DM96SE Airflow Data  

CFM & TEMPERATURE RISE VS. EXTERNAL STATIC PRESSURE

Model

DIP SWITCHES 

S2-1 , S2-2

External Static Pressure, (Inches Water Column)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

CFM

CFM

DM96SE 

0403A

OFF OFF

715

50

666

53

609

N/A

558

N/A

500

N/A

438

386

333

ON OFF*

1110

32

1081

33

1042

34

1003

35

965

37

933

893

856

ON ON

913

39

871

41

833

43

807

44

765

46

722

675

629

OFF ON**

1191

N/A

1168

N/A

1135

N/A

1112

N/A

1081

N/A

1055

1024

998

DM96SE 

0603B

OFF OFF

785

N/A

717

N/A

648

N/A

587

N/A

520

N/A

457

400

327

ON OFF*

1240

43

1194

45

1153

46

1104

48

1069

50

1019

971

929

ON ON

972

55

922

58

864

62

811

N/A

767

N/A

718

651

597

OFF ON**

1155

N/A

1105

N/A

1056

N/A

1006

N/A

958

N/A

908

857

808

DM96SE 

0803B

OFF OFF

747

N/A

676

N/A

602

N/A

529

N/A

453

N/A

386

329

281

ON OFF*

1206

57

1157

59

1111

61

1059

62

1009

65

966

913

863

ON ON

985

N/A

931

N/A

875

N/A

823

N/A

782

N/A

723

673

606

OFF ON**

1149

N/A

1095

N/A

1051

N/A

1003

N/A

951

N/A

900

845

812

DM96SE 

0804C

OFF OFF

1010

N/A

935

N/A

861

N/A

785

N/A

721

N/A

631

553

483

ON OFF*

1621

44

1570

45

1521

47

1467

48

1414

50

1378

1327

1274

ON ON

1439

49

1400

51

1347

53

1291

55

1234

N/A

1182

1125

1065

OFF ON**

1826

N/A

1775

N/A

1726

N/A

1684

N/A

1634

N/A

1588

1538

1492

DM96SE 

0805C

OFF OFF

1012

N/A

937

N/A

861

N/A

801

N/A

722

N/A

630

552

485

ON OFF*

1836

39

1787

40

1746

41

1699

42

1653

43

1607

1561

1514

ON ON

1431

50

1389

51

1335

53

1283

55

1226

N/A

1176

1117

1055

OFF ON**

1836

39

1787

40

1746

41

1699

42

1653

43

1607

1561

1514

DM96SE 

1005C

OFF OFF

1012

N/A

940

N/A

863

N/A

800

N/A

715

N/A

627

561

496

ON OFF*

1826

49

1783

50

1730

51

1685

53

1642

54

1596

1548

1504

ON ON

1465

N/A

1402

N/A

1360

N/A

1306

N/A

1250

N/A

1197

1138

1073

OFF ON

1602

55

1556

57

1510

59

1460

N/A

1411

N/A

1372

1315

1261

DM96SE 

1205D

OFF OFF

1121

N/A

1018

N/A

933

N/A

839

N/A

762

N/A

671

592

519

ON OFF*

1969

54

1913

56

1862

57

1807

59

1756

61

1705

1647

1599

ON ON

1688

63

1626

N/A

1564

N/A

1500

N/A

1448

N/A

1393

1334

1267

OFF ON

1865

57

1812

59

1755

61

1692

63

1638

65

1587

1527

1476

¹ at 0.5" ESP

Notes

• 

CFM in chart is without filter(s).  Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires 

 

two return filters, this chart assumes both filters are installed.

• 

All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.

• 

For most jobs, about 400 CFM per ton when cooling is desirable.

• 

INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

• 

This chart is for information only.  For satisfactory operation, external static pressure should not exceed value shown on the rating plate. 

 

The shaded area indicates ranges in excess of maximum static pressure allowed when heating.

• 

The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately 

 

the same temperature rise at a particular CFM, while ESP at the CFM will be lower.

Minimum Filter Sizes

DM96SE 

0403ANA

DM96SE

0603BNA

DM96SE

0803BNA

DM96SE

0804CNA

DM96SE

0805CNA

DM96SE

1005CNA

DM96SE

1205DNA

Filter Size (in²) (Qty)

(1) 16xX 25 (side or bottom)

 

14 X 25 (bottom)

(1) 16xX 25 

 

(side or bottom)

(1) 20 x 25 (bottom) 

 

or (2) 16 x 25 (side)

Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located.

