3 Operation

Operation manual

7

EHBH/X04~16CB + EHVH/X04~16CB
Daikin Altherma – Low temperature split
4P383117­1C – 2015.01

3.7

Menu structure: Overview user settings

< >

[1]

[2]

[5]

[6]

[7]

[2]

[6.2]

[6.3]

[6.8]

[7.1]

[7.4]

[7.3]

[3]

[4]

Set time/date

Date
Time
Daylight Saving Time
Clock type

Holiday

Holiday

Holiday

Holiday

Holiday mode

Holiday mode

Home

Away

From

Until

Until

From

Use day schedule

Operation mode
Heating
Cooling

Quiet mode

Operation mode

Select schedules

Room temperature
LWT main
LWT additional
Tank temperature

Information

Sensor information
Energy metering
Error handling
User permission level
Actuators
Operation modes

Running hours
Version

Energy metering

Consumed elec.

Produced energy

Error information

Error history

Contact/helpdesk number

Version

User interface

Indoor unit
Outdoor unit

User settings

Display

Temperature lock
Set schedules
Preset values
Allowed operation mode
Unit of measurement

Display

Contrast

Backlit LCD time
User profile
Available home pages

Set schedules

Room temp.
LWT main
LWT additional
DHW temp
Booster heater permission
Quiet mode

DHW pump

Preset values

Room temperature
LWT main
Tank temperature
Quiet level

DHW

Set weather dependent

Warning history

[7.7]

Set weather dependent

Main
Additional

[7.7.1] Main

Set weather-dependent heating

Set weather-dependent cooling

[7.7.2] Additional

Set weather-dependent heating

Set weather-dependent cooling

Summary of Contents for EHBH04CB

Page 1: ...Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHVH04S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB EHVH11S26CB EHVH16S18CB EHVH16S26CB EHVX0...

Page 2: ...es If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Documen...

Page 3: ...AVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Sw...

Page 4: ...guide User profile Basic User profile Detailed 15 20 20 0 C Mon Room Actual temperature 15 20 20 0 C 17 30 Actual temperature Room Scheduled Mon Tue To read out the actual and desired room temperatur...

Page 5: ...profile the user interface gives you either a basic or a detailed home page The examples in the illustrations below are in DHW tank mode Scheduled User profile Basic User profile Detailed 15 20 60 C...

Page 6: ...for Monday 1 Use and to select Monday 2 Press to enter the schedule for Monday 3 Program the schedule for Monday Use and to select an entry Use and to change the value of an entry To copy from one da...

Page 7: ...ctuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit Use...

Page 8: ...1 7 Emitter type 1 Slow 3 8 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled only Maximum setpoint Depends on model INFORMATION There is a risk of space heating cooling capac...

Page 9: ...vent gases into the atmosphere Refrigerant type R410A Global warming potential value 1975 Periodical inspections for refrigerant leaks may be required depending on the applicable legislation Please co...

Page 10: ...g operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the backup heater can take over the heat load or not When the heat pump fails will appe...

Page 11: ......

Page 12: ...4P383117 1 C 0000000 4P383117 1C 2015 01 Copyright 2014 Daikin...

Reviews: