2 Safety instructions

Installation manual

4

D035A1/4AA + D035A4AA

Wall-mounted condensing boiler

3P469346-5E – 2017.06

Pn (80/60)
Pn (50/30)
Qn
D (

Δ

T=30 K)

PMS

PMW

Nox 

kW
kW
kW
l/min

bar
MPa
bar
MPa

/

/

XXXX-XX

PIN: 

a

b

c

d

e

f

g
h

i

j

k

l

m

n

o

p

q

r

s

t

u

v

a

Product number

b

Electrical supply

c

Maximum electrical power consumption

d

Degree of protection

e

Nominal heat output range @ 80/60

f

Nominal heat output range @ 50/30

g

Nominal heat input range

h

Hot water amount @ DT=30

i

NOx class

j

Maximum central heating pressure (bar)

k

Maximum central heating pressure (MPa)

l

Maximum domestic hot water pressure (bar)

m

Maximum domestic hot water pressure (MPa)

n

Country of destination(s)

o

Country of origin

p

Serial number

q

Appliance type

r

Efficiency class

s

Gas category

t

Gas type and supply pressure

u

Product type

v

PIN number

1.3

Symbols on the package

This is a fragile piece of equipment: Please provide a dry
storage space for the unit.

This is a fragile piece of equipment: Please be very careful
not to drop.

Store the unit in a flat position as indicated on the box.

No more than five boxes should be stacked on top of each
other.

2

Safety instructions

These  instructions  are  exclusively  designed  for  qualified  competent
persons.

▪ Work  on  gas  units  must  only  be  carried  out  by  a  qualified  gas

fitter.

▪ Work  on  electrical  equipment  must  only  be  carried  out  by  a

qualified electrician.

▪ The  system  must  be  commissioned  by  a  qualified  competent

person.

WARNING

A  qualified  person  shall  explain  the  operating  principles
and the use of the unit to the user. The user is not allowed
to  perform  any  modifications,  maintenance  or  repairs  on
the  unit,  unless  otherwise  stated,  or  have  the  such
performed  by  unauthorised  third  parties.  Otherwise,  the
unit warranty becomes void.

DANGER

Isolate the boiler from the power mains before working on
it.

WARNING

Unit  installation,  commissioning,  repair,  configuration  and
service must be performed by qualified competent persons
in  accordance  with  local  standards  and  regulations.
Incorrect installation of this unit may harm the user and his/
her  surroundings.  The  manufacturer  is  not  responsible  for
any malfunctions and/or damage that may occur this way.

DANGER

Flammable  fluids  and  materials  must  be  stored  at  least
1 metre away from the boiler.

WARNING

To  ensure  faultless  operation,  long  term  availability  of  all
functions  and  long  working  life  of  the  boiler  only  use
original spares.

3

About the unit

This  Daikin  unit  is  a  wall-mounted  gas-fired  condensing  boiler  that
can  supply  heat  to  central  heating  systems,  as  well  as  supply
domestic hot water. Depending on settings, it is possible to use the
unit  solely  for  hot  water  or  solely  for  central  heating.  Hot  water
supply  type  can  be  instantaneous  or  by  means  of  a  hot  water
storage  tank.  The  type  of  the  boiler  can  be  recognised  from  the
model name written on the identification label. See table below:

Model

Type

Domestic hot water

supply

Filling loop

D2CND028A1AA D2CND028

Instantaneous

Internal

D2CND028A4AA D2CND028

Instantaneous

External

D2CND035A1AA D2CND035

Instantaneous

Internal

D2CND035A4AA D2CND035

Instantaneous

External

D2TND028A4AA

D2TND028

Storage tank

External

D2TND035A4AA

D2TND035

Storage tank

External

A control unit, which contains a user interface, controls the ignition,
safety systems, and other actuators. User interaction is provided via
that  user  interface,  which  is  composed  of  an  LCD  screen,  push
buttons, and two dials, and which is located on the front cover of the
unit.

3.1

Safety systems

The unit is equipped with several safety systems, to protect it against
dangerous conditions:

Flue  safety  system

:  This  is  controlled  by  the  flue  gas  temperature

sensor  located  on  the  flue  outlet  part  of  the  boiler.  It  is  activated
when the flue gas temperature exceeds safety limits.

Overheating safety system

: This is controlled by the safety limiting

thermostat.  It  is  located  on  the  main  heat  exchanger  and  stops  the
unit  when  the  flow  temperature  reaches  100°C,  to  avoid  boiling  of
the water, which may damage the unit.

Summary of Contents for D2TND028A4AA

Page 1: ...Installation manual Wall mounted condensing boiler English Installation manual Wall mounted condensing boiler D2CND028A1AA D2CND028A4AA D2CND035A1AA D2CND035A4AA D2TND028A4AA D2TND035A4AA...

Page 2: ...tatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja lietoti atbilsto i ra ot ja nor d jumie...

Page 3: ...must be appropriately disposed of in accordance with local and national regulations The components are easy to separate and the plastics are marked This allows the various components to be sorted for...

Page 4: ...ce must be performed by qualified competent persons in accordance with local standards and regulations Incorrect installation of this unit may harm the user and his her surroundings The manufacturer i...

