Installer reference guide
81
EHVH/X16
Daikin Altherma - Low Temperature Split
4P313777-1 – 2012.05
14 Technical data
4D079038 page 3
450
400
350
300
250
200
150
Ve
q 40°C [l]
1,55
1,77
2,19
1,38
1,91
150l
200l
300l
EKHWS*
EHV*
180l
260l
40
42
44
46
48
50
52
54
56
58
60
EHV*S18CA*
EHV*S26CA*
Medium tapping pattern EN16147 (= 2 persons)
Large tapping pattern EN16147 (= 3~4 persons)
Heat loss of domestic hot water tank (4)
Selection guidance of domestic hot water tank volume (3)
T
a
nk temperature (°C)
Heat loss [kWh/24h]
Notes:
(2)
T
ime required to heat up the tank starting from a temp of 10°C up to the indicated temp with the
heatpump only
.
(3)
According to EN16147
(4)
According to EN12897
If a higher daily V
eq 40°C is required then additional heat up cycles are required within 24 hours. Refer to the operation manu
al for more information.
T
ank
Heat loss [kWh/24h]
Ta
n
k
V
eq 40°C = amount of water that can be tapped with a temperature of 40°C when the hot water tank is heated till a certain tempe
rature with a cold water inlet temperature of 10°C.
The 40°C is considered as a comfrotable domestic hot water temperature.