4
Set-up and installation
Installation and maintenance instructions
13
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1444099_00 – 07/2018 – EN
5
8
7
,5
0
4
3
2
4
1
2
,5
1
4
7
,5
9
8
2
1
4
5
3
A
B
6
7
785
0
249
332,5
452,5
162,5
147,5
Fig. 4-4
Dimensions, top of the device - Type …04P50D/…
08P50D
Item
Designation
1
Solar - inflow
2
Cold water
3
Domestic hot water
4
Heating inflow
5
Heating return flow
6
Connection for refrigerant gas line
7
Connection for refrigerant fluid line
8
Solar – inflow (…Biv type only)
9
Solar – return flow (…Biv type only)
A
front
B
rear
Tab. 4-1
4.2
Transport and delivery
WARNING
The Daikin Altherma EHS(X/H) is top-heavy in the unfilled
state and could tip over during transport. That could put
persons in danger or damage the unit.
▪ Secure the Daikin Altherma EHS(X/H) well, transport
carefully, use the handles.
The Daikin Altherma EHS(X/H) is delivered on a pallet. All industrial
trucks, such as lifting trucks and forklift trucks, are suitable for trans-
porting it.
Scope of delivery
▪ Daikin Altherma EHS(X/H) (preassembled),
▪ Bag of accessories (see
),
▪ Document pack.
A
(2x)
B
(3x)
C
(1x)
D
(1x)
E
(2x)
H
(2x)
F
(2x)
G
(1x)
I
(1x)
J
(1x)
K
(1x)
L
(1x)
Fig. 4-5
Contents of bag of accessories
Item
Designation
Item
Designation
A
Handles (only required
for transport)
G
O-ring
B
cover panel
H
Cable tie
C
Hose connecting piece
for safety overflow
I
Plug bracket
D
Assembly wrench
J
Venting hose
E
Ball valve
K
Drain hose cover
F
Flat gasket
L
RoConPlus controller
rotary switch
Tab. 4-2
For further accessories for the Daikin Altherma EHS(X/H), see Price
list.
4.3
Installing the heat pump
4.3.1
Selecting the installation site
CAUTION
If the total refrigerant charge in the system is ≥ 1.84 kg, it is
essential to comply with additional requirements for min-
imum footprint and minimum ventilation openings. Ob-
serve
Information on the total refrigerant charge can be found on
the type plate of the outdoor unit. Please follow the installa-