background image

【INSTRUCTION MANUAL】

DAIKIN  INDUSTRIES,  LTD

.

SE-04430

Cleaning and change 

Object/item Operation 

time/period 

Operation principles 

Oil tank 

  ・

oil changing 

 

 
Once/ a year 

 
Change hydraulic oil periodically. 
Long time use of this hydraulic unit without changing oil may be 
harmful for operation and life of the hydraulic equipment. 

Oil cooler 

  ・

core cleaning 

Once/ a year 

Disassemble and clean, as following maintenance principle on 
page 25-26. 

Oil inlet port with air 

breather 

Once/ a year 

Disassemble and clean, as following maintenance principle on 
page 26. 

Suction strainer 

Once/ a year 

Disassemble and clean, as following maintenance principle on 
page 27. 

 

24

     

Danger

Do not touch rotary point.

When touching the inside of the controller, observe the process to prevent an electric shock.

 

i ) Turn off the main power source of the hydraulic unit.

  

(Turn off the power source breaker of the circuit supplying a power.)
Put a bill such as “Operation prohibited (Working)” on the power source breaker, and prevent wrong 
operation.

 ⅱ

)        ii) After more than 5 minutes pass, remove the cover of the terminal box.

As for the controller, do not remove except for the cover of the terminal box.

When starting operation, turn on electricity after installing all of the cover on the controller.

Summary of Contents for EHU Series

Page 1: ...ydraulics Division Photo EHU25 M07 AE 30 This instruction manual is based on these following types Eco Rich As for MGF NO before them there is some difference in operating manual of the panel and adju...

Page 2: ...e standard for safety operation or maintenance of your machine Symbols of safety precautions in this manual In this manual safety precautions are represented and classify 3 rank Danger Warning and Cau...

Page 3: ...uld exempt from any responsibilities Limitation of uses Make sure to consider the situation in case of life threatening owing to breakdown or wrong working of this machine or possibilities of danger t...

Page 4: ...Electric wiring 8 Test run 16 9 Operating manual of the control panel 18 23 General description Explanation of each mode Shift to each mode Operation manual of each mode 10 Maintenance 24 28 Attached...

Page 5: ...of the parts according to the improvement of quality performance and other circumstances 2 Nomenclature MFG NO a Series name EHU EHU Series b Max discharge flow rate of the pump 14 14 L min 25 25 L m...

Page 6: ...that s column of the initial setup value for a setup of alarm at sipping As for other specifications confirm a delivery specifications form drawings Note 1 Note 2 Note 3 Note 1 Note 2 Note 3 Working...

Page 7: ...tions for the non standard products Controller Unit name plate Notice name plate Oil inlet port with air breather Tank Sample port with drain cap Oil gauge Valve block Front view of the unit SR motor...

Page 8: ...ANUAL DAIKIN INDUSTRIES LTD SE 04430 Parts 5 Hydraulic circuit Hydraulic circuit Part NO Name 1 Tank 2 Suction filter 3 Oil gauge 4 Inverter driving pump 5 Oil inlet port with air breather 6 Oil coole...

Page 9: ...lt In this time move the unit carefully about balance so as not to be damaged the piping by the hook Eyebolt Detail of spacer 2 places Type Weight EHU14 L04 EHU25 L04 EHU25 L07 EHU25 M07 EHU30 M07 43k...

Page 10: ...e of touching high temperature part you may be burnt Caution When it is used in where there is no space of inhalation exhaust and heat place the motor becomes high temperature and the life of the moto...

Page 11: ...t the float of the oil gauge is between the red line and the yellow line Use the hydraulic oil appropriate to the specifications as it was mentioned in page 6 Drain port DR1 Rp1 Upper oil surface Disc...

Page 12: ...und earth terminal must be down to ground over the third class Connect it directly not to pass through the breaker Wire after installing the machine surely Be sure to turn off the breaker of the main...

Page 13: ...ow figure to connect with the terminal board 4 After wiring be sure to install the cover of the terminal box as it was Insert special driver or precision driver width 2 4 3mm as left figure Make sure...

Page 14: ...careful not to damage the conductor when stripping electric wire Use DC24V or DC12V minimum load current 10mA for alarm connection circuit Use AC100V 50 60Hz under alternative current control As for...

Page 15: ...a driver etc Make sure of stripped wire length and insert them until the end without separating Remove the driver from the lever Make sure of wiring by pulling the electric wire slightly How to connec...

Page 16: ...in plug Then fill fixed amount of flesh hydraulic oil to the oil inlet port with air breather Within NAS 10 class pure oil is used as flesh hydraulic oil Remove the air of hydraulic circuit completely...

Page 17: ...ce this hydraulic unit has CPU it is easy to monitor setup and adjust such as pressure flow by operation of key switch General description The control panel is composed of 3 digits LED mode key settin...

