3 5 To...

Page 8: ...y is in the room Powerful To cool down or heat up the room quickly Feature Tasks ON timer OFF timer To automatically turn ON or OFF the system Weekly timer To automatically turn ON or OFF the system o...

Page 9: ...side to side Stays in a fixed position CAUTION ALWAYS use a remote controller to adjust the position of the flaps and louvres When the flaps and louvres are swinging and you move them forcibly by han...

Page 10: ...selected function takes priority If the Vertical automatic swing is selected Comfort airflow operation will be cancelled To turn ON OFFVertical airflow function 1 Press for at least 2 seconds Result T...

Page 11: ...efficient operation by limiting the maximum power consumption value This function is useful for cases in which attention should be paid to ensure a circuit breaker will not trip when the product runs...

Page 12: ...use OFF timer and ON timer in combination INFORMATION Programme the timer again in case of A circuit breaker has turned the unit off A power failure After replacing batteries in the remote controller...

Page 13: ...remote controller at the indoor unit and check for a receiving tone when setting the Weekly timer operation See 2 2 3 To operate the remote controller on page 5 INFORMATION The clock MUST be set corre...

Page 14: ...ll reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservation number to...

Page 15: ...bile Controller application 1 Open Google Play for appliances using Android App Store for appliances using iOS 2 Search for Daikin Mobile Controller 3 Follow the directions on the screen to install 4...

Page 16: ...smartphone to the home network To reset the connection setting to the factory default Reset the connection setting to the factory default in case you want to switch between the WPS and the AP connect...

Page 17: ...the room temperature properly for a comfortable environment Avoid excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using th...

Page 18: ...e of the priority room takes precedence you can select a different operation mode from other rooms Example Room A is the priority room in this example When COOL operation is selected in room A while o...

Page 19: ...ELECTROCUTION Before cleaning be sure to stop the operation turn the circuit breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean with a soft cloth If it i...

Page 20: ...FORMATION Clean the filter with water every 6 months 1 Remove the dust from the filter with a vacuum cleaner INFORMATION Replace the filter every 3 years Dispose of the old filter as non flammable was...

Page 21: ...RMATION It is recommended to have periodical maintenance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the user In certain operating cond...

Page 22: ...to set the temperature on page 7 Check if the airflow direction setting is appropriate Refer to 4 3 3 Airflow direction on page 8 Check if the air inlet or outlet of the outdoor or indoor unit is NOT...

Page 23: ...possible to fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date possibly listed o...

Page 24: ...ription Indoor unit PCB abnormality Freeze up protection or high pressure control Fan motor DC motor abnormality Streamer unit error Indoor heat exchanger thermistor abnormality Opening or closing fro...

Page 25: ...wireless adapter connection status on page 14 Try to resetting to the factory default and repeat the setting See To reset the connection setting to the factory default on page 15 9 Disposal NOTICE Do...

Page 26: ...MEMO 25 01_EN_3P620957 1 indd 25 26 Jun 20 10 17 50 AM...

Page 27: ...01_EN_3P620957 1 indd 26 26 Jun 20 10 17 50 AM...

Page 28: ...3P620957 1 M20N052 2006 HT The two dimensional bar code is a manufacturing code 00_CV_3P620957 1 indd 2 23 Jun 20 11 21 05 AM...