3 Operation

Operation manual

6

D035A1/4AB + D035A4AB

Wall-mounted condensing boiler

3P469438-5M – 2019.11

3.3.4

Changing temperature setpoints

Temperature setpoints can be changed with the Right/Left dials.

To change the central heating temperature
setpoint

1

Turn the left dial while you are at the home screen. The setpoint
screen  will  appear  as  shown  below  and  the  setpoint  can  be
adjusted by turning the left dial. 

Note: 

The   icon means you are

at the setpoint screen.

2

To apply changes done, wait for 3 seconds or press the "Enter"
button. Pressing the "Cancel" button cancels the changes done.

To change the domestic hot water setpoint

1

Turn  the  right  dial  while  you  are  at  the  home  screen.  The
setpoint  screen  will  appear  as  shown  below  and  the  setpoint
can  be  adjusted  by  turning  the  right  dial. 

Note: 

The    icon

means you are at the setpoint screen.

2

To apply changes done, wait for 3 seconds or press the "Enter"
button. Pressing the "Cancel" button cancels the changes done.

NOTICE

To  be  able  to  change  the  setpoint  of  central  heating  or
domestic  hot  water,  the  corresponding  operation  mode
must  be  enabled.  If  it  is  not,  the  related  dial  has  no
function.

3.3.5

Possible central heating operation modes

Mode

Description

Boiler only

The case that the system only
contains the boiler. No room
thermostat or outdoor sensor are
connected. The central heating water
temperature setpoint is displayed. The
setpoint can be adjusted with the left
dial.

The   icon is shown on the screen
when the central heating operation
mode is enabled.

Combination with Daikin
room thermostat (DOTT )

The case that Daikin room thermostat
is connected to the boiler. Actual room
temperature is displayed. The room
temperature setpoint can be adjusted
from the user interface by means of
the left dial or from the Daikin room
thermostat.

The   icon is shown on the screen
instead of the   icon when central
heating operation mode is enabled.

outdoor sensor
(Weather compensation)

The case that outdoor sensor is
connected to the boiler. In this case,
the central heating water temperature
is regulated according to the outdoor
temperature. The virtual room
temperature setpoint is diplayed. The
virtual room temperature setpoint can
be adjusted by means of left dial.
Increasing or decreasing the setpoint
value reflects to the central heating
water temperature and the room
temperature, respectively.

The   and   icons are shown on the
screen when central heating operation
mode is enabled.

NOTICE

To enable weather compensation, the heating slope value
must  be  higher  than  "0"  (see 

"User  settings  menu:

Parameters (short)"

 [

4

 9]).

INFORMATION

If  an  outdoor  sensor  is  connected  to  the  boiler  together
with  Daikin  room  thermostat,  the  rules  of  the  case
"Combination with Daikin room thermostat" are applicable.
The  outdoor  sensor  only  provides  outdoor  temperature
data  to  the  room  thermostat  for  water  temperature
calculation.

3.3.6

About the central heating ECO mode

The  central  heating  ECO  mode  provides  more  economic  central
heating.  Main  purpose  of  the  ECO  mode  is  to  operate  the  boiler  at
the  condensing  temperature  range  so  to  increase  the  efficiency.
ECO mode can be activated at any central heating operation mode
explained above.

ECO mode can be enabled from the user settings menu (see 

"User

settings menu: Parameters (short)"

 [

4

 9]).

INFORMATION

ECO  mode  is  only  for  central  heating,  it  has  no  effect  to
domestic water heating.

When central heating ECO mode is enabled,   icon is shown on the
screen while the central heating operation mode is enabled.

Summary of Contents for D2CND028A1AB

Page 1: ...Operation manual Wall mounted condensing boiler English Operation manual Wall mounted condensing boiler D2CND028A1AB D2CND028A4AB D2CND035A1AB D2CND035A4AB D2TND028A4AB D2TND035A4AB...

Page 2: ...nted gas fired condensing boiler that can supply heat to central heating systems as well as supply domestic hot water Depending on settings it is possible to use the unit solely for hot water or solel...

Page 3: ...the boiler or other parts of the system Never attempt to perform maintenance or repair yourself Call a qualified service agent CAUTION Do not use sprays solvents chlorinated cleaning agents paint and...

Page 4: ...show the home screen of the active operation mode and the related setpoint depending on the system configuration see 3 3 3 Possible operation modes 45 Status icons Meaning of icons that appear on the...

Page 5: ...mode c Summer mode d Winter mode e Full off mode 3 3 3 Possible operation modes Operation mode Description Central heating only mode Only central heating operation mode is enabled The central heating...

Page 6: ...room temperature is displayed The room temperature setpoint can be adjusted from the user interface by means of the left dial or from the Daikin room thermostat The icon is shown on the screen instead...

Page 7: ...tion the unit must be connected to the power supply and its main gas valve must be open Any damage caused by frost is not covered by the warranty Frost Protection is enabled in all modes including sta...

Page 8: ...uel energy consumption Central Heating Last month kWh Description short Unit F12 d Fuel energy consumption Central Heating Current month kWh F13 d Fuel energy consumption Central Heating Current Year...

Page 9: ...value same function that can be done via the right dial when domestic hot water mode is enabled U05 When On Off room thermostat and outdoor sensor are both connected this parameter value is the virtu...

Page 10: ...Do not let your room become too hot Decreasing the room temperature during the day saves energy Have your combi boiler s maintenance performed at least annually Provide your building with sufficient...

Page 11: ...E1 73 Internal PCB error Perform reset if needed If problem repeats contact your service agent H9 01 Outside sensor fault Boiler continues operation but outside sensor is defective Contact your servi...

Page 12: ...who commissioned the boiler as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference GAS BOILER SYSTEM COMMISSIONI...

Page 13: ...It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed Service Provider SERVICE RECORD SERVICE 01 AND Where Possible AND Signat...