Instruction
Si18-525B
292
Operation Manual
If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING ONLY TYPE
HEAT PUMP TYPE
D B: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the remote con-
troller is 16˚C to 32˚C.
Regarding places for installation
• Is the air conditioner installed at a well-ventilated
place where there are no obstacles around?
• Do not use the air conditioner in the following
places.
a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring
resort
d. Where there are considerable voltage fluctua-
tions such as a factory or plant
e. Vehicles and vessels
f
. Where there is much spray of oil and vapor
such as a cookery, etc.
g. Where there are machines generating electro-
magnetic waves
h. Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer.
3. OPERATION RANGE
TEMPERATURE[˚C]
OUTDOOR
INDOOR
–5 to 46(DB)
21 to 32(DB)/
14 to 23(WB)
OPERATION
TEMPERATURE[˚C]
OUTDOOR
INDOOR
COOLING
–5 to 46(DB)
21 to 32(DB)/
14 to 23(WB)
HEATING
–14 to 21(DB)/
–15 to 15.5(WB)
14 to 28(DB)
4. INSTALLATION SITE
Regarding wiring
• All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by yourself.
• Make sure that a separate power supply cir-
cuit is provided for this air conditioner and
that all electrical work is carried out by quali-
fied personnel according to local laws and
regulations.
Pay attention to running noises, too
• Are the following places selected?
a. A place that can sufficiently withstand the
weight of the air conditioner with less running
noises and vibrations.
b. A place where the hot wind discharged from the
air outlet of the outdoor unit and the running
noises.
• Are you sure that there are no obstacles near
the air outlet of the outdoor unit?
Such obstacles may result in declined perfor-
mance and increased running noises.
• If abnormal noises occur in use, consult your
dealer.
Regarding drainage of drain piping
• Is the drain piping executed to perform com-
plete drainage?
If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation,
chances are that dust and dirt are clogged in the
pipe. This may result in a water leakage from the
indoor unit. Under such circumstances, stop the
operation of the air conditioner, and then consult
your dealer or our service station.
Summary of Contents for D-Series
Page 1: ...Si18 525B Applied Models Super Multi Plus Cooling only Super Multi Plus Heat Pump D Series ...
Page 33: ...List of Functions Si18 525B 20 List of Functions ...
Page 71: ...Specifications Si18 525B 58 Specifications ...
Page 117: ...Refrigerant Flow for Each Operation Mode Si18 525B 104 Refrigerant Circuit ...
Page 171: ...Indoor Unit SkyAir Models Si18 525B 158 Function ...
Page 207: ...Test Operation and Field Setting for RA Indoor Unit Si18 525B 194 Test Operation ...
Page 336: ...Si18 525B Service Check Function Troubleshooting 323 ...
Page 469: ...Wiring Diagrams Si18 525B 456 Appendix ...
Page 475: ...Si18 525B vi Index ...