4
Set-up and installation
Installation and maintenance instructions
18
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1444099_00 – 07/2018 – EN
Fig. 4-17
Aligning the heating inflow and return flow upwards
2
Pull the two plug brackets off the connection couplings (
, item C).
3
Pull off the two connection couplings (
, item B).
Fig. 4-18
Hydraulic system plug connectors
4
, item A).
5
Pull off the sealing plug bracket (
6
, item E).
7
Turn the elbow (
, item H) 90° to the rear.
8
Pull the plug bracket off the manifold (
, item G).
9
Carefully pull the manifold (
, item F) so far backwards
out of its horizontal mounting that the retaining plate (
,
item A) can be pushed vertically in between.
Fig. 4-19
Heating inflow and return flow connections aligned to the
rear
10
Slide the retaining plate between the manifold and its horizontal
mounting and insert the manifold (
mounting through the middle hole of the retaining plate.
11
Secure the manifold with plug bracket (
mounting again.
12
Insert the two connection couplings (
, item B) into the
lateral mountings through the retaining plate.
13
Secure the two connection couplings with plug bracket (
14
Insert the sealing plug (
, item E) into the upper mount-
ing.
15
Secure the sealing plug with plug bracket (
, item D).
16
Cut out side openings in the thermal insulation (
item A) using a suitable tool.
Fig. 4-20
Cut-out in thermal insulation
4.4.8
Making the hood opening
1
With the heating inflow and return flow directed upwards: Cut the
hood along the perforation with a suitable tool.