Page 5: ...allation from frost damages It is controlled by the flow temperature sensor which is located at the outlet of the main heat exchanger This protection activates the boiler pump when the water temperatu...

Page 6: ...he unit Installation manual 6 D2CND028 035A1 4AA D2TND028 035A4AA Wall mounted condensing boiler 3P469346 5E 2017 06 Bottom view of models D2TND028A4AA and D2TND035A4AA 90 30 100 103 30 125 7 72 132 1...

Page 7: ...s Silencer t Automatic air vent pump u Water pressure sensor v By pass w Boiler pump x Domestic hot water flow sensor y Domestic hot water flow limiter z Internal filling valve included in model D2CN...

Page 8: ...19 0 59 3 32 0 59 4 19 LPG G31 Consumption min max m h 0 2 1 09 0 2 1 38 0 2 1 09 0 2 1 38 Combustion products mass flow rate min max G20 g s 2 2 12 35 2 2 15 47 2 2 12 35 2 2 15 47 Combustion produc...

Page 9: ...oilers 37 C and for other heaters 50 C return temperature at heater inlet 4 Installation 4 1 To open the unit WARNING Only qualified competent persons are allowed to open the unit Certain actions expl...

Page 10: ...o the current I E E Wiring Regulations local Building Regulations or any other local regulations currently in service The intake air must not include chemicals that may cause corrosion toxic gas forma...

Page 11: ...13 m 1 5 bar h h System water height m p System charge pressure bar According to the graph below there is no need to install an additional expansion vessel for the systems with a water volume in the...

Page 12: ...1 Piping connections Piping connections of models D2CND028A1AA D2CND028A4AA D2CND035A1AA and D2CND035A4AA Below find the piping connections of the unit A B D E H C F G A Central heating return connec...

Page 13: ...ious damages in installation or boiler or cause discomfort of the user The manufacturer is not responsible for any damage that may occur this way The installation of the boiler should be in compliance...

Page 14: ...or fire A main switch or other means for disconnection having a contact separation in all poles providing full disconnection under overvoltage category III shall be installed in the fixed wiring Be s...

Page 15: ...9346 5E 2017 06 PG9 PG7 PG7 PG9 Holes on the bottom sheet that are reserved for cable glands are covered with insulation material The insulation material must be bored if glands are to be used Note Un...

Page 16: ...Wall mounted condensing boiler 3P469346 5E 2017 06 4 8 6 Wiring diagram DANGER RISK OF ELECTROCUTION Disconnect the power supply for more than 10 minutes before servicing Models D2CND028A1AA D2CND028A...

Page 17: ...ip Card Ext2 X10 Personal computer production interface Ext3 X1M Opentherm room thermostat Ext4 X2M External power output 230 V AC Ext5 X2M Reserved not in use X1M X4 X11 X12 Low voltage terminal stri...

Page 18: ...lations The boiler must be installed so that the terminal is exposed to external air Position of the terminal must allow the free passage of air across it at all times Pluming may occur at the flue te...

Page 19: ...length L is measured from lip of the elbow to end of the flue terminal L a L Flue duct length a Distance of outer lip of terminal to outer wall a 50 mm Note Flue ducts are inserted 45 mm into elbows...

Page 20: ...Elbow 60 100 90 Optional e 90 elbow 60 100 f 45 elbow 60 100 g Tee 60 100 with measurement point h 30 elbow 60 100 i Extension 60 100 L 500 1000 mm Maximum allowable length of the ue duct up to commo...

Page 21: ...mm 1 0 m Equivalent length of options 90 elbow 80 mm 2 0 m Subtract equivalent length value of bends from the allowable flue length value Note The air intake length is 3 metres In case of longer air...

Page 22: ...cular and rough 140 18 2 53 5 Allowable flue length for C93x DN 80 Flex circular and rough 130 11 6 34 1 DN 80 Flex circular and rough 120 4 4 13 0 DN 80 Flex square and rough 140 23 8 69 9 DN 80 Flex...

Page 23: ...100 EKFGP4661 45 elbow 80 125 EKFGP4811 30 elbow 60 100 EKFGP4664 30 elbow 80 125 EKFGP4814 Extension duct 60 100 500 mm EKFGP4651 1000 mm EKFGP4652 Extension duct 80 125 500 mm EKFGP4801 1000 mm EKF...

Page 24: ...disconnector or a double check valve according to local regulations After all system connections are performed with care perform the following steps 1 Connect the appliance to the main power supply Du...

Page 25: ...ount the front cover connect the unit to the main power supply 4 10 2 To modify settings for gas conversion 1 Enter the menu section from the user interface Select service settings by using the left d...

Page 26: ...nutes even if there is demand First 0 2 minutes The electronic gas adaptive system calibrates itself Next 8 10 minutes The boiler performs the low water temperature function You can skip this function...

Page 27: ...plain the function of the boiler error mode Emphasise that if an error is indicated refer to Error codes in the operation manual Inform the user about frost protection function and advise never to cut...

Page 28: ...MA S STEMLER SAN T C A K kbakkalk y Mah Kay da Cad No 1 Kat 21 22 34750 Ata ehir STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr 3P469346 5E 2017 06...