Page 18: ...ndicating a Monitor mode While monitor mode it is possible to monitor item on the table below by choice Operation example is shown as following Ex Monitor actual flow rate Operation manual of each mod...

Page 19: ...to the signal output Refer to att page11 for specifiscations of pressure switch output 7 0 P00 P01 P02 P03 P04 It is possible to indicate and setup the contact output of abnormal motor temperature ris...

Page 20: ...s later Changing setup value Setup value entry Light up item NO Example of operation principles of setup mode Adjusting max flow Ex Change max flow 25L min to 20 5L min Caution The change of the setup...

Page 21: ...latest one Changing setup mode Choosing record number Alarm content indication Another confirming 2 seconds later Indicate the latest alarm Indicate by turns in every 1 second Power ON number of times...

Page 22: ...n holding function is chosen by setting Unit stop Unit stops after the setting time progress Retrial occur in order to avoid operation stop It is recorded as an internal information Unit stops after t...

Page 23: ...ily Once 6 months Confirm fan motor rotation If the fan motor stop rotation The cooling function of oil cooler declines remarkably Hydraulic oil or equipment becomes high temperature and there is fear...

Page 24: ...e principle on page 26 Suction strainer Once a year Disassemble and clean as following maintenance principle on page 27 Danger Do not touch rotary point When touching the inside of the controller obse...

Page 25: ...strong power on power supply wire or connector of fan motor while operation Be careful of oil leakage from piping or oil cooler while disassembling 1 Removing the oil cooler When removing the cover o...

Page 26: ...embling completed Be careful to setup inhalation exhaust direction of oil cooler page 10 Oil inlet port with air breather maintenance principle 1 Removal It is easy to remove turn cap to the countercl...

Page 27: ...ove suction strainer 2 Cleaning Blow filter by air and blow sticking piling up material off Remove dust inside the cylinder of strainer 3 Reassembling After cleaning completed reassemble as it was Do...

Page 28: ...low control valve Note The valve block is different in working pressure When you have changed PC setup pressure refer to spare parts list or consult with our Sales Division Caution Be sure to change t...

Page 29: ...of the purpose Example When setup pressure is 1 5 MPa it marks 15 in case of 7 0 Mpa it marks 70 Confirm that O ring is attached to two holes at the bottom of the valve block Wipe both contact surfac...

Page 30: ...number of revolutions Loosen the lock nut of the flow control valve for adjustment of minimum number of revolutions Adjust the flow control valve with confirming the valve of the actual number of rev...

Page 31: ...ons to 350 min 1 Return to actual pressure indication Rotate adjustment screw of flow control valve to clockwise Set up adjustment screw Change to monitor mode Indication number of revolutions Operati...

Page 32: ...ons by the flow control valve Caution In case of using above 6 MPa of PC setup pressure and becoming unstable with influence such as contamination install a fixed flow control plug 0 8 In case of inst...

Page 33: ...ase of turning on after tightened the pressure adjustment screw it is dangerous that surge pressure causes 2 1 Changing process of PC setup pressure Fixed flow control plug 0 8 NPTF1 16 Section A A Lo...

Page 34: ...at PC control Since the number of revolutions increases by rising of setup pressure adjust to the proper number of revolutions Minimum number of rotation Number of rotation at the hold pressure befor...

Page 35: ...In case of installing the fixed flow control plug the number of revolutions don t increase An operation example is shown Example In case of adjusting the minimum number of revolutions to 350 min 1 Rot...

Page 36: ...mber of revolutions increases rapidly in the position where the relief valve acts Then turn tighten to the position where the number of rotation becomes the minimum number of revolutions 5 Tighten and...

Page 37: ...imum number of rotation and work in accordance with the process from attached document 5 page after the number of revolutions is raised about 600min Reference The pressure change of by the pressure ad...

Page 38: ...condition H Condition without alarm L Waiting H Operation ready Maximum 3 0 seconds Maximum 10 seconds Charge Positioning Normal control Actual pressure indication Actual pressure indication 1 3 With...

Page 39: ...canceled except for resetting power supply Alarm has been outputted soon in case the temperature is more than 105 at starting the power supply 105 Motor temperature Mode Alarm Indication Alarm count...

Page 40: ...is kept to indicate until ENT KEY is pushed It is also cleared with resetting power supply 4 2 After the retrial when alarm output Pressure Mode Alarm Indication H Condition without alarm L Alarm con...

Page 41: ...39 39 39 Additions and changes 37 3E 37 3E 3A 3F 3A 3F 3A 3F Addition of indication hold function 3F 3F 3G 3G 3G Addition of response gain setup function Addition of operation ready output function Ad...

Reviews: