PRODUCT IDENTIFICATION
8
MODEL #
MFG #
DESCRIPTION
DCVK-20
(CVENT-2)
DCVK-30
(CVENT-3)
N/A
Concentric Vent Kit
. For use with Daikin Modulating furnace models.
This kit is designed to allow terminations
of a direct vent furnace to be "concentrically" vented through a wall or roof. This kit allows a single penetration to
support terminations for both the vent/flue and the combustion air intake pipe. The DCVK-20 (2") and DCVK-30
(3") kits are certified for models listed above. See specification sheets on future models for use of the vent kit.
DEHUM1
P1227801F
Dehumidistat.
For use with Daikin two-stage variable speed modulating furnace models. Wall mounted, 24 volt
humidity control available as a Dehumidistat used to reduce the airflow in the air conditioning mode when
necessary to lower the humidity in an occupied home to prevent dew build-up associated with high humidity
levels. This control features a moisture-sensitive nylon element and also provides positive ON-OFF settings for
manual operation. The control is a normally closed switch that opens on humidity rise causing the blower to
switch to a lower speed to control the humidity within the structure.
EFR02
N/A
External Filter Rack Kit
. For use with Daikin 97% upflow, variable speed *MVM 34.5" modulating gas furnaces.
This kit is intended to provide a location, external to the furnace casing for installation of a permanent filter. The
rack is mounted over the indoor air blower compartment area of either side panel, and provide filter retention
as well as a location for attaching return air ductwork.
0170K00000S
N/A
Side Wall Only Concentric Vent Kit
. For use with 97% modulating furnace models.
This kit is to be used with
2" - 3" vent systems. The vent kit must terminate outside the structure. This kit is NOT intended for use with
single pipe (indirect vent) installations.
0170K00001S
N/A
Side Wall Only Concentric Vent Kit
. For use with 97% modulating furnace models.
This kit is to be used with
2" vent systems. The vent kit must terminate outside the structure. This kit is NOT intended for use with single
pipe (indirect vent) installation
LPLP03
N/A
LP Gas Low Pressure Kit
. The kit monitors gas line pressure with a pressure switch and will open the circuit
to the gas valve if the LP tank pressure gets low.
LPM-09
N/A
LP Conversion Kit
Converts a 34.5" modulating furnace to operate on L.P. gas. The kit contains an L.P. gas
valve and a set of six L.P. orifices.
RF000142
N/A
Drain Coupling Kit
For use when the drain/vent elbow has been removed in a horizontal left installation. This
kit prevents condensate from getting in the inducer and routes the condensate to a drain.