Panel indicatio Internal code
Contents
Remarks
Cause
E80
E10
Momentary over current alarm
Make the contact with the dealers.
E20
E20
DC low voltage
It may be input voltage drops, and the internal wiring breaks.
Confirm the wiring condition of power supply and a power
supply circumstance.
E30
E30
Pressure sensor system abnomal
It may be disconnection of pressure sensor and abreakage.
E80
E31
Encoder system abnomal
It may be unusual pump motor.
E40
E40
Motor thermo system abnomal
It may be the breakage or short of temperature sensor with in
motor.
E41
E41
Motor temperature abnomal rise
It may be the fan motor stop or clogged of radiator , etc.
Comfirm a radiator and fan.
E42
E42
Fin thermo system abnomal
It may be the breakage or short of temperature sensor with fin.
E43
E43
Fin temperature abnomal rise
It may be the fan motor stop or clogged of radiator , etc.
Comfirm a radiator and fan.
③
E62
E62
Pressure drop
Only alarm indication
When pressure decreased for more than 30 seconds
continuosly, P04="0" ( when pressure switch isn't set up), this
alarm isn't outputted.
-
E81
Retrial of momentary over current
Make the contact with the dealers.
-
E82
Retrial of encoder abnomal
Make the contact with the dealers.
-
E11
Over current
Make the contact with the dealers.
-
E21
DC over voltage
Make the contact with the dealers.
-
E42
Fin thermo system abnomal
It may be the breakage or short of temperature sensor with in
controller.
-
E43
Fin temperature abnomal rise
It may be controller abnomal.
⑥
E63
E63
Pressure switch operation
indication
Indicate when a pressure switch
operates. It isn't recorded as an
internal information
Cause pressure switch operation.
(When indication holding function is chosen by setting.
⑤
①
②
④
Unit stop
Unit stops after the setting time
progress.
Retrial occur in order to avoid
operation stop.
It is recorded as an internal
information.
Unit stops after the setting time
progress.
22
■
The indication list of alarm code.
The Eco Rich equipped with alarm detective function which classified as follows.
◆
Alarm code and abnormal phenomenon
Classification
①
Indicating alarm, at the same time, outputting alarm signal, then stopping operation forcibly.
Classification
②
Following actions are led by setting of setup mode item P02 (temperature alarm output setup) .
・
Setup value
『
0
』
: Not detect an alarm.
・
Setup value
『
1
』
: Indicating alarm and outputting alarm signal, then stopping operation forcibly 10 minutes
later. [Standard model : at sipping condition]
Classification
③
Following actions are led by setting of setup mode item P04 (pressure switch working pressure) .
(This alarm is pressure switch function.)
・
Setup value
『
0
』
: Not detect an alarm. [Standard model : at sipping condition]
・
Except setup value
『
0
』
: When the pressure decrease of setup time P03 (Delay time setup of pressure alarm)
continue, an alarm signal is outputting. It is canceled if the pressure reverts to the
normality. Operation is continued.
Classification
④
It is shown that there was “retrial action” to avoid operation stop in order not to stop the unit forcibly.
(Alarm code isn’t indicated.)
When it can’t be avoided, it is stopped forcibly, and alarm code
①
is indicated.
Classification
⑤
It is recorded only as an internal information.
Neither the stop of the unit nor the output of alarm signal.
Classification
⑥
Only when the item P04 (setup of pressure switch operation pressure) of the setup mode is effective,
and PO9 (setup of pressure switch operation indication holding) is “1”, alarm code is indicated.
However, alarm indication is held.