Si18-525B
Printed Circuit Board Connector Wiring Diagram
Printed Circuit Board Connector Wiring Diagram
71
1.3.3 FTK(X)S 50~71 B, FTXS 50~71 D, FTKD 50~71 F
Connectors
PCB(1) (
Control PCB
)
PCB(2) (
Signal Receiver PCB
)
PCB(3) (
Buzzer PCB
)
PCB(4) (
Display PCB
)
PCB(5) (
INTELLIGENT EYE sensor PCB
)
Note:
Other designations
PCB(1) (Control PCB)
PCB(2) (Signal Receiver PCB)
PCB(3) (Buzzer PCB)
PCB(4) (Display PCB)
1)
S1
Connector for DC fan motor
2)
S6
Connector for swing motor (horizontal blades)
3)
S8
Connector for swing motor (vertical blades)
4)
S21
Connector for
centralized control
(
HA
)
5)
S26
Connector for buzzer PCB
6)
S28
Connector for signal receiver PCB
7)
S32
Connector for heat exchanger thermistor
8)
S35
Connector for Intelligent Eye sensor PCB
1)
S29
Connector for control PCB
1)
S27
Connector for control PCB
2)
S38
Connector for display PCB
1)
S37
Connector for buzzer PCB
1)
S36
Connector for control PCB
1)
V1
Varistor
2)
JA
Address setting jumper
JB
Fan speed setting
when compressor is OFF on thermostat
JC
Power failure recovery function
∗
Refer to page 193 for detail.
3)
LED A
LED A for service monitor (green)
4)
FU1
Fuse
(3.15A)
1)
SW1 (S1W)
Forced operation ON/OFF switch
1)
RTH1 (R1T)
Room temperature thermistor
4)
LED1
LED for operation (green)
5)
LED2
LED for timer (yellow)
6)
LED3
LED for HOME LEAVE operation (red)
Summary of Contents for D-Series
Page 1: ...Si18 525B Applied Models Super Multi Plus Cooling only Super Multi Plus Heat Pump D Series ...
Page 33: ...List of Functions Si18 525B 20 List of Functions ...
Page 71: ...Specifications Si18 525B 58 Specifications ...
Page 117: ...Refrigerant Flow for Each Operation Mode Si18 525B 104 Refrigerant Circuit ...
Page 171: ...Indoor Unit SkyAir Models Si18 525B 158 Function ...
Page 207: ...Test Operation and Field Setting for RA Indoor Unit Si18 525B 194 Test Operation ...
Page 336: ...Si18 525B Service Check Function Troubleshooting 323 ...
Page 469: ...Wiring Diagrams Si18 525B 456 Appendix ...