Operation manual
19
E(D/B)(H/L)Q011~016BB
Unit and options for air to water heat pump system
4PW67905-1A – 2013.02
6
Installation related setting
00
Installation related setting
01
Installation related setting
02
Not applicable. Do not change the default value.
—
—
—
—
Scheduled storage and reheat domestic water heating
03
Scheduled time storage
1 (ON)
0/1
1
—
04
Scheduled time storage start time
1:00
0:00~23:00
1:00
hour
05
Scheduled time reheat or continuous reheat
0 (OFF)
0/1/2
1
—
06
Scheduled time reheat start time
15:00
0:00~23:00
1:00
hour
07
Domestic hot water reheat set point
45
30~50
1
°C
08
Domestic hot water reheat set point hysteresis
10
2~20
1
°C
7
Installation related setting
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
8
Installation related setting
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
9
Heating and cooling set point ranges
00
Heating set point upper limit
55
37~55
1
°C
01
Heating set point lower limit
25
15~37
1
°C
02
Cooling set point upper limit
22
18~22
1
°C
03
Cooling set point lower limit
5
5~18
1
°C
04
Installation related setting
Automatic set back function
05
Set back operation
0 (OFF)
0/1
1
—
06
Set back operation start time
23:00
0:00~23:00
1:00
hour
07
Set back operation stop time
5:00
0:00~23:00
1:00
hour
08
Leaving water set back value
2
0~10
1
°C
A
Quiet mode
00
Quiet mode type
0
0/2
—
—
01
Status
3
—
—
—
02
Not applicable. Do not change the default value.
1
Read only
—
—
03
Not applicable. Do not change the default value.
0
Read only
—
—
04
Not applicable. Do not change the default value.
0
Read only
—
—
b
Not applicable
00
Not applicable. Do not change the default value.
0
Read only
—
—
01
Not applicable. Do not change the default value.
0
Read only
—
—
02
Not applicable. Do not change the default value.
0
Read only
—
—
03
Not applicable. Do not change the default value.
0
Read only
—
—
04
Not applicable. Do not change the default value.
0
Read only
—
—
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range
Step
Unit
Date
Value
Date
Value