Field Setting
Si18-525B
166
Test Operation
3. Field Setting
3.1
Field Setting from Outdoor Unit
3.1.1
Setting by dip switches
The following field settings are made by dip switches on PCB.
Dipswitch
Setting item
Description
No.
Setting
DS1-1
ON
Cool / Heat
change over
setting
Used to set cool / heat change over setting by
remote controller equipped with outdoor unit.
OFF (Factory set)
DS1-2
~DS1-4
ON
Not used
Do not change the factory settings.
OFF (Factory set)
DS2-1
~4
ON
Not used
Do not change the factory settings.
OFF (Factory set)
Caution
DIP switch Setting after changing the main PCB (A1P) to spare parts PCB.
When you change the main PCB (A1P) to spare parts PCB, please carry out the following
setting.
The spare parts PCB is different from the PCB on factory shipment above in a way of setting.
When you exchange to the spare parts PCB, make sure that you change setting referring the
following table.
DIP Switch Detail
1 2 3 4
1 2 3 4
DS1
DS2
ON
OFF
ON
OFF
DS No.
DS1-1
Item
Contents
Not used
Do not change the factory setting
The following setting is performed according to capability of the outdoor unit.
Cool/Heat change
over setting
The Cool/Heat change over setting is carried out by COOL/HEAT
changeover remote controller fitted to outdoor unit.
The Cool/Heat change over setting is not carried out by
COOL/HEAT changeover remote controller fitted to outdoor unit.
Cooling only
Heat-pump
DS1-2
Cooling only/Heat-
pump setting
ON
ON
OFF
Connect BP unit
Not connect BP unit
DS1-3
BP Unit
ON
OFF
OFF
DS1-4
DS2-1
HP setting
(Horse power)
DS2-1
DS2-2
DS2-2
DS2-3
DS2-4
ON
OFF
OFF
ON
OFF
OFF
4HP
5HP
6HP
OFF
OFF
OFF
ON
DS2-3
OFF
OFF
DS2-4
Summary of Contents for D-Series
Page 1: ...Si18 525B Applied Models Super Multi Plus Cooling only Super Multi Plus Heat Pump D Series ...
Page 33: ...List of Functions Si18 525B 20 List of Functions ...
Page 71: ...Specifications Si18 525B 58 Specifications ...
Page 117: ...Refrigerant Flow for Each Operation Mode Si18 525B 104 Refrigerant Circuit ...
Page 171: ...Indoor Unit SkyAir Models Si18 525B 158 Function ...
Page 207: ...Test Operation and Field Setting for RA Indoor Unit Si18 525B 194 Test Operation ...
Page 336: ...Si18 525B Service Check Function Troubleshooting 323 ...
Page 469: ...Wiring Diagrams Si18 525B 456 Appendix ...
Page 475: ...Si18 525B vi Index ...