6
|
Unit installation
Installer reference guide
25
FTXM20~42+ATXM20~35R2/5V1B + FTXM50~7
ATXM50R2V1B
Daikin room air conditioner
4P518023-8G – 2020.06
2
Remove the front panel by sliding it to the left or the right and pulling it
toward you.
Result:
The front panel shaft on 1 side will be disconnected.
3
Disconnect the front panel shaft on the other side in the same manner.
a
a
Front panel shaft
6.2.2 To open the service cover
1
Remove 1 screw from the service cover.
2
Pull out the service cover horizontally away from the unit.
a
b
a
Service cover screw
b
Service cover
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4 (±0.2) N•m.
6.2.3 To remove the front grille
CAUTION
Wear adequate personal protective equipment (protective gloves, safety glasses,…)
when installing, maintaining or servicing the system.
1
Remove the front panel to remove the air filter.
2
For class 50~71
remove the flap (horizontal blade). Push the blade on its left
side to the centre and unhook it. Push blade on its right side to centre to
unhook it from shaft. Disconnect the 2 centre connection points.
1
2
3
4
3
Remove 2 screws (class 15~42) or 3 screws (class 50~71) from the front grille.
4
Push down the 3 upper hooks marked with a symbol with 3 circles.