【INSTRUCTION MANUAL】
DAIKIN INDUSTRIES, LTD
.
SE-04430
【
10. Maintenance
】
To maintain motor pump performance for long term and fine, operate periodical maintenance about following item,
and if there is problem, perform repair or replacement.
An inspection time, period is shown as a standard on following table, it varies depends on the use condition,
environment, and so on.
23
■
Periodic inspection
Object/ item
Inspection time/period
Inspection principles
●
Oil tank
・
Confirmation of oil
amount
・
Confirmation of oil
temperature
・
Confirmation of oil
color
Daily
Daily
Once/6 months
Confirm float locates between red line and yellow line of oil
gauge. Confirm hydraulic oil becoming muddy and bubble
getting mixed.
Confirm that it is less than 60
°
.
It is possible to confirm deterioration of oil-hydraulic oil by
color. If recognize oil color changing to dark-brown
(
ASTM level 4
:
bright-yellow
)
, change hydraulic oil
●
Oil cooler
・
Fan motor rotation
・
Core part clogging
Daily
Once/6 months
Confirm fan motor rotation.
If the fan motor stop rotation,
①
The cooling function of oil-cooler declines remarkably.
Hydraulic oil or equipment becomes high temperature,
and there is fear of the burn. So that quickens
deterioration of hydraulic oil, and shortens the life of
equipment.
②
The motor becomes high temperature (the fan motor
cool the motor also), and shortens the life of the motor.
Confirm occurrence of core clogging by visual
observation.
If the core clogging, the cooling function of oil-cooler
declines. Hydraulic oil or equipment becomes high
temperature, and there is fear of the burn. So that
quickens deterioration of hydraulic oil, and shortens the life
of equipment.
●
Pressure indication
・
Operation confirmation
・
Indicated pressure
confirmation
Daily
Daily
Confirm the indication change as change of loading
condition.
Confirm pressure indication value of DH as it setup.
●
Noise
Daily
Confirm no abnormal noise.
●
Electric wiring
Once/ 6 months
①
Confirm no crack and damage in covering material of
wire.
②
Measure insulation resistance, and confirm to ground the
earth properly.
●
Hose
Once/ a year
Confirm no crack, damage and flaw.