List of Malfunction Code
Si18-525B
328
Troubleshooting
Outdoor
Unit
L4
Malfunction of inverter radiating fin temperature rise
—
—
—
L5
Inverter compressor motor grounding, short circuit
—
—
—
L6
Compressor motor coil grounding on short circuit
—
—
—
—
L8
Inverter current abnormal
—
—
—
L9
Inverter start up error
—
—
—
LA
Malfunction of power unit
—
—
—
—
LC
Malfunction of transmission between inverter and
control PC board
—
—
—
P1
Inverter over-ripple protection
—
—
—
—
P4
Malfunction of inverter radiating fin temperature rise
sensor
—
—
—
PJ
Faulty combination inverter and fan driver,
Malfunction of capacity setting
—
—
—
System
U0
Low pressure drop due to refrigerant shortage or
electronic expansion valve failure
—
—
—
U1
Reverse phase / open phase
—
—
—
—
U2
Power supply insufficient or instantaneous failure
—
—
—
U3
Check operation is not conducted.
—
—
—
U4
Malfunction of transmission between indoor and BP
units
—
—
—
U5
Malfunction of transmission between remote
controller and indoor unit
—
—
—
U5
Failure of remote controller PC board or setting
during control by remote controller
—
—
—
—
U7
Malfunction of transmission between outdoor units
—
—
—
—
U8
Malfunction of transmission between master and
slave remote controllers (malfunction of slave remote
controller)
—
—
—
U9
Malfunction of transmission between indoor unit and
outdoor unit in the same system
—
—
—
UA
Mismatching of indoor unit, BP unit and outdoor unit
etc.
—
—
UC
Address duplication of central remote controller
—
—
—
—
UE
Malfunction of transmission between central remote
controller and indoor unit
—
—
—
—
UF
Refrigerant system not set, incompatible wiring /
piping
—
—
—
UH
Malfunction of system, refrigerant system address
undefined
—
—
—
UJ
Transmission error between outdoor unit and BP unit
—
—
—
9
: Blink
8
: ON
7
: OFF
Malfunction
code
Malfunction contents
Page Referred
RA Indoor
Unit
SkyAir
Indoor Unit
BP Unit
Outdoor
Unit
The system operates for malfunction codes indicated in black squares, however, be sure to check and repair.
Summary of Contents for D-Series
Page 1: ...Si18 525B Applied Models Super Multi Plus Cooling only Super Multi Plus Heat Pump D Series ...
Page 33: ...List of Functions Si18 525B 20 List of Functions ...
Page 71: ...Specifications Si18 525B 58 Specifications ...
Page 117: ...Refrigerant Flow for Each Operation Mode Si18 525B 104 Refrigerant Circuit ...
Page 171: ...Indoor Unit SkyAir Models Si18 525B 158 Function ...
Page 207: ...Test Operation and Field Setting for RA Indoor Unit Si18 525B 194 Test Operation ...
Page 336: ...Si18 525B Service Check Function Troubleshooting 323 ...
Page 469: ...Wiring Diagrams Si18 525B 456 Appendix ...
Page 475: ...Si18 525B vi Index ...