【INSTRUCTION MANUAL】
DAIKIN INDUSTRIES, LTD
.
SE-04430
■
Suction strainer maintenance principle
1. Removal
①
Remove power source/alarm wire.
②
Remove the fan-cover.
(6 points of M5 truss screw)
(As “EHU**-L04” 4 points)
③
Remove the screw that fixes the upper board
with the tank.
(8 points of M5 truss screw)
④
Hung up the upper board and the controller to
separate from the tank.
⑤
As suction strainer can be seen, loosen and
remove suction strainer.
2. Cleaning
Blow filter by air, and blow sticking/piling up
material off.
Remove dust inside the cylinder of strainer.
3. Reassembling
After cleaning completed, reassemble as it was.
Do reverse work of the removal.
Confirm operation driven properly, as following
trial operation on page 16,after reassembling
completed.
◎
Truss screw
(8 places
)
◎
Fan cover
27
Warning
・
Wear protective glasses, while air blow operation, to prevent to get piled-ups or dust into the eye.
◎
Truss screw for tightening fan
cover (4 places
)
Common with
「
EHU**-L04,L07,07
」
◎
Truss screw for tightening
fan cover
only with
「