13
SYSTEM OPERATION
Error History
This menu provides access to the most recent faults. The
recent system error histories are displayed on the screen.
Errors are stored in order from most recent to least recent.
Any consecutively repeated error is stored only once.
NOTE
: It is highly recommended that the error history be
cleared after performing maintenance or servicing the system.
Status
This menu displays information about the systems current
status. This menu can be utilized to confirm correct func
-
tionality of the equipment and for troubleshooting purposes.
Pump Down / Charge Mode
This function can be enabled in this menu.
Set 7-Segment Mode Display To Pump Down
Please follow the following sequence to enter PUMP DOWN
to accumulate the refrigerant to outdoor unit by 7 Segment
Mode. Do not operate COOL ON mode to enter PUMP
DOWN. Before starting the PUMP DOWN operation, change
indoor fan trim, delay and profile back to default and stop
electric heater and gas furnace. Remove if no trim feature.
In this operation, the gas and liquid service valve should be
opened.
1. Set 7-segment display to SCREEN 4 (SETTING MODE
2) Setting No. 8 and change the display from “-01” to
“-00”. System will then automatically start PUMP DOWN
operation. For information on how to set 7-segment dis-
play, see the section SETTING THE MODE DISPLAY in
this manual.
2. 2. Approximately one minute later, the compressor
should start operating. Check the amperage at the com-
pressor wiring to see the compressor operation status.
Unit display error code E11 (System verification Test)
once the PUMP DOWN operations starts.
3. Close liquid service valve approximately two minutes af-
ter compressor has come on.
4. Compressor will come to a stop automatically. Close
the gas service valve immediately after the compressor
stops. After completion of PUMP DOWN, unit shows er-
ror code “
E11
”.
NOTE
: Refrigerant cannot be collected to the outdoor unit
completely if the system is overcharged or if there is a de-
lay in closing the liquid service valve and gas service valve.
Evacuate the left over refrigerant from the system using a
recovery machine.
System Test
The mandatory system verification test is enabled from this
SYSTEM TEST menu, which enables a functional check of the
equipment, in addition to ensuring proper stop valve position.
Cool Settings
This menu allows for the adjustment of several cooling per-
formance variables. Cool Airflow Trim (*1), Cool Airflow Pro
-
files, Cool Airflow ON Delay, Cool Airflow OFF Delay and
Dehumidification Select (some enable option or off ) can be
adjusted in this menu.
*1
1. At Cool and Heat Hi speed trim, DX20VC0601* with
D*96VC0804C, D*97MC0804C and DM80VC0804C
combination trim more than 5% settings are invalid.
Trimmed up CFM makes miss matching error.
2. At Cool Hi speed trim, Other than the above, depending
on the connected indoor unit, there are restrictions on
the positive side Trim setting. If you want to change the
Cool Airflow Trim to positive side, be sure to confirm the
Airflow Trim restrictions in the latest indoor unit instal
-
lation manual. The latest manual can be obtained from
the website
“DAIKIN CITY (Installation Manual/Unitary Split Sys-
tem)” or
“PartnerLink(InfoFinderPlus/Literature)”.
[DAIKIN CITY URL]
https://www.daikincity.com/Library/
[PartnerLink URL]
https://partnerlinkmarketing.goodmanmfg.com/good-
3. At Cool Intermediate and Low speed trim, The Inverter
system uses lower compressor speed and lower indoor
unit CFM to optimize system performance. To obtain 100%
CFM for home circulation, use full Trim setting instead of
Int/ Low speed. This is recommended for applications with
unusually cold return temperatures such as basements.
Cool Airflow Profile (Cool Profile)
•
Pro
fil
e A
provides only an OFF delay of one (1) minute at
100% of the cooling demand air
flo
w.
•
Pro
fil
e B
ramps up to full cooling demand air
flow
by
first
stepping up to 50% of the full demand for 30 seconds.
The motor then ramps to 100% of the required air
fl
ow. A
one (1) minute OFF delay at 100% of the cooling air
fl
ow.