Instruction
Si18-525B
310
Operation Manual
VII.DUST FROM THE UNITS
• Dust may blow out from the unit after starting
operation from long resting time.
Dust absorbed by the unit blows out.
VIII.THE UNITS GIVE OFF ODORS
The unit absorbs the smell of rooms, furniture,
cigarettes, etc., and then emits them.
IX.THE LIQUID CRYSTAL OF THE REMOTE CON-
TROLLER SHOW “
”
• It happens immediately after the main power
supply switch is turned on.
This shows that the remote controller is in normal
condition.
This continues temporary.
I. If one of the following malfunctions occurs,
take the measures shown below and contact
your Daikin dealer.
The system must be repaired by a qualified service
person.
WARNING
When the air conditioner is in abnormal con-
ditions (smell of something burning, etc),
unplug the power cord from the outlet, and
contact your dealer
Continued operation under such circumstances
may result in a failure, electric shock, and fire.
• If a safety device such as a fuse, a breaker, or an
earth leakage breaker frequently actuates, or ON/
OFF switch does not properly work.
Measure: Turn off the main power switch
• If water leaks from unit.
Measure: Stop the operation.
• If the display “
” (INSPECTION), “UNIT No.”,
and the OPERATION lamp flash and the “MAL-
FUNCTION CODE” appears.
Measure: Notify your Daikin dealer and inform
him/her of the display.
10. TROUBLE SHOOTING
II. If the system does not properly operate
except for the above mentioned case, and
none of the above mentioned malfunctions is
evident, investigate the system according to
the following procedures.
1. If the system does not operate at all.
• Check if there is a power failure.
Wait until power is restored. If power failure
occurs during operation, the system automati-
cally restarts immediately after the power sup-
ply recovers.
• Check if the fuse has blown or breaker has
worked.
Change the fuse or set the breaker.
2. If the system stops operating after operating
the system.
• Check if the air inlet or outlet of outdoor or
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-venti-
lated.
• Check if the air filter is clogged.
Ask a qualified service person to clean the air
filters (Refer to MAINTENANCE).
3. The system operates but it does not suffi-
ciently cool or heat.
• If the air inlet or outlet of the indoor or the out-
door unit is blocked with obstacles.
Remove the obstacle and make it well-venti-
lated.
• If the air filter is clogged.
Ask a qualified service person to clean the air
filters (Refer to MAINTENANCE).
• If the set temperature is not proper (Refer to
ADJUSTMENT).
• If the FAN SPEED button is set to LOW
SPEED (Refer to ADJUSTMENT).
• If the air flow angle is not proper (Refer to AIR
FLOW DIRECTION ADJUST).
• If the doors or the windows are open.
Shut doors or windows to prevent wind from
coming in.
• If direct sunlight enters the room (when cool-
ing).
Use curtains or blinds.
• When there are too many inhabitants in the
room (when cooling).
Cooling effect decreases if heat gain of the
room is too large.
• If the heat source of the room is excessive
(when cooling).
Cooling effect decreases if heat gain of the
room is too large.
OPERATION lamp
INSPECTION
display
MALFUNCTION CODE
INDOOR UNIT
No. in which a
malfunction occurs.
UNIT No.
C
L
H
3PN05140-1T
Summary of Contents for D-Series
Page 1: ...Si18 525B Applied Models Super Multi Plus Cooling only Super Multi Plus Heat Pump D Series ...
Page 33: ...List of Functions Si18 525B 20 List of Functions ...
Page 71: ...Specifications Si18 525B 58 Specifications ...
Page 117: ...Refrigerant Flow for Each Operation Mode Si18 525B 104 Refrigerant Circuit ...
Page 171: ...Indoor Unit SkyAir Models Si18 525B 158 Function ...
Page 207: ...Test Operation and Field Setting for RA Indoor Unit Si18 525B 194 Test Operation ...
Page 336: ...Si18 525B Service Check Function Troubleshooting 323 ...
Page 469: ...Wiring Diagrams Si18 525B 456 Appendix ...
Page 475: ...Si18 525B vi Index ...