3
Product description
Installation and maintenance instructions
10
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1444099_00 – 07/2018 – EN
Item
Designation
Item
Designation
9
Storage tank (polypropyl-
ene double walled jacket
with PUR hard foam heat
insulation)
34
Ball valve (heating cir-
cuit)
10
Filling and draining con-
nection or solar return
flow connection
35
Combined filling and
draining valve (heating
circuit)
11
Mount for solar controller
or handle
37
t
DHW1
,
t
DHW2
Storage tank temperature
sensor
12
Heat exchanger (stain-
less steel) for domestic
hot water heating
38
Connection for dia-
phragm expansion vessel
13
Heat exchanger (stain-
less steel) for storage
tank charging or heating
support
39
Control system housing
14
Heat exchanger (stain-
less steel) for pressur-
ised solar system storage
charging
3UVB
1
3-way switch valve (in-
ternal heat generator cir-
cuit)
15
Connection for optional
electrical backup heater
EKBUxx
3UV
DHW
3-way switch valve (hot
water/heating)
16
Solar - inflow layering
pipe
DS
Pressure sensor
17
Fill level indicator (tank
water)
FLS
FlowSensor
18
Optional: electric backup
heater (EKBUxx)
t
R
Return flow temperature
sensor
19
Submersible sensor
sleeve for storage tank
temperature sensor t
DHW1
and t
DHW2
t
V
Inflow temperature
sensor
20
Pressure-free storage
tank water
t
V, BH
Backup heater inflow
temperature sensor
21
Solar zone
RoCon
+ B1
Controller control panel
22
Hot water zone
EKS-
RPS4
Optional: Solar control
and pump unit
23
Safety overflow connec-
tion
MAG
Diaphragm expansion
vessel
24
Mount for handle
Tab. 3-1
Legend for
to
3.2
Function of the 3-way switch
valves
Fig. 3-7
3-way switch valve function