WIRING DIAGRAMS
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HI
G
H V
O
LT
A
G
E
!
DI
S
CO
NNE
CT
AL
L
PO
W
E
R BE
FO
RE
S
ERV
ICI
NG
O
R I
NS
TA
LL
IN
G
T
HI
S
U
N
IT
. M
U
LT
IPL
E PO
W
ER
SO
U
R
C
ES M
AY B
E P
R
ESEN
T.
F
A
IL
U
R
E
TO
DO
S
O
M
AY
CAUS
E P
RO
P
ERT
Y DAM
AG
E,
P
ERS
O
NAL
INJ
UR
Y O
R DE
AT
H
.
28
DCC072* 203-230, 460, 575 / 3 / 60 2 SPEED
PU
WH
RD
B
R2
6
5
2
4
3
1
YL
BL
BL
RD
RD
YL
PU
PU
RD
BL
3
2
1
4
BL
BR
7
6
5
WH
8
PU
9
RD
WH
YL
PU
PU
RD
BL
BR
PU
YL
PU
WH
BR
YL
WH
GR
GR
YL
PU
GR
RD
BL
YL
PU
9
8
PU
PU
5
6
7
YL
4
1
2
3
YL
RD
9
WH
8
GR
5
6
7
BL
YL
4
PU
PU
1
2
3
YL
ECON S
HR
T
P
LM
ECON PLF
RD
RD
BL
BL
PU
PU
BR
YL
WH
GR
BK
BK
GR
6
5
2
4
3
1
BR
RD
BK
BR
BK
BR
BL
RD
RD
PU
RD
BL
BL
YL
PU
RD
PU
BL
RD
BL
RD
BR
BK
BL
YL
PU
PU
YL
BL
RD
BL
NC
COM
NO
GR
SPEED-UP
G
X
FMR-R
X
FMR-C
R
RD
PU
RD
GR
GR
GR
BL
YL
BL
BK
BL
BR
YL
BL
6
2
PU
BL
BL
PU
RD
GR
RD
RD
BK
RD
S1
S2
R
4
WH
BR
GR
WH
PU
YL
O
G
W
1
Y2
W
2
Y1
3
5
BL
BK
RD
BK
GR
BL
SUPP
LY (
LINE)
V
O
LT
A
G
E
24 VAC
GR
RD
GR
C
BL
BL
BL
BL
BL
BL
3
FIELD C
ON
T
R
OL
WIRIN
G
C
LASS
2
FIELD CO
NT
RO
L
WIRIN
G
C
LASS 2
1.
REPLAC
EM
ENT
W
IRE
M
U
ST
BE
SAME
SIZE
AN
D
T
Y
PE
OF
INS
U
LAT
ION AS ORIGIN
AL (U
SE COPPE
R
C
O
N
D
U
CTORS ON
LY).
2
IF OPT
IONAL ECON
O
MIZE
R IS INST
ALLED, REM
OVE ECON S
H
RT
PLM
AN
D
C
O
N
N
ECT
ECON
PLM
TO
ECON
PLF.
3
T
B3 L
O
W
VOL
T
AGE
T
ER
MI
N
AL B
LOCK.
4
T
ER
MI
N
ALS FOR (
+)24VA
C
-P
W
R
(R
D, BR W
IRE
),AN
D
6
T
ER
MI
N
ALS FOR (
-) 24VA
C
-C
O
M (BL W
IRE
).
4
CON
N
ECTI
ON
S SHOW
N AR
E FOR 1-STAGE HEAT
OPER
AT
ION.
W
H
EN 2
-STA
GE OPERAT
ION IS REQIR
E
D
R
EM
OVE JU
M
PER
W
IRE
CON
N
ECTING
W
2
T
O
W
1
ON
T
B1.
5
IF OPT
IONAL SMOKE D
E
T
ECTOR(S
) AR
E
INST
ALLED,
REM
OVE
JU
M
PER
W
IRE
C
O
N
N
ECTING
S1
T
O
S2
ON
T
B1.
W
IR
E
C
O
N
N
E
C
TI
O
N
S
F
R
OM
A
C
C
E
SS
O
R
Y
K
IT
:
CO
N
N
ECT
RD
W
IRE
T
O
T
B1-S1.
CO
N
N
ECT
BR
W
IRE
T
O T
B1-S2.
CO
N
N
ECT
B
L T
O T
B3,(24
COM
).
6
EB
TDR:
FAN
EN
ER
GIZED
7
SEC
AF
T
ER
24V
APPL
IED
T
O
"G".
FAN D
E-E
N
ER
GIZED 65 SEC AF
T
ER 24V
R
E
M
OVED
FR
O
M
"
G"
.
IF
SPEED
-U
P
T
ER
MI
N
AL
IS
SHORTED
T
O
GRO
U
N
D
ALL
DELAY
S
ARE
RE
D
U
C
E
D
TO
~5
SEC.
CONTROLS DIAGRAM
DCC072
2 SPEED EM
2 STAGE COMP
PU
YL
WH
GR
BL
BL
2
3
2
1
4
7
6
5
8
9
YL
YL
PU
PU
RD
OR
GR
BL
RD
BK
BK
EC
ON ACT
S-BUS
S-BUS
1
2
3
4
24V-C
OM
24
V-PWR
G
RD
BR
WH WH
WH
ENT
H
MAS
PK
PK
BL
GR
OR
RD
PU
PU
YL
YL
MAS
-t°
OAT
S-BUS
1
2
3 4
5
6
1
2
3 4
5
6
1
2
C
R
1
2
1
4
2
3
Y1-
O
Y2-
O
Y1-I
4
1
2
3
S-BUS
Y2-I
OAT
OPT
ION
AL EC
ON
OMIZER
E
XH
1
E-G
ND
AUX2-I
O
CC
AUX1-O
E
C
O
N
P
LM
AC
T
24V
AC
T
COM
IAQ
24V
IAQ C
OM
IAQ 2-10
M
AT
M
AT
PLF 1
TB1
T
B3
T
B1
T
R1
T
B3
EBT
D
R
BR1
CC
BC1
B
C2
CS
BL
7
7
PLF1 CON
N
ECTOR FO
R OPT
IONAL ELECTRIC H
EA
T
.
SEE
ELEC
TRIC H
EAT
SC
H
EM
AT
IC FO
R
W
IRIN
G CO
N
N
ECTI
ON
S.
YL
PK
AUX B
AUX A
8
18
7
Y
Y
R
B
SENSOR 2
Y
Y
R
B
SEN2
PK
OPT
ION
AL
SMOKE DET
EC
T
OR
Y
Y
R
B
24V
AC/DC
SENSOR 1
9
10
Y
Y
R
B
16 6
17
SEN1
RD
BR
BL
5
BL
BL/
P
K
YL
BL/
P
K
HPS
LPS
YL/
PK
YL/
PK
YL
YL
GR
BR
WH
0140L
049
68
-A