37
and their corresponding taps. Verify CFM by noting the
number displayed on the dual 7-segment LED display.
6. The multi-speed circulator blower also offers several custom
ON/OFF ramping profiles. These profiles may be used to
enhance cooling performance and increase comfort level.
The ramping profiles are selected using DIP switches S4-
1, 2. Refer to the following figure for switch positions
and their corresponding taps. Refer to the following bullet
points for a description of each ramping profile. Verify
CFM by noting the number displayed on the dual 7-segment
LED display.
3
4
A
OFF
OFF
B*
ON
OFF
C
OFF
ON
D
ON
ON
(Indicates factory setting)
Sw itch Bank S4
Heating
Airflow
DIP Sw itch No.
•
Profile A
provides only an OFF delay of one (1) minute
at 100% of the cooling demand airflow
.
OFF
100% CFM
100% CFM
1 min
OFF
Figure 50
•
Profile B
ramps up to full cooling demand airflow by
first stepping up to 50% of the full demand for 30
seconds. The motor then ramps to 100% of the
required airflow. A one (1) minute OFF delay at 100%
of the cooling airflow is provided.
50% CFM
1/2 min
100% CFM
100% CFM
1 min
OFF
OFF
Figure 51
•
Profile C
ramps up to 85% of the full cooling demand
airflow and operates there for approximately 7 1/2
minutes. The motor then steps up to the full demand
airflow. Profile C also has a one (1) minute 100%
OFF delay.
100% CFM
OFF
OFF
Figure 52
NOTE:
To enable adjustments and select -5, 5, -10 or 10% trim,
you must set dip switch S5-2 to ON. If S5-2 is in the OFF position,
you will receive 0% trim.
1
2
A
OFF
OFF
B
ON
OFF
C
OFF
ON
D*
ON
ON
Sw itch Bank: S3
Cooling Speed
Taps
DIP Sw itch No.
(*Indicates factory setting)
3
4
+ 5%*
OFF
OFF
- 5%
ON
OFF
+ 10%
OFF
ON
- 10%
ON
ON
Sw itch Bank: S3
Adjust Taps
DIP Sw itch No.
(*Indicates factory setting)
•
Profile D
ramps up to 50% of the demand for 1/2 minute,
then ramps to 85% of the full cooling demand airflow
and operates there for approximately 7 1/2 minutes.
The motor then steps up to the full demand airflow.
Profile D has a 1/2 minute at 50% airflow OFF delay.
OFF
OFF
Figure 53