background image

3 Operation

Operation manual

6

EHVH04~26CB6W

Daikin Altherma – Low temperature split

4P449982-1 – 2016.06

3.5

Advanced usage

3.5.1

About changing the user permission level

The  amount  of  information  you  can  read  out  in  the  menu  structure
depends on your user permission level:

▪ End user (= default)

▪ Adv. end user: You can read out more information.

To set the user permission level to Advanced end user

1

Go to the main menu or any of its submenus: 

.

2

Press 

 for more than 4 seconds.

Result: 

The  user  permission  level  switches  to  Adv.  end  user.

Additional information is displayed and "+" is added to the menu title.
The  user  permission  level  will  stay  in  Adv.  end  user  until  set
otherwise.

To set the user permission level to End user

1

Press 

 for more than 4 seconds.

Result: 

The  user  permission  level  switches  to  End  user.  The  user

interface will return to the default home screen.

3.6

Schedules: Example

INFORMATION

The procedures to program other schedules are similar.

In this example:

▪ Room temperature schedule in heating mode

▪ Monday = Tuesday = Wednesday = Thursday = Friday

▪ Saturday = Sunday

To program the schedule

1

Go  to  [7.3.1.1]: 

  >  User  settings  >  Set  schedules  >  Room

temp. > Set heating schedule.

2

Select Empty and press 

.

3

Program the schedule for Monday. See below for more details.

4

Copy  from  Monday  to  Tuesday,  Wednesday,  Thursday  and
Friday. See below for more details.

5

Program the schedule for Saturday.

6

Copy from Saturday to Sunday.

7

Save  the  schedule  and  give  it  a  name.  See  below  for  more
details.

To program the schedule for Monday

1

Use 

 and 

 to select Monday.

2

Press 

 to enter the schedule for Monday.

3

Program the schedule for Monday:

▪ Use 

 and 

 to select an entry.

▪ Use 

 and 

 to change the value of an entry.

To copy from one day to another

1

Select  the  day  from  which  you  want  to  copy  and  press 

.

Example: 

Monday.

2

Select Copy day and press 

.

3

Set the days you want to copy to Yes and press 

Example:

Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday
= Yes.

To save the schedule

1

Press 

, select Save schedule and press 

.

2

Select  User  defined  1,  User  defined  2  or  User  defined  3  and
press 

.

3

Change  the  name  and  press 

.  (Only  applicable  for  room

temperature schedules). 

Example: 

MyWeekSchedule

To select which schedule you currently want to use

1

Go to [5]: 

 > Select schedules.

2

Select for which control you want to use a schedule. 

Example:

[5.1] Room temperature.

3

Select  for  which  operation  mode  you  want  to  use  a  schedule.

Example: 

[5.1.1] Heating.

4

Select a predefined or user‑defined schedule and press 

.

Summary of Contents for EHVH04SU18CB6W

Page 1: ...Operation manual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHVH04SU18CB6W EHVH08SU18CB6W EHVH08SU26CB6W EHVH11SU26CB6W EHVH16SU26CB6W...

Page 2: ...document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you...

Page 3: ...er interface at a glance 3 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home page Goes to the default home page when you are in the menu structure b MALFUNCTION I...

Page 4: ...trol Using the room temperature home page Typical room temperature home pages Depending on the user profile the user interface gives you either a basic or a detailed home page To set the user profile...

Page 5: ...ed mode However when the DHW tank temperature drops below a preset value reheat tank temperature hysteresis value example 35 C the DHW tank heats up until it reaches the reheat set point example 45 C...

Page 6: ...schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below fo...

Page 7: ...Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Tempe...

Page 8: ...3 Booster heater 2 4 kW BUH step 1 3 kW BUH step 2 3 kW Bottom plate heater 0 W 3 8 2 Space heating control Setting Default Fill in Leaving water temperature Main zone A 3 1 1 LWT setpoint mode 1 WD L...

Page 9: ...ght is not sufficient program to additionally heat up the DHW tank to a preset value Storage eco lower DHW tank temperature during the day Make sure the desired DHW tank temperature is NOT too high Ex...

Page 10: ...set value Storage eco lower tank temperature during the day The desired DHW tank temperature is too low 6 3 Symptom Heat pump failure When the heat pump fails to operate the backup heater and booster...

Page 11: ......

Page 12: ...4P449982 1 0000000Y 4P449982 1 2016 06 Copyright 2016 Daikin...