Si18-525B
Wiring Diagrams
Appendix
441
2.
Wiring Diagrams
2.1
Outdoor Units
RMKS112/140/160DVM, RMKS112/140/160DV1A
POWER SUPPLY
VM
V1A
220-230V~50/60Hz
220-240V~50Hz
THE POSITION OF
COMPRESSOR
TERMINAL
OF WIRE
THE ENTRANCE
L1R
A2P
A3P
N
L
U
YLW
V1T
N
P2
P1
P3
P4
+
-
W
V2R
V
E1
+
C2
Z1C
K1M
X1M
RED
LB
LC
RED
LA
M1C
+
+
U
U
L
RED
N
V
V
3~
MS
R1
+
+
WHT
Z1F
GRN/YLW
C3
C1
W
W
K2R
F1U
BLU
NB
BLU
R2
BLU
NC
NA
N
-
N
-
BRN
N=5
V1R
M1F
X1A
Z2C
WHT(RED MARKING)
3~
MS
PS
X206A
RED
RED
RED
X60A
M2F
Z3C
3~
MS
S1PH
P<
X207A
HAP
WHT
WHT
WHT
WHT
X205A
RED
BLU
X1A
A1P
X25A
1
Y1S
R3T
t
°
X2A
X1M
A
X34A
Y2S
K1R
C/H SELECTOR
X3A
B
K2R
1
R2T
t
°
C
R4T
TO BP UNIT
F1
t
°
E1HC
F2
X6A
BP UNIT
X37A
(F1)(F2)
R5T
TO OUT/D UNIT
t
°
NOTE)8
F1
HAP
X22A
BS1
K5R
H1P
F2
BS2
OFF
OFF
H2P
ON
ON
H3P
t
°
BS3
1
1
H4P
T1R
DS2
DS1
2
2
H5P
3
3
BS4
H6P
4
4
H7P
BS5
X23A
FRONT
A1P
X26A
X45A
X46A
X28A
X44A
X1M
NOTE)4
A3P
X24A
X1M
A
t
°
S1NPL
S1NPH
6
6
VIEW A
L1R
Y2E
R1T
Y1E
A2P
M
M
A2P
A3P
HAP
K2R
HAP
K2R
K5R
R2
M2F
E1HC
R2T
R4T
R5T
R3T
BS1~5
Y2E
Y2S
A1P
F1U
H1P~7P
K1M
K1R
L1R
V1T
PS
R1
S1NPL
S1PH
V1R, V2R
M1F
M1C
R1T
S1NPH
T1R
Y1E
Y1S
Z1C~3C
Z1F
X1M
X1M
DS1,2
C1,2,3
L-RED
POWER MODULE (A2P)
CRANKCASE HEATER
PUSH BUTTON SWITCH
REACTOR
MOTOR (FAN)
MOTOR (FAN)
MOTOR (COMPRESSOR)
PRESSURES WITCH (HIGH)
PRESSURE SENSOR (LOW)
PILOT LAMP(SERVICE MONITOR-ORANGE)
PILOT LAMP(SERVICE MONITOR-GREEN) (A2P)
PILOT LAMP(SERVICE MONITOR-GREEN) (A1P)
TRANSFORMER(220-240V/24V)
PRESSURE SENSOR (HIGH)
PRINTED CIRCUIT BOARD (NOISE FILTER)
ELECTRONIC EXPANSION VALVE (MAIN)
ELECTRONIC EXPANSION VALVE (SUB COOL)
FUSE( 6.3A/250V)
MAGNETIC RELAY (K1M)
MAGNETIC CONTACTOR (M1C)
CAPACITOR
DIP SWITCH
PRINTED CIRCUIT BOARD (INV)
PRINTED CIRCUIT BOARD (MAIN)
NOISE FILTER (WITH SURGE ABSORBER)
THERMISTOR (SUCTION)
[H2P]PREPARE, TEST ------------ FLICKERING
TERMINAL STRIP (CONTROL) (A1P)
TERMINAL STRIP (POWER SUPPLY)
SOLENOID VALVE (RECEIVER GAS PURGE)
SOLENOID VALVE (HOT GAS)
SWITCHING POWER SUPPLY
IGBT (A2P)
NOISE FILTER (FERRITE CORE)
MAGNETIC RELAY (E1HC)
MAGNETIC RELAY (Y2S)
MAGNETIC RELAY (Y1S)
RESISTOR (CURRENT SENSOR)
RESISTOR (CURRENT LIMITING)
THERMISTOR (AIR)
THERMISTOR (HEAT EXC. OUTLET)
THERMISTOR (HEAT EXC. DEICER)
THERMISTOR (M1C DISCHARGE)
(MODE, SET, RETURN, TEST, RESET)
MALFUNCTION DETECTION --- LIGHT UP
T
N-BLU
3D048943
NOTES)1.THIS WIRING DIAGRAM IS APPLIED ONLY TO THE OUTDOOR UNIT.
2. :FIELD WIRING.
3. :TERMINAL STRIP , :MOVABLE CONNECTOR :FIXED CONNECTOR :TERMINAL
:PROTECTIVE EARTH (SCREW) :NOISELESS EARTH
4.WHEN USING THE OPTION ADAPTOR, REFER TO THE INSTALLATION MANUAL.
5.REFER TO"OPERATION CAUTION LABEL"(ON BACK OF FRONT PLATE), HOW TO USE BS1~BS5 AND DS1•2 SWITCH.
6.WHEN OPERATING, DON’T SHORT CIRCUIT FOR PROTECTION DEVICE. (S1PH)
7.COLORS BLU:BLUE BRN:BROWN GRN:GREEN RED:RED WHT:WHITE YLW:YELLOW.
8.REFER TO THE INSTALLATION MANUAL, FOR CONNECTION WIRING TO BP UNIT-OUTDOOR TRANSMISSION F1 F2.
Summary of Contents for D-Series
Page 1: ...Si18 525B Applied Models Super Multi Plus Cooling only Super Multi Plus Heat Pump D Series ...
Page 33: ...List of Functions Si18 525B 20 List of Functions ...
Page 71: ...Specifications Si18 525B 58 Specifications ...
Page 117: ...Refrigerant Flow for Each Operation Mode Si18 525B 104 Refrigerant Circuit ...
Page 171: ...Indoor Unit SkyAir Models Si18 525B 158 Function ...
Page 207: ...Test Operation and Field Setting for RA Indoor Unit Si18 525B 194 Test Operation ...
Page 336: ...Si18 525B Service Check Function Troubleshooting 323 ...
Page 469: ...Wiring Diagrams Si18 525B 456 Appendix ...
Page 475: ...Si18 525B vi Index ...