DM96SE Airflow Data
CFM & TEMPERATURE RISE VS. EXTERNAL STATIC PRESSURE
Model
DIP SWITCHES
S2-1 , S2-2
External Static Pressure, (Inches Water Column)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
CFM
CFM
DM96SE
0403A
OFF OFF
715
50
666
53
609
N/A
558
N/A
500
N/A
438
386
333
ON OFF*
1110
32
1081
33
1042
34
1003
35
965
37
933
893
856
ON ON
913
39
871
41
833
43
807
44
765
46
722
675
629
OFF ON**
1191
N/A
1168
N/A
1135
N/A
1112
N/A
1081
N/A
1055
1024
998
DM96SE
0603B
OFF OFF
785
N/A
717
N/A
648
N/A
587
N/A
520
N/A
457
400
327
ON OFF*
1240
43
1194
45
1153
46
1104
48
1069
50
1019
971
929
ON ON
972
55
922
58
864
62
811
N/A
767
N/A
718
651
597
OFF ON**
1155
N/A
1105
N/A
1056
N/A
1006
N/A
958
N/A
908
857
808
DM96SE
0803B
OFF OFF
747
N/A
676
N/A
602
N/A
529
N/A
453
N/A
386
329
281
ON OFF*
1206
57
1157
59
1111
61
1059
62
1009
65
966
913
863
ON ON
985
N/A
931
N/A
875
N/A
823
N/A
782
N/A
723
673
606
OFF ON**
1149
N/A
1095
N/A
1051
N/A
1003
N/A
951
N/A
900
845
812
DM96SE
0804C
OFF OFF
1010
N/A
935
N/A
861
N/A
785
N/A
721
N/A
631
553
483
ON OFF*
1621
44
1570
45
1521
47
1467
48
1414
50
1378
1327
1274
ON ON
1439
49
1400
51
1347
53
1291
55
1234
N/A
1182
1125
1065
OFF ON**
1826
N/A
1775
N/A
1726
N/A
1684
N/A
1634
N/A
1588
1538
1492
DM96SE
0805C
OFF OFF
1012
N/A
937
N/A
861
N/A
801
N/A
722
N/A
630
552
485
ON OFF*
1836
39
1787
40
1746
41
1699
42
1653
43
1607
1561
1514
ON ON
1431
50
1389
51
1335
53
1283
55
1226
N/A
1176
1117
1055
OFF ON**
1836
39
1787
40
1746
41
1699
42
1653
43
1607
1561
1514
DM96SE
1005C
OFF OFF
1012
N/A
940
N/A
863
N/A
800
N/A
715
N/A
627
561
496
ON OFF*
1826
49
1783
50
1730
51
1685
53
1642
54
1596
1548
1504
ON ON
1465
N/A
1402
N/A
1360
N/A
1306
N/A
1250
N/A
1197
1138
1073
OFF ON
1602
55
1556
57
1510
59
1460
N/A
1411
N/A
1372
1315
1261
DM96SE
1205D
OFF OFF
1121
N/A
1018
N/A
933
N/A
839
N/A
762
N/A
671
592
519
ON OFF*
1969
54
1913
56
1862
57
1807
59
1756
61
1705
1647
1599
ON ON
1688
63
1626
N/A
1564
N/A
1500
N/A
1448
N/A
1393
1334
1267
OFF ON
1865
57
1812
59
1755
61
1692
63
1638
65
1587
1527
1476
¹ at 0.5" ESP
Notes
•
CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires
two return filters, this chart assumes both filters are installed.
•
All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.
•
For most jobs, about 400 CFM per ton when cooling is desirable.
•
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
•
This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate.
The shaded area indicates ranges in excess of maximum static pressure allowed when heating.
•
The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately
the same temperature rise at a particular CFM, while ESP at the CFM will be lower.
Minimum Filter Sizes
DM96SE
0403ANA
DM96SE
0603BNA
DM96SE
0803BNA
DM96SE
0804CNA
DM96SE
0805CNA
DM96SE
1005CNA
DM96SE
1205DNA
Filter Size (in²) (Qty)
(1) 16xX 25 (side or bottom)
14 X 25 (bottom)
(1) 16xX 25
(side or bottom)
(1) 20 x 25 (bottom)
or (2) 16 x 25 (side)
Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located.