Instruction
Si18-525B
202
Operation Manual
Outdoor Unit
Indoor Unit
1. Air filter
2. Titanium Apatite Photocatalytic
Air-Purifying Filter:
• These filters are attached to the inside of the air
filters.
3. Air inlet
4. Front panel
5. Panel tab
6. Room temperature sensor:
• It senses the air temperature around the unit.
7. INTELLIGENT EYE sensor:
• It detects the movements of people and auto-
matically switches between normal operation
and energy saving operation.
8. Display
9. Air outlet
10. Flaps (horizontal blades)
11. louvers (vertical blades):
• The louvers are inside of the air outlet.
12. Indoor Unit ON/OFF switch:
• Push this switch once to start operation.
Push once again to stop it.
• The operation mode refers to the following
table.
• This switch is useful when the remote controller
is missing.
13. Operation lamp (green)
14. TIMER lamp (yellow)
15. INTELLIGENT EYE lamp (green)
16. Signal receiver:
• It receives signals from the remote controller.
• When the unit receives a signal, you will hear a
short beep.
• Operation start .............beep-beep
• Settings changed ..........beep
• Operation stop ..............beeeeep
Outdoor Unit
17. Air inlet: (Back and side)
18. Air outlet
19. Refrigerant piping and inter-unit cable
20. Drain hose
21. Earth terminal:
• It is inside of this cover.
22. Outside air temperature sensor:
• It senses the ambient temperature around the
unit.
Appearance of the outdoor unit may differ from some models.
19
22
20
21
18
17
Mode
Temperature
setting
Air flow
rate
FTK
COOL
22˚C
AUTO
FTX
AUTO
25˚C
AUTO
Summary of Contents for D-Series
Page 1: ...Si18 525B Applied Models Super Multi Plus Cooling only Super Multi Plus Heat Pump D Series ...
Page 33: ...List of Functions Si18 525B 20 List of Functions ...
Page 71: ...Specifications Si18 525B 58 Specifications ...
Page 117: ...Refrigerant Flow for Each Operation Mode Si18 525B 104 Refrigerant Circuit ...
Page 171: ...Indoor Unit SkyAir Models Si18 525B 158 Function ...
Page 207: ...Test Operation and Field Setting for RA Indoor Unit Si18 525B 194 Test Operation ...
Page 336: ...Si18 525B Service Check Function Troubleshooting 323 ...
Page 469: ...Wiring Diagrams Si18 525B 456 Appendix ...
Page 475: ...Si18 525B vi Index ...