2
www.daikincomfort.com
SS-DM96SE
SS-DM96SE
www.daikincomfort.com
3
DM96SE
0403AN
DM96SE
0603BN
DM96SE
0803BN
DM96SE
0804CN
DM96SE
0805CN
DM96SE
1005CN
DM96SE
1205DN
Heating Data
High Fire Input¹
40,000
60,000
80,000
80,000
80,000
100,000
120,000
High Fire Output¹
38,440
57,660
76,880
76,880
76,880
96,100
115,320
AFUE²
96
96
96
96
96
96
96
Temperature Rise Range (°F)
25-55
35-65
35-65
25-55
25-55
30-60
35-65
Vent Diameter³
2" - 3"
2" - 3"
2" - 3"
2" - 3"
2" - 3"
2" - 3"
3"
No. of Burners
2
3
4
4
4
5
6
Circulator Blower
Available AC @ 0.5" ESP
1.5 - 3
1.5 - 3
1.5 - 3
1.5 - 4
3 - 5
3 - 5
3 - 5
Size (D x W)
11" x 6"
11" x 8"
11" x 8"
11" x 10"
11" x 10"
11" x 10"
11" x 11"
Horsepower @ 1075 RPM
½
½
½
¾
1
1
1
No. of Speeds
5
5
5
5
5
5
5
Electrical Data
Min. Circuit Ampacity
⁴
10.3
10.3
10.3
14.1
16.93
16.93
16.93
Max. Overcurrent Device (amps)⁵
15
15
15
15
20
20
20
Shipping Weight (lbs)
113
116
118
141
142
144
156
ENERGY STAR®
Certified
1 Natural Gas BTU/h; for altitudes 0-4500' above sea level, reduce input rating by 4% for each 1000' above 4500' altitude.
² DOE AFUE based upon Isolated Combustion System (ICS)
³ Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1
(in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada).
⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
Gas Service Connection ½" FPT
•
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
•
For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
DM96SE