background image

12

www.daikinac.com

SS-DAX

SS-DAX

www.daikinac.com

PB

Our continuing commitment to quality products may mean a change in specifications without notice.

 

©2023 

  •  Houston, Texas  •  Printed in the USA. 

Notes

Summary of Contents for DAX Commercial

Page 1: ...speed direct drive motors Copper tube aluminum fin coils AHRI Certified ETL Listed Complete warranty details available from your local dealer or at www daikincomfort com DAX Commercial Contents Nomen...

Page 2: ...kin Major Minor Revisions Not used for inventory management Product Type Electrical A Single Piece Air Handler 3 208 230 V Three Phase 60 Hz 4 460 V Three Phase 60 Hz Refrigerant Unit Applicationon 4...

Page 3: ...0 60 3 460 60 3 208 240 60 3 460 60 3 FLA LRA 6 9 47 7 2 3 23 9 6 9 47 7 2 3 23 9 Blower Controls Wheel Dia Width Qty 11 x 10 2 11 x 10 2 11 x 10 2 11 x 10 2 Nominal Airflow Ft Min 3 000 3 000 4 000 4...

Page 4: ...24 0 4 2805 810 0 23 0 5 2594 869 0 25 0 5 2690 844 0 24 0 6 2453 909 0 26 0 6 2553 882 0 25 0 7 2310 947 0 27 0 7 2414 919 0 26 0 8 2189 981 0 28 0 8 2295 953 0 27 T4 0 1 3456 794 0 29 T4 0 1 3509 77...

Page 5: ...85 850 0 47 T3 0 1 3869 838 0 46 0 2 3688 875 0 48 0 2 3757 867 0 48 0 3 3590 904 0 50 0 3 3662 896 0 49 0 4 3500 931 0 51 0 4 3559 924 0 51 0 5 3407 958 0 53 0 5 3470 951 0 53 0 6 3310 987 0 54 0 6 3...

Page 6: ...12 17 17 2900 16 21 21 3900 12 16 16 3000 16 21 21 4000 12 16 16 3100 16 20 20 4100 12 15 15 3200 15 20 20 4200 11 15 15 30 2800 24 32 32 30 3800 19 25 25 2900 23 31 31 3900 18 24 24 3000 23 30 30 40...

Page 7: ...ne N A 460 3 60 N A N A 5 2 15 AHKD15 4A 15 480 3 60 1 55 28 3 30 AHKD20 4A 20 480 3 60 2 57 35 8 40 AHKD30 4A 30 480 3 60 2 58 50 9 60 Minimum Circuit Ampacity Maximum Overcurrent Protection Notes Th...

Page 8: ...lyandReturnDuctDimensions Dimensional Data for Electric Heater Kits 15 20 30 kW Heater Kits Supply opening is 13 x 40 13 7 8 40 1 8 13 40 14 11 3 1 8 24 13 1 4 10 3 8 13 1 8 40 1 4 38 1 4 48 1 8 7 60...

Page 9: ...PLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL AT LEAST 105 C USE COPPER CONDUCTORS ONLY USE N E C CLASS 2 WIRE FOR ALL LOW VOLTAGE FIELD CONNECTIONS FAN ONLY AND LOW COOLING MODE...

Page 10: ...LD CONNECTIONS THIS DIAGRAM IS TO BE INCLUDED IN INSTALLATION INSTRUCTIONS A SEPARATE WIRING DIAGRAM IS CONTAINED INSIDE THE CONTROL BOX FOR UNIT FACTORY WIRING THIS IS A SYSTEM WIRING DIAGRAM SHOWING...

Page 11: ...c com 11 Accessoires AHKD Model DAX090 DAX120 Electric Heat Kits AHKD15 3A X X AHKD20 3A X X AHKD30 3A X X AHKD15 4A X X AHKD20 4A X X AHKD30 4A X X Freeze Protection Kit FSK04A X X TX3N4 TXV KIt X X...

Page 12: ...12 www daikinac com SS DAX Our continuing commitment to quality products may mean a change in specifications without notice 2023 Houston Texas Printed in the USA Notes...

Reviews: