background image

12

www.daikincomfort.com

SS-

DM96SE

SS-

DM96SE

www.daikincomfort.com

13

COOLING AIRFLOW DATA

Model

DIP SWITCHES 

S1-1 , S1-2 , S1-3

External Static Pressure, (Inches Water Column)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

DC96SE 

0403B

OFF OFF OFF

629

566

509

450

388

327

269

228

195

153

OFF ON ON

629

566

509

450

388

327

269

228

195

153

ON OFF ON

629

566

509

450

388

327

269

228

195

153

ON ON ON

629

566

509

450

388

327

269

228

195

153

ON OFF OFF

949

899

853

809

786

742

697

652

609

575

ON ON OFF

733

672

613

563

512

454

404

349

306

261

OFF ON OFF

1126

1086

1044

1006

968

925

885

849

827

792

OFF OFF ON*

1359

1321

1284

1251

1218

1181

1147

1114

1080

1045

DC96SE 

0603B

OFF OFF OFF

754

684

615

542

471

411

343

276

214

N/A

OFF ON ON

754

684

615

542

471

411

343

276

214

N/A

ON OFF ON

754

684

615

542

471

411

343

276

214

N/A

ON ON ON

754

684

615

542

471

411

343

276

214

N/A

ON OFF OFF

1332

1291

1252

1218

1173

1134

1088

1049

1013

N/A

ON ON OFF

972

922

864

811

767

718

651

597

556

511

OFF ON OFF

1155

1105

1056

1006

958

908

857

808

772

723

OFF OFF ON*

1384

1338

1300

1257

1215

1189

1169

1125

1080

1040

DC96SE 

0804C

OFF OFF OFF

760

686

613

542

459

376

310

266

224

190

OFF ON ON

760

686

613

542

459

376

310

266

224

190

ON OFF ON

760

686

613

542

459

376

310

266

224

190

ON ON ON

760

686

613

542

459

376

310

266

224

190

ON OFF OFF

1390

1342

1292

1254

1201

1157

1112

1072

1022

985

ON ON OFF

1397

1361

1318

1266

1224

1181

1139

1095

1050

1003

OFF ON OFF

1581

1537

1492

1452

1413

1387

1347

1305

1267

1225

OFF OFF ON*

1800

1758

1716

1678

1636

1601

1565

1529

1491

1457

DC96SE 

1005C

OFF OFF OFF

1211

1129

1045

964

890

812

764

702

639

583

OFF ON ON

1211

1129

1045

964

890

812

764

702

639

583

ON OFF ON

1211

1129

1045

964

890

812

764

702

639

583

ON ON ON

1211

1129

1045

964

890

812

764

702

639

583

ON OFF OFF

1650

1592

1530

1478

1428

1389

1327

1270

1213

1159

ON ON OFF

1457

1394

1338

1294

1236

1171

1110

1048

986

919

OFF ON OFF

1860

1810

1755

1702

1656

1611

1553

1511

1454

1405

OFF OFF ON*

2230

2176

2125

2086

2038

1999

1958

1917

1880

1829

DC96SE 

1205D

OFF OFF OFF

1296

1190

1076

960

839

760

653

559

452

351

OFF ON ON

1296

1190

1076

960

839

760

653

559

452

351

ON OFF ON

1296

1190

1076

960

839

760

653

559

452

351

ON ON ON

1296

1190

1076

960

839

760

653

559

452

351

ON OFF OFF

1917

1843

1759

1686

1600

1513

1420

1348

1258

1173

ON ON OFF

1611

1521

1433

1347

1246

1145

1044

953

876

790

OFF ON OFF

2011

1936

1858

1779

1692

1610

1531

1442

1365

1266

OFF OFF ON*

2317

2257

2196

2122

2061

1990

1914

1762

1523

1232

Summary of Contents for DM96SE

Page 1: ...d Features Cabinet Features Heavy duty stainless steel tubular heat exchanger Stainless steel secondary heat exchanger Single stage gas valve Durable Silicon Nitride igniter Multi speed blower motor S...

