4 Energy saving tips

Operation manual

8

EHBH/X04~16CB + EHVH/X04~16CB

Daikin Altherma – Low temperature split

4P383117­1C – 2015.01

INFORMATION

Depending  on  the  selected  installer  settings,  settings  will
be visible/invisible.

3.8

Installer settings: Tables to be
filled in by installer

3.8.1

Quick wizard

Setting

Default

Fill in…

Backup heater configuration (only for unified backup heater)
[A.2.1.5]

BUH type

1 (1P,(1/2))

Preferential kWh rate power supply [A.2.1.6]

Preferential kWh rate

0 (No)

Space heating/cooling settings [A.2.1]

Unit control method

2 (RT control)

User interface location

1 (In room)

Number of LWT zones

1 (1 LWT zone)

Pump operation mode

1 (Sample)

Domestic hot water settings [A.2.2]

DHW operation

Depends on
model

DHW tank type

Depends on
model

DHW pump

0 (No)

Thermostats [A.2.2]

Contact type main

2 (Thermo ON/
OFF)

Contact type add.

2 (Thermo ON/
OFF)

External sensor

0 (No)

Digital I/O PCB [A.2.2.6]

Ext. backup heat src

0 (No)

Solar kit

0 (No)

Alarm output

0 (Normally open)

Bottom plate heater

0 (No)

Demand PCB [A.2.2.7]

Demand PCB

0 (No)

Energy metering [A.2.2]

External kWh meter 1

0 (No)

External kWh meter 2

0 (No)

Capacities (energy metering) [A.2.3]

Booster heater

0 kW

BUH: step 1

Depends on
model

BUH: step 2

Depends on
model

Bottom plate heater

0 W

3.8.2

Space heating/cooling control

Setting

Default

Fill in…

Leaving water temperature: Main zone [A.3.1.1]

LWT setpoint mode

1 (WD)

Leaving water temperature: Additional zone [A.3.1.2]

LWT setpoint mode

1 (WD)

Leaving water temperature: Delta T source [A.3.1.3]

Setting

Default

Fill in…

Heating

5°C

Cooling

5°C

Leaving water temperature: Modulation [A.3.1.1.5]

Modulated LWT

0 (No)

Leaving water temperature: Emitter type [A.3.1.1.7]

Emitter type

1 (Slow)

3.8.3

Domestic hot water control [A.4]

Setting

Default

Fill in…

Type

2 (Scheduled
only)

Maximum setpoint

Depends on
model

INFORMATION

There  is  a  risk  of  space  heating  (cooling)  capacity
shortage/comfort problem (in case of frequent domestic hot
water  operation,  frequent  and  long  space  heating/cooling
interruption  will  happen)  when  selecting  [6­0D]=0  ([A.4.1]
Domestic  hot  water  Type=Reheat  only)  in  case  of  a
domestic hot water tank without an internal booster heater.

INFORMATION

When  the  DHW  tank  booster  mode  is  active,  the  risk  of
space  heating/cooling  and  capacity  shortage  comfort
problems  is  significant.  In  case  of  frequent  domestic  hot
water  operation,  frequent  and  long  space  heating/cooling
interruptions will happen.

3.8.4

Contact/helpdesk number [6.3.2]

Setting

Default

Fill in…

Contact/helpdesk number

4

Energy saving tips

Tips about room temperature

▪ Make  sure  the  desired  room  temperature  is  NEVER  too  high  (in

heating  mode)  or  too  low  (in  cooling  mode),  but  ALWAYS
according  to  your  actual  needs.  Each  saved  degree  can  save  up
to 6% of heating/cooling costs.

▪ Do  NOT  increase  the  desired  room  temperature  to  speed  up

space heating. The space will NOT heat up faster.

▪ When  your  system  layout  contains  slow  heat  emitters  (example:

under  floor  heating),  avoid  large  fluctuation  of  the  desired  room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.

▪ Use  a  weekly  schedule  for  your  normal  space  heating  or  cooling

needs. If necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature. 

Example: 

When  you  have  a  party,  or  when  you

are leaving for a couple of hours.

▪ For  longer  periods:  You  can  use  the  holiday  mode. 

Example:

When  you  stay  at  home  during  your  holiday,  or  when  you  go
away during your holiday.

Summary of Contents for EHBH04CB

Page 1: ...Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHVH04S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB EHVH11S26CB EHVH16S18CB EHVH16S26CB EHVX0...

Page 2: ...es If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Documen...

Page 3: ...AVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Sw...

Page 4: ...guide User profile Basic User profile Detailed 15 20 20 0 C Mon Room Actual temperature 15 20 20 0 C 17 30 Actual temperature Room Scheduled Mon Tue To read out the actual and desired room temperatur...

Page 5: ...profile the user interface gives you either a basic or a detailed home page The examples in the illustrations below are in DHW tank mode Scheduled User profile Basic User profile Detailed 15 20 60 C...

Page 6: ...for Monday 1 Use and to select Monday 2 Press to enter the schedule for Monday 3 Program the schedule for Monday Use and to select an entry Use and to change the value of an entry To copy from one da...

Page 7: ...ctuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit Use...

Page 8: ...1 7 Emitter type 1 Slow 3 8 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled only Maximum setpoint Depends on model INFORMATION There is a risk of space heating cooling capac...

Page 9: ...vent gases into the atmosphere Refrigerant type R410A Global warming potential value 1975 Periodical inspections for refrigerant leaks may be required depending on the applicable legislation Please co...

Page 10: ...g operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the backup heater can take over the heat load or not When the heat pump fails will appe...

Page 11: ......

Page 12: ...4P383117 1 C 0000000 4P383117 1C 2015 01 Copyright 2014 Daikin...

Reviews: