DC96SE Airflow Data
CFM & TEMPERATURE RISE VS. EXTERNAL STATIC PRESSURE
Model
DIP SWITCH
-
ES S2-1 , S2-2
External Static Pressure, (Inches Water Column)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
CFM
CFM
DC96SE
0403B
OFF OFF
629
N/A
566
N/A
509
N/A
450
N/A
388
N/A
327
269
228
ON OFF*
949
37
899
40
853
42
809
44
786
45
742
697
652
ON ON
733
49
672
53
613
N/A
563
N/A
512
N/A
454
404
349
OFF ON**
1126
N/A
1086
N/A
1044
N/A
1006
N/A
968
N/A
925
885
849
DC96SE
0603B
OFF OFF
754
N/A
684
N/A
615
N/A
542
N/A
471
N/A
411
343
276
ON OFF*
1332
40
1291
41
1252
43
1218
44
1173
45
1134
1088
1049
ON ON
972
55
922
58
864
62
811
N/A
767
N/A
718
651
597
OFF ON
1155
46
1105
48
1056
51
1006
53
958
56
908
857
808
DC96SE
0804C
OFF OFF
760
N/A
686
N/A
613
N/A
542
N/A
459
N/A
376
310
266
ON OFF*
1390
51
1342
53
1292
55
1254
57
1201
59
1157
1112
1072
ON ON
1397
51
1361
52
1318
54
1266
56
1224
58
1181
1139
1095
OFF ON**
1581
N/A
1537
N/A
1492
N/A
1452
N/A
1413
N/A
1387
1347
1305
DC96SE
1005C
OFF OFF
1211
N/A
1129
N/A
1045
N/A
964
N/A
890
N/A
812
764
702
ON OFF*
1650
54
1592
56
1530
58
1478
60
1428
62
1389
1327
1270
ON ON
1457
61
1394
64
1338
66
1294
69
1236
N/A
1171
1110
1048
OFF ON**
1860
N/A
1810
N/A
1755
N/A
1702
N/A
1656
N/A
1611
1553
1511
DC96SE
1205D
OFF OFF
1296
N/A
1190
N/A
1076
N/A
960
N/A
839
N/A
760
653
559
ON OFF*
1917
56
1843
58
1759
61
1686
63
1600
67
1513
1420
1348
ON ON
1611
66
1521
70
1433
74
1347
N/A
1246
N/A
1145
1044
953
OFF ON**
2011
N/A
1936
N/A
1858
N/A
1779
N/A
1692
N/A
1610
1531
1442
¹ at 0.5" ESP
Notes
•
CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires
two return filters, this chart assumes both filters are installed.
•
All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.
•
For most jobs, about 400 CFM per ton when cooling is desirable.
•
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
•
This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate.
The shaded area indicates ranges in excess of maximum static pressure allowed when heating.
•
The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the
same temperature rise at a particular CFM, while ESP at the CFM will be lower.
Minimum Filter Sizes
DC96SE
0403BNA
DC96SE
0603BNA
DC96SE
0804CNA
DC96SE
1005CNA
DC96SE
1205DNA
Filter Size (in²) (Qty)
(2) 10 x 20 or (1) 16 x 25 (top return)
(1) 14 x 20 (bottom) or (1) 20 x 25 (top return)
Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located.