Page 2: ...Downflow Horizontal A Initial Release B 1st Revision AFUE 97 97 98 AFUE 92 92 AFUE NOx 96 96 AFUE N Low Nox 40ng J Gas Valve Cabinet Width M Modulating A 14 V Two Stage S Single Stage B 17 C 21 Motor...

Page 3: ...h 1000 above 4500 altitude DOE AFUE based upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Ga...

Page 4: ...rtified NO NO NO NO NO Natural Gas BTU h for altitudes 0 4500 above sea level reduce input rating by 4 for each 1000 above 4500 altitude DOE AFUE based upon Isolated Combustion System ICS Vent and com...

Page 5: ...0 19 20 5 9 19 34 19 B C 23 2 1 2 2 6 5 9 19 23 24 31 A 21 2 14 23 1 1 287 8 2 1 2 2 2 6 1 26 23 Folded Flanges 22 Unfolded Flanges D Unfolded Flanges E Folded Flanges Air Discharge Air Discharge LEFT...

Page 6: ...r Drain Trap Holes Low Voltage Electrical Outlet Air Discharge Air Discharge Folded Flanges B 18 Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0 0 3 NC...

Page 7: ...N A 800 N A 715 N A 627 561 496 ON OFF 1826 49 1783 50 1730 51 1685 53 1642 54 1596 1548 1504 ON ON 1465 N A 1402 N A 1360 N A 1306 N A 1250 N A 1197 1138 1073 OFF ON 1602 55 1556 57 1510 59 1460 N A...

Page 8: ...ON 2215 2171 2137 2098 2060 2022 1986 1948 1908 1869 DM96SE 1005C OFF OFF 1012 940 863 800 715 627 561 496 437 374 ON OFF 1826 1783 1730 1685 1642 1596 1548 1504 1455 1406 OFF ON 1602 1556 1510 1460 1...

Page 9: ...0 935 861 785 721 631 553 483 423 350 ON OFF ON 1010 935 861 785 721 631 553 483 423 350 ON ON ON 1010 935 861 785 721 631 553 483 423 350 ON OFF OFF 1621 1570 1521 1467 1414 1378 1327 1274 1221 1167...

Page 10: ...205D OFF OFF 1296 N A 1190 N A 1076 N A 960 N A 839 N A 760 653 559 ON OFF 1917 56 1843 58 1759 61 1686 63 1600 67 1513 1420 1348 ON ON 1611 66 1521 70 1433 74 1347 N A 1246 N A 1145 1044 953 OFF ON 2...

Page 11: ...OFF ON 2230 2176 2125 2086 2038 1999 1958 1917 1880 1829 DC96SE 1205D OFF OFF 1296 1190 1076 960 839 760 653 559 452 351 ON OFF 1917 1843 1759 1686 1600 1513 1420 1348 1258 1173 ON ON 2011 1936 1858...

Page 12: ...266 224 190 OFF ON ON 760 686 613 542 459 376 310 266 224 190 ON OFF ON 760 686 613 542 459 376 310 266 224 190 ON ON ON 760 686 613 542 459 376 310 266 224 190 ON OFF OFF 1390 1342 1292 1254 1201 11...

Page 13: ...T BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 80...

Page 14: ...OWER PRESSURE SWITCH RD WH BURNER COMPARTMENT BLOWER COMPARTMENT NO YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD OR PK BK WH WH BLOWER INDUCED DRAFT AUXILIARY LIMI...

Page 15: ...ion Kits Notes Indicates available for this model Indicates 9 001 to 11 000 altitude Indicates 7 001 to 9 000 altitude Indicates 7 001 to 11 000 altitude All installations above 7 000 require a pressu...

Page 16: ...16 www daikincomfort com SS DM96SE Our continuing commitment to quality products may mean a change in specifications without notice 2021 Houston Texas Notes...

Reviews: