WIRING DIAGRAM
81
INDOOR UNIT FOR EEV APPLICABLE UNIT (DV*PEC)
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
W
IRING C
ODE
0140A00322-A
PO
W
ER/HEATER
CONNECTOR
PL1, P
L2
COMPONENT
CODE
TL
F1U
, F
2U
TR
THERMA
L
LIM
IT
TRANSFORMER FUSE
LINK
FAC
TO
R
Y
W
IRING
HIGH
VOLTAGE
LO
W
V
O
LTAGE
FI
ELD
W
IRING
HIGH
VOLTAGE
LO
W
V
O
LTAGE
EQUI
PM
EN
T
GND
TE
R
M
INAL
PL
U
G
CONN
EC
TI
O
N
JUN
C
TI
ON
RES
IS
TOR
PRO
T. D
EVICE
IN
TE
GR
AT
ED CO
N
TR
OL
IN
TER
N
AL
T
O
FI
EL
D
GND
OVER
C
UR
R
ENT
BL -
BLUE
RD
-
R
ED
YL
-
YE
LL
O
W
OR
- ORA
N
GE
BK
-
BLACK
G
Y -
GREY
BR - BRO
W
N
GR
- GR
EEN
C
O
LO
R C
O
DE
S:
N
O
TE
S:
1.
P
LACE
RED
W
IR
ES
O
N
208
V
T
ER
M
IN
AL
OF
2
-T
RANSFOR
M
ER
(T
R
1/
TR
2)
FOR 20
8
VAC
O
PE
R
ATI
O
N.
S
PEC
IF
IED
R
EP
LA
C
EM
EN
T
PA
R
TS
M
US
T
BE
U
SE
D
W
H
EN
S
ERVICING
.
3.
IF
AN
Y
OF
T
HE
OR
IG
IN
AL
W
IR
ES
A
S
SUP
PL
IED
W
IT
H
T
H
IS
U
N
IT
M
U
ST
B
E
R
EPLACED
, I
T
M
U
ST
B
E
R
EP
LACE
D
W
IT
H
W
IRING
MA
TER
IA
L
H
AV
IN
G
A
U
SE CO
PP
ER CONDU
C
TORS O
N
LY
.
4. U
N
IT
M
U
ST
B
E
PER
M
ANEN
TLY
G
R
OUN
D
ED
AN
D
CON
FOR
M
T
O
N
.E.C
AND
LOCAL CODES.
5.
T
O RECAL
L
THE
LA
ST
6
FAUL
TS
, MOS
T
RECEN
T
TO
L
EA
ST
RECE
N
T,
DEPR
ES
S
FAUL
T RE
C
ALL
BU
TT
ON
FOR MORE
THA
N
2
SE
C
O
NDS
W
HILE
IN
ST
AN
D
BY
(N
O
T
H
ER
M
O
ST
AT
INPU
TS
)
6. RED
S
TA
TUS LED
PROVID
ES N
ET
W
ORK
S
TA
TUS.
GREEN R
X
LED
IN
D
ICA
TE
S N
ET
W
OR
K
TRAF
FIC.
U
SE
L
EAR
N
BU
TT
ON
TO
RE
SE
T
N
ET
W
ORK.
7. D
ISCARD
C
ONNEC
TOR
P
L1
W
HEN
INS
TA
LLING
OP
TI
ONAL
HE
AT
K
IT
.
8.
T
HE
P
O
SI
TI
O
N
O
F S
ELEC
TO
R
S
W
IT
CHES
(D
S1
- DS
6)
IN
D
IC
AT
E
FAC
TO
R
Y
SE
TT
ING.
9. R
EM
O
VE
SHO
R
T RED CIR
C
U
IT
ING
W
IR
E
AND
PU
T
AU
X A
LAR
M
S
W
IT
C
H
W
HE
N
IN
ST
AL
LI
N
G
AUX
ALAR
M
S
W
IT
CH.
DS6
X1A
X3A
X15A
BS2
X5A
X2A
BS1
SEG2
SEG1
DS1
DS2
DS3
DS4
DS5
X7A
X12A
X13A
R
X LED
X8A
IN
D
O
OR
U
NIT PCB
THERMISTOR
(HEAT EXCHANGER 1,2) INTEGRATION TYPE
MPU
C
PU LED
STATUS LED
FA
U
LT RECALL
PRESSURE
SENSOR
EE
V
C
OIL
EE
V
M
INDO
O
R
AIR
C
IRCU
LATIOR
BLWR
EAR
TH
K1R
TB9
K3R
TB6
TB8
K2R
HEATER KIT
OUT
PUT
LEA
R
N
PS
F2U
TB5
TB10
TB4
TB3
TB1
TB7
TB2
F1U
RELAY IN
(A
CC
-O
U
T)
RELAY OUT
(A
CC
-IN
)
AC24V
TH
1
COM
Y2
O
TR
1
W
2
Y1
C
G
W
1
R
2
1
8
9
6
7
3
4
5
1
2
D
EHU
M
BK
RD
RD
BK
RD
BK
G
Y
BL
WH
BR
BL
RD
BK
RD
BL
SHARE DATA
FLASH WRITER
RAM MONITOR
ON OFF
BK
RD
YL
OR
BL
BL
RD
PL1
(SEE NOTE 7)
RD
BK
SE
LECTOR
SW
ITCH
D
S1
- D
S6
GR
GR
GR
O
UN
D LUG
TH
2
TR
2
THERMOSTAT
C
O
N
N
EC
TI
O
N
DISAB
LE
D
BK
G
Y
(SEE NOTE 6)
(SEE NOTE 5)
(SEE NOTE 6)
(SEE NOTE 6)
(SEE NOTE 4)
8
9
6
7
3
4
5
1
2
PL2
24
VAC
TB
5
TB
4
INSTALLING AUX ALARM (ALARM) (SEE NOTE 9)
RD
~~
~~
~ ~
24
VAC
M
O
C
M
O
C
208 VA
C
230 VA
C
208 VA
C
230 VA
C
TR
2
(SEE NOTE 1)
TR
1
(SEE NOTE 1)
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
NOTE:
The
position
of
the
black
square
indicates
the
setting
position
of
the
selector
switches
(DS1-DS6).