24
PIM00504
CAUTION
Do not hoist or move the product while there is oil in the tank. This could impair safety and/or
performance due to the product falling or toppling, or oil leakage or inclusion of air.
This product is precision equipment. Do not drop it or subject it to any strong impact.
Otherwise, there is a risk of breakage.
When transporting the product, do not hold wire harnesses, piping, solenoid valves, etc.
Otherwise, there is a risk of accidents due to breakage and falling.
Fix the product firmly so that it will not move due to vibration or external forces during
transportation.
7.2 Installation
7.2.1 Secure the space for air intake/exhaust
Install the unit at a well ventilated location where heat will not build up, and secure a surrounding space of
10 cm from each of the four end faces of the unit. Also take care that the temperature of the intake air
complies with the stipulated ambient temperature (40
°
C max.).
WARNING
If the intake air/exhaust spaces described above are not secured, the heat exchange function
of the oil cooler/DC fan will deteriorate, and the oil temperature and temperature of the
hydraulic devices will become abnormally high, posing a risk of fire. Be sure to secure the
space for air intake /exhaust.
Touching hot parts can cause burns.
Provide sufficient maintenance space so that working postures will not be uncomfortable.
Exhaust
At least
10 cm
At least 10 cm
Intake Air
Intake Air
At least
10 cm
Intake
Air
At least 10 cm