Summary of Contents for DM96SE

Page 1: ...d Features Cabinet Features Heavy duty stainless steel tubular heat exchanger Stainless steel secondary heat exchanger Single stage gas valve Durable Silicon Nitride igniter Multi speed blower motor S...

Page 2: ...Downflow Horizontal A Initial Release B 1st Revision AFUE 97 97 98 AFUE 92 92 AFUE NOx 96 96 AFUE N Low Nox 40ng J Gas Valve Cabinet Width M Modulating A 14 V Two Stage S Single Stage B 17 C 21 Motor...

Page 3: ...h 1000 above 4500 altitude DOE AFUE based upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Ga...

Page 4: ...rtified NO NO NO NO NO Natural Gas BTU h for altitudes 0 4500 above sea level reduce input rating by 4 for each 1000 above 4500 altitude DOE AFUE based upon Isolated Combustion System ICS Vent and com...

Page 5: ...0 19 20 5 9 19 34 19 B C 23 2 1 2 2 6 5 9 19 23 24 31 A 21 2 14 23 1 1 287 8 2 1 2 2 2 6 1 26 23 Folded Flanges 22 Unfolded Flanges D Unfolded Flanges E Folded Flanges Air Discharge Air Discharge LEFT...

Page 6: ...r Drain Trap Holes Low Voltage Electrical Outlet Air Discharge Air Discharge Folded Flanges B 18 Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0 0 3 NC...

Page 7: ...N A 800 N A 715 N A 627 561 496 ON OFF 1826 49 1783 50 1730 51 1685 53 1642 54 1596 1548 1504 ON ON 1465 N A 1402 N A 1360 N A 1306 N A 1250 N A 1197 1138 1073 OFF ON 1602 55 1556 57 1510 59 1460 N A...

Page 8: ...ON 2215 2171 2137 2098 2060 2022 1986 1948 1908 1869 DM96SE 1005C OFF OFF 1012 940 863 800 715 627 561 496 437 374 ON OFF 1826 1783 1730 1685 1642 1596 1548 1504 1455 1406 OFF ON 1602 1556 1510 1460 1...

Page 9: ...0 935 861 785 721 631 553 483 423 350 ON OFF ON 1010 935 861 785 721 631 553 483 423 350 ON ON ON 1010 935 861 785 721 631 553 483 423 350 ON OFF OFF 1621 1570 1521 1467 1414 1378 1327 1274 1221 1167...

Page 10: ...205D OFF OFF 1296 N A 1190 N A 1076 N A 960 N A 839 N A 760 653 559 ON OFF 1917 56 1843 58 1759 61 1686 63 1600 67 1513 1420 1348 ON ON 1611 66 1521 70 1433 74 1347 N A 1246 N A 1145 1044 953 OFF ON 2...

Page 11: ...OFF ON 2230 2176 2125 2086 2038 1999 1958 1917 1880 1829 DC96SE 1205D OFF OFF 1296 1190 1076 960 839 760 653 559 452 351 ON OFF 1917 1843 1759 1686 1600 1513 1420 1348 1258 1173 ON ON 2011 1936 1858...

Page 12: ...266 224 190 OFF ON ON 760 686 613 542 459 376 310 266 224 190 ON OFF ON 760 686 613 542 459 376 310 266 224 190 ON ON ON 760 686 613 542 459 376 310 266 224 190 ON OFF OFF 1390 1342 1292 1254 1201 11...

Page 13: ...T BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 80...

Page 14: ...OWER PRESSURE SWITCH RD WH BURNER COMPARTMENT BLOWER COMPARTMENT NO YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD OR PK BK WH WH BLOWER INDUCED DRAFT AUXILIARY LIMI...

Page 15: ...ion Kits Notes Indicates available for this model Indicates 9 001 to 11 000 altitude Indicates 7 001 to 9 000 altitude Indicates 7 001 to 11 000 altitude All installations above 7 000 require a pressu...

Page 16: ...16 www daikincomfort com SS DM96SE Our continuing commitment to quality products may mean a change in specifications without notice 2021 Houston Texas Notes...

Reviews: