E(D/B)(H/L)Q011~016BB
Unit for air to water heat pump system
4PW67904-1 – 01.2011
Installation manual
54
14. T
ECHNICAL
SPECIFICATIONS
14.1. General
14.2. Electrical specifications
J8
Liquid pipe thermistor failure
Contact your local dealer.
L4
Electric component failure
Contact your local dealer.
L5
Electric component failure
Contact your local dealer.
L8
Electric component failure
Contact your local dealer.
L9
Electric component failure
Contact your local dealer.
LC
Electric component failure
Contact your local dealer.
P1
PCB failure
Contact your local dealer.
P4
Electric component failure
Contact your local dealer.
PJ
Failure of capacity setting
Contact your local dealer.
U0
Refrigerant failure (due to
refrigerant leak)
Contact your local dealer.
U1
Power supply cables are
connected in the reverse phase
instead of the normal phase.
Connect the power supply
cables in normal phase. Change
any two of the three power
supply cables (L1, L2, L3) to
correct phase.
U2
Main circuit voltage failure
Contact your local dealer.
U3
Underfloor heating screed
dry-out program has been
stopped by another error, or by
pushing operation off button, or
by power failure.
The error can only be reset in
the test mode as follows:
First, press the
z
button 4 times
so the
t
icon will be
displayed. Then press the
y
button 1 time. Finally push the
z
button to exit the test mode.
Notes:
• In this case [F-09] "Latest
action number executed" will
contain the latest action
number executed.
• [F-08] "Underfloor heating
screed dry-out program
enabled (1)/disabled (0)" is
always cleared to 0 (disable).
This means that in case a
second time a "Underfloor
heating screed dry-out
program" must be started,
[F-08] needs to be set again.
U4
Communication failure
Contact your local dealer.
U5
Communication failure
Contact your local dealer.
U7
Communication failure
Contact your local dealer.
UA
Communication failure
Contact your local dealer.
Error
code
Failure cause
Corrective action
EDLQ
EDHQ
EBLQ
EBHQ
Nominal capacity
• heating
Refer to the Technical Data
• cooling
Refer to the Technical Data
Dimensions H x W x D
1418 x 1435 x 382 mm
Weight
• machine weight
180 kg
• operation weight
185 kg
Connections
• water inlet/outlet
G 5/4" FBSP
(a)
(a) FBSP = Female British Standard Pipe
• water drain
hose nipple
Expansion vessel
• volume
10 l
• maximum working
pressure (MWP)
3 bar
Pump
• type
water cooled
• no. of speed
2
Internal water volume
5.5 l
Pressure relief valve
water circuit
3 bar
Operation range - water side
• heating
+15~+55°C
+15~+55°C
• cooling
—
+5~+22°C
Operation range - air side
• heating
–15~+35°C
(b)
(b) EDL and EBL models can reach –20°C / EDL_W1 and EBL_W1 models can
reach –25°C, but this is without capacity guarantee
–15~+35°C
(b)
• cooling
—
+10~+46°C
• domestic hot water by
heat pump
–15~+35°C
(b)
–15~+35°C
(b)
V3 models (1N~)
W1 models (3N~)
Standard unit (power supply via unit)
• power supply
230 V 50 Hz 1P
400 V 50 Hz 3P
• nominal running current
—
5.8 A
Backup heater
• power supply
See
"Connection of the backup heater power
supply" on page 24
• maximum running current
See
"Connection of the backup heater power
supply" on page 24